OWNER'S MANUAL MODEL FDCL
ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR
N
TR
LMPLC
CONTROL WIRED
O
L
2 YEAR WARRANTY
Serial # (located on electrical box cover) Installation Date Wiring Type
NOT FOR RESIDENTIAL USE
41B6
LISTED DOOR OPERATOR
SPECIFICATIONS
DRIVE SYSTEM
GEAR SYSTEM:. . . . . . . . . . . . . . . . . . . . . . . . . . Mixed Spurgear/ Sprocket & Chain CONTINUOUS POWER RATING: 1/2 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 ft-lbs/sec OUTPUT SPEED 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42. 7 rpm OUTPUT TORQUE 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554 in-lbs. 1/2 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1" OUTPUT SPROCKET 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #50-18T MAX. OVERHUNG LOAD: 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375 Lbs. BACK DRIVING FORCE: (torque) 1/2 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 in-lbs. [. . . ] This alarm will override any other alarm condition or input.
8
INSTALL POWER WIRING & CONTROL STATION
Before installing power wiring or control stations be sure to follow all specifications and warnings described below. Failure to do so may result in severe injury to persons and/or damage to operator. Do not install any wiring or attempt to run the operator without consulting the wiring diagram. Install the optional Reversing Edge before proceeding with the Control Station installation.
IMPORTANT SAFETY NOTES
G WARNINGWARNING WARNINGWARNING
INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. DO NOT INSTALL CONTROL STATION DIRECTLY BENEATH THE OPERATOR. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A SAFETY DEVICE MUST BE INSTALLED ON THE DOOR, THE MINIMUM ACCEPTABLE DEVICE WOULD BE SAFETY PHOTO EYES, OR A REVERSING EDGE INSTALLED ON THE BOTTOM OF THE DOOR. THE BEST PROTECTION IS AFFORDED BY THE COMBINATION OF THESE TWO DEVICES. ANY MAINTENANCE TO THE OPERATOR OR IN THE AREA NEAR THE OPERATOR MUST NOT BE PERFORMED UNTIL DISCONNECTING THE ELECTRICAL POWER AND LOCKING-OUT THE POWER VIA, THE MAIN DISCONNECT SWITCH. UPON COMPLETION OF MAINTENANCE THE AREA MUST BE CLEARED AND SECURED, AT THAT TIME THE UNIT MAY BE RETURNED TO SERVICE.
CAUTION CAUTION
WARNING G
WARNINGWARNING
WARNING
WARNING
TO ENSURE DOOR DESCENT IN AN "ALARM" CONDITION, AND AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION.
CAUTION
DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL.
WARNING
WARNING
IMPORTANT CAUTION WARNING
THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY.
WARNING WARNING
CAUTION
WARNING
9
POWER WIRING
POWER WIRING CONNECTIONS 1. Connect power wires to the J1 terminal block located on the Printed Circuit Board (shown below).
CONTROL STATION WIRING
CONTROL WIRING CONNECTIONS 1. Connect control wires to the J2 terminal block located on the Printed Circuit Board (shown below).
2. Be sure to run all power wires through the conduit hole in the electrical box enclosure marked with the label shown below.
2. Be sure to run all control wires through the conduit hole in the electrical box enclosure marked with the label shown below.
GROUND WIRING
1. Connect earth ground to chassis ground screw in the electrical box enclosure marked with the label shown below. Press OPEN push button and observe direction of door travel and then Press the STOP button. If door did not move in the correct direction, check for improper wiring at the control station or between operator and control station. (See page 19)
40-10033B
2. [. . . ] Limit nuts binding on screw threads which Lubricate screw thread. allows them to jump position on retainer. Door `drifts' when motor shuts off. Operator does not shut off at full OPEN or at full CLOSE position. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER FDCL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.