LOGIC CONTROL (VER. 2. 0) INDUSTRIAL DUTY DOOR OPERATOR
C2 Wiring
See pages 16 & 17 for other wiring configurations
2 YEAR WARRANTY
Serial # (located on electrical box cover) Installation Date Wiring Type
IMPORTANT SAFETY NOTES Before attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
These safety alert symbols mean Caution a personal safety or property damage instruction. This door opener is designed and tested to offer reasonable safe service provided it is installed and operated in strict accordance with the following safety rules. Failure to comply with the following instructions may result in serious personal injury or property damage.
Keep door balanced. [. . . ] For Control Station and Main/ Emergency Disconnect mounting refer to figure 10 below.
40-10033B
2. Use same conduit entry into the electrical box as the power wiring.
FIGURE 10 MOUNTING INSTRUCTIONS
1. Mount Control Station and Main/ Emergency Disconnect no further than 305mm (12") from each other. Mount Control Station and Main/ Emergency Disconnect no further than 305mm (12") from the door enclosure.
ANY MAINTENANCE OTHER THAN PROGRAMMING OPTIONS IN THE OPERATOR OR IN THE AREA NEAR THE OPERATOR MUST NOT BE PERFORMED UNTIL DISCONNECTING THE ELECTRICAL POWER AND LOCKING-OUT THE POWER VIA, THE MAIN DISCONNECT SWITCH. UPON COMPLETION OF MAINTENANCE THE AREA MUST BE CLEARED AND SECURED, AT THAT TIME THE UNIT MAY BE RETURNED TO SERVICE.
3. Mount WARNING NOTICE beside or below the Control Station and Main/ Disconnect. Mount MAINTENANCE ALERT label to either side of control station.
Control Station Main Disconnect 4 ft. (1219mm) (Approximate)
Maintenance Alert SystemTM If light is Flashing, it is time for routine Door and Opener Maintenance. If light is Steady On, call for immediate service.
Service every ________ cycles.
11
LOGIC CONTROL (VER. 2. 0) 1 PH WIRING SCHEMATIC
AUXILIARY CLOSE LIMIT SWITCH 125/24VAC 10 A
(YE) (WH)
1874-1
OPEN LIMIT SWITCH 125/24VAC 10 A RADIO (24V) R1 R2 R3 TO RPM SENSOR
(BL) (WH)
CLOSE LIMIT SWITCH 125/24VAC 10 A
(RD) (WH) (WH) 5V (WH) N
(BR) N
(GY/WH) N
(YE) 28V
(GY) (YE) (RD) 5V NN
3
2
4
1
1
2
3
4
43
2
1
E13
(YE)
P4
P5
P6 E12 E4
(BK) 230V
POWER PHASE JUMPER IN 1PH POSITION SINGLE PHASE
E17
CONTACTOR/ 3 PHASE
E15
(YE) N
TO MOTOR (1/2HP 230V/50HZ 1PH)
(BL) 230V (OR)
E10
(BL/BK) 230V (RD)
BRAKE SOLENOID (240V)
E2
E5 E1
(BL/BK) N
1 BUTTON STATION (OPTIONAL)
(BK) 230V
SENSING DEVICE
OVERLOAD (250VAC 32VDC 6A)
E11
(BK) N
TB1
1
2
3
4
5
6
7
8
9 10 11 12 13 E14 E19 E9
L3
L2
L1
(YE) INTER. SWITCH
(YE) N
(OR) N
(BK) 230V
(GN/YE)
(GN/YE)
(BK) N
(RD) 230V
N1 P1 LINE FILTER (250VAC 10A)
SECONDARY
PRIMARY
(YE) 24VAC
E
N (BK) N
P (RD) 230V
STOP
3 BUTTON STATION (5V)
CLOSE
TRANSFORMER (240VAC PRIMARY 24VAC SECONDARY 50/60HZ 40VA)
L3
L2
(BK) N
L1
(RD) 230V
TERMINAL BLOCK (600V)
OPEN MAIN/ EMERGENCY DISCONNECT (600VAC 16A)
EMERGENCY STOP
KEY SWITCH (OPTIONAL)
PE
MAINTENACE ALERT LED
N
L1
FUSED POWER IN (230V 50HZ 1PH)
12
ELECTRICAL BOX COMPONENT LOCATION
The operator electrical box is only to be accessed by trained "LIFTMASTER" technicians. If service is required contact your local LIFTMASTER dealer.
WARNING
HIGH VOLTAGE COVER
40-16307A
HIGH VOLTAGE COVER LABEL
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRICAL POWER AND LOCK-OUT POWER VIA, MAIN DISCONNECT SWITCH BEFORE REMOVING COVER.
CAPTIVE TERMINAL BLOCK 230V/50Hz 1PH
TB1 TERMINAL BLOCK
PRINTED CIRCUIT BOARD
GROUND SCREW
13
LIMIT SWITCH ADJUSTMENT
The operator electrical box is only to be accessed by trained "LIFTMASTER" technicians. If service is required contact your local LIFTMASTER dealer.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. (Limit switch adjustments are located on the front wall of the electrical enclosure, see figure below) 1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor.
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
WA
FIGURE 11
WHEN ORDERING REPAIR PARTS AND ACCESSORIES ADDRESS ORDER TO: CHAMBERLAIN GmbH Alfred-Nobel-Str. 4 66793 Saarwellingen PHONE ORDER: FAX ORDER: (49) 6838-907105 (49) 6838-907239 TECHNICAL HOTLINE: (49) 6838-907171
CAUTION
OPEN LIMIT SW.
DEPRESS PLATE
CLOSE LIMIT SW. ROTATOR CUP
LIMIT NUT
RPM BOARD SAFETY LIMIT SW.
CUT-AWAY VIEW OF ELECTRICAL BOX
14
PROGRAM SETTINGS
Logic Control Pushbuttons Open, Close, Stop
Open, Close and Stop buttons are mounted directly on the Logic Control board. [. . . ] Check at the intervals listed in the following chart.
ITEM Drive Chain
PROCEDURE Check for excessive slack. Lubricate Check set screw tightness Check & adjust as required Check condition & tension Check & tighten as required Check for wear & Lubricate
EVERY 3 MONTHS OR 5, 000 CYCLES
EVERY 6 MONTHS OR 10, 000 CYCLES
EVERY 12 MONTHS OR 20, 000 CYCLES
Sprockets Clutch Belt Fasteners
Manual Disconnect Check & Operate Bearings & Shafts
Use SAE 30 Oil (Never use grease or silicone spray). Motor bearings are rated for continuous operation. Inspect and service whenever a malfunction is observed or suspected. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER EH
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER EH will begin.