[. . . ] A DUCHOSSOIS ENTERPRISE 845 Larch Avenue Elmhurst, Illinois 60126
OWNER'S MANUAL
MODEL GJ
SOLID STATE
INDUSTRIAL DUTY GEARHEAD JACKSHAFT OPERATOR
The Pr ofession U al Line L
169l COM LISTED ASSEMBERCIAL DOO LED IN R MEXICOOPENER
Lift-Ma ster
CON SWITCH NECT REVE INSTR-USEE INSTARSING EDGE CTIONS LLATION
CAUT ION
INSTAL FOR IN L MOR DOOR SI LOCATE E MUSTGHT OF PERS CONTROL THAN 8' AB USE ONLY OV BE CO ST ON NTROLL OPERAT ATION SO E THE FLOO ED BY ING TH THAT IS R 3 BUTT E CONT WITHI ON ST ROL. Amper e/Phase age Rated Load
Serial # (located on electrical box cover) Installation Date Wiring Type
®
L RO NT G CO IRIN W
NEC CLA SS 2C IRC UIT
32 1
COMMERCIAL DOOR OPERATOR LISTED NOT FOR RESIDENTIAL USE
SPECIFICATIONS
MOTOR
TYPE:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . . . . 1/2, 3/4 & 1 Hp Single or Three phase 1-1/2 & 2 HP Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115/208-230 Single phase 208-230 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate
ELECTRICAL
CONTROL VOLTAGE:. 5V dc AUXILIARY VOLTAGE: 24V dc CONTROL STATION: . . 3 Button OPEN/CLOSE/STOP, NEMA 1 WIRING TYPE: . . . . . . . . . . . . . B2 (Standard) Momentary contact to OPEN/CLOSE/STOP plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. 14) LIMIT ADJUST: . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. Adjustable to 30 feet.
MECHANICAL
DRIVE REDUCTION:. . . . . . . . . . . . . 40:1 Reduction Heavy duty bronze worm gear reducer OUTPUT SHAFT SPEED: . . . . . 43 R. P. M. [. . . ] IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR.
Control Station
OPEN
WARNING
DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND CONNECTED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL.
WARNING
TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR
Push Buttons
CLOSE
Refer to Master Wiring Diagram. Make connection through holes labeled for power and control. Do not run control wires in the same conduit as power wires. CABLE CONNECTION NOTE: Be sure to use the control box opening with the 1-1/16" hole for the POWER cable. All control wires use the 7/8" hole.
7/8" Hole for CONTROL (LOW Voltage) Wires
STOP
WARNING Notice
Sprocket
CONTROL WIRING
Hole for POWER (HIGH Voltage) Wires
Electrical Box
13. Complete electrical connections to the operator and the control station. Fasten the control station to the wall and MOUNT THE WARNING NOTICE BESIDE OR BELOW THE PUSH BUTTONS. Press OPEN push button and observe direction of output shaft rotation. If shaft does not rotate in the correct direction, check for improper wiring at the control station or between operator and control station. If the operator is three phase and control station wiring is correct, exchange any two of the three incoming power leads. If electrical problems persist, call our Toll Free number for assistance (1-800-528-6563). 5
ADJUST LIMITS
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Be sure close limit actuator is engaged as door fully seats at the floor. If other problems persist, call our toll-free number for assistance - 1-800-528-6563.
Press Travel Nut Retainer Down Toward Frame TO DISENGAGE.
Open Limit Nut
Close Limit Nut
Travel Nut Retainer
OPEN
CLOSE
SLS
OLS
Actuator
CLS
Open Limit Switch
Close Limit Switch
6
ADJUST CLUTCH (OPTIONAL)
WARNING
Motor
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER TO OPERATOR BEFORE ADJUSTING SLIP CLUTCH.
Clutch Adjusting Nut
Remove clutch cover and adjust clutch so that it is tight enough to open and close the door but will slip when the door meets an obstruction. Either loosen or tighten the clutch nut with 1/4 turn increments. [. . . ] Release of close button will cause door to reverse (roll-back feature) plus wiring for sensing device to reverse. T* 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close, and stop, with open override and timer to close. Every device that causes door to open, except a reversing device, activates timer to close. Auxiliary controls can be connected to open input to activate the timer to close. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER GJSS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.