User manual LIFT-MASTER EH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER EH. We hope that this LIFT-MASTER EH user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER EH.


Mode d'emploi LIFT-MASTER EH
Download
Manual abstract: user guide LIFT-MASTER EH

Detailed instructions for use are in the User's Guide.

[. . . ] LO OWNER'S MANUAL MODELS: L IC G CO N TR O L FACTORY SET EJ & EH LOGIC CONTROL (VER. 2. 0) INDUSTRIAL DUTY DOOR OPERATOR C2 Wiring See pages 16 & 17 for other wiring configurations 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type IMPORTANT SAFETY NOTES Before attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. These safety alert symbols mean Caution ­ a personal safety or property damage instruction. This door opener is designed and tested to offer reasonable safe service provided it is installed and operated in strict accordance with the following safety rules. Failure to comply with the following instructions may result in serious personal injury or property damage. Keep door balanced. [. . . ] For Control Station and Main/ Emergency Disconnect mounting refer to figure 10 below. 40-10033B 2. Use same conduit entry into the electrical box as the power wiring. FIGURE 10 MOUNTING INSTRUCTIONS 1. Mount Control Station and Main/ Emergency Disconnect no further than 305mm (12") from each other. Mount Control Station and Main/ Emergency Disconnect no further than 305mm (12") from the door enclosure. ANY MAINTENANCE OTHER THAN PROGRAMMING OPTIONS IN THE OPERATOR OR IN THE AREA NEAR THE OPERATOR MUST NOT BE PERFORMED UNTIL DISCONNECTING THE ELECTRICAL POWER AND LOCKING-OUT THE POWER VIA, THE MAIN DISCONNECT SWITCH. UPON COMPLETION OF MAINTENANCE THE AREA MUST BE CLEARED AND SECURED, AT THAT TIME THE UNIT MAY BE RETURNED TO SERVICE. 3. Mount WARNING NOTICE beside or below the Control Station and Main/ Disconnect. Mount MAINTENANCE ALERT label to either side of control station. Control Station Main Disconnect 4 ft. (1219mm) (Approximate) Maintenance Alert SystemTM If light is Flashing, it is time for routine Door and Opener Maintenance. If light is Steady On, call for immediate service. Service every ________ cycles. 11 LOGIC CONTROL (VER. 2. 0) 1 PH WIRING SCHEMATIC AUXILIARY CLOSE LIMIT SWITCH 125/24VAC 10 A (YE) (WH) 1874-1 OPEN LIMIT SWITCH 125/24VAC 10 A RADIO (24V) R1 R2 R3 TO RPM SENSOR (BL) (WH) CLOSE LIMIT SWITCH 125/24VAC 10 A (RD) (WH) (WH) 5V (WH) N (BR) N (GY/WH) N (YE) 28V (GY) (YE) (RD) 5V NN 3 2 4 1 1 2 3 4 43 2 1 E13 (YE) P4 P5 P6 E12 E4 (BK) 230V POWER PHASE JUMPER IN 1PH POSITION SINGLE PHASE E17 CONTACTOR/ 3 PHASE E15 (YE) N TO MOTOR (1/2HP 230V/50HZ 1PH) (BL) 230V (OR) E10 (BL/BK) 230V (RD) BRAKE SOLENOID (240V) E2 E5 E1 (BL/BK) N 1 BUTTON STATION (OPTIONAL) (BK) 230V SENSING DEVICE OVERLOAD (250VAC 32VDC 6A) E11 (BK) N TB1 1 2 3 4 5 6 7 8 9 10 11 12 13 E14 E19 E9 L3 L2 L1 (YE) INTER. SWITCH (YE) N (OR) N (BK) 230V (GN/YE) (GN/YE) (BK) N (RD) 230V N1 P1 LINE FILTER (250VAC 10A) SECONDARY PRIMARY (YE) 24VAC E N (BK) N P (RD) 230V STOP 3 BUTTON STATION (5V) CLOSE TRANSFORMER (240VAC PRIMARY 24VAC SECONDARY 50/60HZ 40VA) L3 L2 (BK) N L1 (RD) 230V TERMINAL BLOCK (600V) OPEN MAIN/ EMERGENCY DISCONNECT (600VAC 16A) EMERGENCY STOP KEY SWITCH (OPTIONAL) PE MAINTENACE ALERT LED N L1 FUSED POWER IN (230V 50HZ 1PH) 12 ELECTRICAL BOX COMPONENT LOCATION The operator electrical box is only to be accessed by trained "LIFTMASTER" technicians. If service is required contact your local LIFTMASTER dealer. WARNING HIGH VOLTAGE COVER 40-16307A HIGH VOLTAGE COVER LABEL TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRICAL POWER AND LOCK-OUT POWER VIA, MAIN DISCONNECT SWITCH BEFORE REMOVING COVER. CAPTIVE TERMINAL BLOCK 230V/50Hz 1PH TB1 TERMINAL BLOCK PRINTED CIRCUIT BOARD GROUND SCREW 13 LIMIT SWITCH ADJUSTMENT The operator electrical box is only to be accessed by trained "LIFTMASTER" technicians. If service is required contact your local LIFTMASTER dealer. MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. (Limit switch adjustments are located on the front wall of the electrical enclosure, see figure below) 1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. WA FIGURE 11 WHEN ORDERING REPAIR PARTS AND ACCESSORIES ADDRESS ORDER TO: CHAMBERLAIN GmbH Alfred-Nobel-Str. 4 66793 Saarwellingen PHONE ORDER: FAX ORDER: (49) 6838-907105 (49) 6838-907239 TECHNICAL HOTLINE: (49) 6838-907171 CAUTION OPEN LIMIT SW. DEPRESS PLATE CLOSE LIMIT SW. ROTATOR CUP LIMIT NUT RPM BOARD SAFETY LIMIT SW. CUT-AWAY VIEW OF ELECTRICAL BOX 14 PROGRAM SETTINGS Logic Control Pushbuttons Open, Close, Stop Open, Close and Stop buttons are mounted directly on the Logic Control board. [. . . ] Check at the intervals listed in the following chart. ITEM Drive Chain PROCEDURE Check for excessive slack. Lubricate Check set screw tightness Check & adjust as required Check condition & tension Check & tighten as required Check for wear & Lubricate EVERY 3 MONTHS OR 5, 000 CYCLES EVERY 6 MONTHS OR 10, 000 CYCLES EVERY 12 MONTHS OR 20, 000 CYCLES Sprockets Clutch Belt Fasteners Manual Disconnect Check & Operate Bearings & Shafts Use SAE 30 Oil (Never use grease or silicone spray). Motor bearings are rated for continuous operation. Inspect and service whenever a malfunction is observed or suspected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER EH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER EH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag