[. . . ] When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye (emitter with an amber indicator light) transmits an invisible light beam to the receiving eye (receiver with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position. The units must be installed inside the garage so that the sending (emitting)and receiving eyes face each other across the door, no more than 6" (15 cm) above the floor. [. . . ] Tighten the nuts securely.
1/4"-20 Lock Nuts
"C" Wrap Mounting Bracket with Slot Mounting Bracket with Square Holes
Figure 3 DOOR Track Installation Door Track Installation Procedure
· Discard slotted bracket. Drill 3/8" holes in each track and fasten securely with hardware (Figure 3).
Inside Wall Door Track 1/4" Lock Nuts Mounting Bracket with Square Holes
Drill 3/8" Holes "C" Shaped Wrap 1/4-20x1/2" Carriage Bolts
HARDWARE SHOWN ACTUAL SIZE
Screw #10-32x3/8"
Lock Nut #10x32
Lag Screw 1/4x1-1/2" Staples
Carriage Bolts 1/4"-20x1/2"
Lock Nut 1/4"-20
Figure 4 Alternate Wall Mount
Inside Wall Mounting Bracket with Slot Mounting Bracket with Square Holes "C" Wrap Sensor with wire Indicator Light Floor
Figure 5 Alternate Floor Mount
Inside Wall Sensor with wire Indicator Light Mounting Bracket with Square Holes Mounting Bracket with Slot Attach with concrete anchors (not provided)
"C" Wrap
Floor
2
Bell Wire
Secure Wire with Insulated Staples
Connect Wire to Commercial Protector Interface
Safety Sensor Beam 6" (15 cm) max. above floor
Invisible Light Beam Protection Area
Safety Sensor Beam 6" (15 cm) max. above floor
MOUNTING AND WIRING THE SAFETY SENSORS
· Insert the wire connector into each sensor and push until you hear a click. The white tab on the sensor should be flush with the back of connector. · Center each sensor unit in a "C" wrap with lenses pointing toward each other across the door. · Secure sensors with hardware as shown. Finger tighten the wing nut on the receiving eye to allow for final adjustment. Securely tighten the sending eye wing nut. · Run paired wires from both sensors to the opener (Figure 6). Use insulated staples to secure the wire to the wall and ceiling. · For wiring connections, see following pages: CPS page 4 CPS-L page 4 CPSII page 5
Sensor
Figure 6
Wing Nut "C" Wrap Wire
Indicator Light
1/4-20 x 1-1/2" Hex Bolt
HARDWARE SHOWN ACTUAL SIZE 1/4-20x1-1/2" Hex Bolt Wing Nut
ALIGNING THE SAFETY SENSORS
· Power up the opener. Green indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. If the receiving eye indicator light is not glowing steadily (and the invisible light beam path is not obstructed), alignment is required. · Loosen the receiving eye wing nut to allow slight rotation of unit. Adjust sensor vertically and/or horizontally until the green indicator light glows steadily. · When indicator lights are glowing steadily in both units, tighten the wing nut in the receiving eye unit.
3
CPS Wiring Connections
Commercial Protector Interface 24V
Common CDO Sensing Edge Input Sensor White To Sending Eye (Emitter) and Receiving Eye (Receiver) Sensor White/Black
WARNING CPS-L Wiring Connections for use with Solid State II (Logic Control Board Ver 2) CAUTION
Once eyes are connected it will be necessary to set DIP switch to Timer to Close mode (refer to "Activate Photo Eyes" instructions below).
Logic 2 Shown
White White/Black
TO ACTIVATE SAFETY SENSOR EYES
1. Set DIP switch on logic board to "Set Timer to Close" mode. If using "Timer to Close, " set delay time now. Set DIP switch back to desired operating mode. [. . . ] NOTE: For non-solid state operators, if the door is stopped in a mid position, activation of the sensors will cause the door to open. This is similar to activating a sensor edge. CPS-L Only: If the sending eye and receiving eye indicator lights are both lit but interrupting the photo eyes does not cause the door to reverse when closing, refer to "To Activate Safety Sensor Eyes" on page 4.
6
Replacement Parts
CPS CPSII Commercial Protector Interface . . 001A5053-9
CPS / CPSII / CPS-L
How to Order Repair Parts
Our large service organization spans America. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CPSII
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.