User manual LIFT-MASTER GJW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER GJW. We hope that this LIFT-MASTER GJW user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER GJW.


Mode d'emploi LIFT-MASTER GJW
Download
Manual abstract: user guide LIFT-MASTER GJW

Detailed instructions for use are in the User's Guide.

[. . . ] A DUCHOSSOIS ENTERPRISE 845 Larch Avenue Elmhurst, Illinois 60126 OWNER'S MANUAL MODEL GJW NEMA 4 GEARHEAD JACKSHAFT OPERATOR ADDENDUM REFER TO MODEL GJ INSTALLATION INSTRUCTIONS Serial # (located on electrical box cover) Date of Installation Wiring Type ® ® COMMERCIAL DOOR OPERATOR LISTED NOT FOR RESIDENTIAL USE REFER TO PAGE 2 OF GJ OWNER'S MANUAL NEMA UNIT REFER TO PAGE 2 OF GJ OWNER'S MANUAL NEMA UNIT 4-3/4" 32-1/8" Max. (With Clutch) 2-3/4" 5-1/2" Room Required to Open Hinged Electrical Box 16" 14-3/4" Max. 12-1/8" 15-1/2" Max. OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER 1-800-528-6563 HOURS 7:00 TO 3:30 P. M. [. . . ] 4 3 P2-13 1 P3-1 (To Radio) 1 2 3 Radio Control O C Rollback Option Sense to Reverse 6 8 P2-14 Brown 27 P1-10 * NOTE: Remove Jumper If External Interlock is Used. External Interlock* 5 P2-11 Red (When Used) Jumper Orange P1-8 4 SW1 SW1 O Orange P3-2 (To Radio) 1, 500µ IR1 6 A1 P2-6 Orange Red OT3 O L1 Blue Black Red Red OT1 O L3 C TD1 TD2 Orange Yellow Rect. Bridge O C GND IR 8 P1-1 MOTOR Internal Interlock T1 24 Vac Red STOP OLS O Red P2-10 OPEN A2 Time Capsule >1 HP 12 P3-4 (To Radio) + TD1 27 TD2 + SW1 SLS P1-9 3 7 150µ S 8 SW2 S-1 4 6 P2-12 7 Open/Close ADLS TL-2 Brown SW5 TS SW4 TS Grey 3 5 TI-1 C 5 Grey 10 Open/Timer to Close 7 8 (Optional) TI P2-10 SW3 P1-14 P1-13 Blue P2-1 4 6 SW2 S W 3 2 Blue TIMER TO CLOSE ONLY TL-1 8 7 (Optional) TL C 3 IR2 5 Blue A1 P1-7 A2 CLOSE Close Timer 1 11 9 TI-2 Timer Defeat Switch 5 C Blue 1 P1-11 S-2 5 CLS P2-7 P1-12 4 NEMA 4 WITH DYNAMIC BRAKE - 3 PHASE WIRING DIAGRAM (For P. C. Board #14D0379) Red Gray Yellow P1 AUXILARY NC DEVICE LIMIT NO SWITCH C OPEN NC LIMIT SWITCH NO Red Yellow Gray Blue Orange C Brown NC SENSING LIMIT NO SWITCH C 14D383A 12 4 NC Red CLOSE LIMIT NO SWITCH C 1 P2 789 14 Blue Gray Blue Orange Brown Brown Brown Blue Yellow Orange Red White Blue Red A2 96 95 14 T3 T2 T1 72 NO NO NO NO NC Orange Red Blue Gray Yellow LOAD LINE BRAKE LINE XMFR LOAD White Orange Blue 3/4 to 2HP 3 Phase Overload Orange Red White T3 T2 T1 A2 Red 14 T3 T2 T1 NO NO NO NO 71 NC Gray 1. 5 Sec. TIMER Yellow Orange Gray Blue Brown 81 71 53 81 Yel. 71 53 Gray CLOSE 72 NC OPEN 71 NC NO NO NO NO NO NO NO NO Red Red Blue 82 72 54 82 72 54 *1/3 & 1/2 HP Three Phase Blue Orange Black Red Yellow MOTOR Black Black Org. Orange Blue Blue Blue Orange Red Orange Org. Blue Brown Brown A1 13 L3 L2 L1 A2 A1 Red Yellow Red Yellow Orange Blue Blue Gray Yellow Red Brown Red Red > 1 HP Only Red Blue LOAD Red Red LINE Orange TRANSFORMER LINE Red LOAD 14D0379 JU2 JU1 SW1 T3 T2 T1 Interl'k (When Used) Red Red 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P3 Brown Gry. /Wht. Yellow 1 2 4 T12 T11 T10 T9 T8 P2 Remove Jumper to Install Timer Defeat Switch. SW5 T7 TI 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P1 TL S SW2 T4* Red SW4 T6 SW3 T5* 1 2 3 Open/Close Open L1 L2 L3 Close L1 L2 L3 Stop GND · For 3/4 HP Install Interlock Between T4 and T5 RADIO CONTROL Sensing Device Open/Timer Close External Interlock If Required On 1/3 & 1/2 HP 3Ø 5 THREE PHASE SCHEMATIC DIAGRAM - NEMA 4 (For P. C. Board #143D0379) Hot 3Ø L1 White T1 Three Phase Overload Relay (3/4 HP to 2 HP Only) L1 Red Red Red L2 L3 C Red P1-4 P1-1 Red OT1 O Red OT2 C L1 L2 Red Red Orange Red Red OT3 O L1 Blue Black O L3 C TD1 TD2 Orange L2 Red L3 Orange Yellow Rect. Bridge O C Hot 3Ø L2 Red T2 Hot 3Ø L3 Orange T3 GND MOTOR Place Jumper Between 3 & 4 If a Stop Button Is Not Used 4 3 P2-13 1 P3-1 (To Radio) 1 2 3 Radio Control If 3Ø 1/3 or 1/2 HP T'stat with External Interlock P2-11 5 Jumper* Orange Internal Interlock Red (When Used) P1-8 P2-6 >1 HP Only T1 24 Vac Red STOP External Interlock* (3/4 HP to 2 HP Only) * NOTE: Remove Jumper If External Interlock Used or If 3Ø 1/3 or 1/2 HP with T-stat O SW1 P1-10 A1 O Orange P3-2 (To Radio) 1, 500µ 27 A2 C Orange OLS Red P2-10 OPEN SW1 Time Capsule >1 HP 12 P3-4 (To Radio) + TD1 O 27 TD2 C Rollback Option Sense to Reverse 6 8 S-1 4 6 3 7 Open/Close Grey 10 Open/Timer to Close 3 5 TI-1 P1-13 C Blue P2-1 4 6 P2-12 P2-14 Brown SW1 + 150µ SLS P1-9 S 7 8 SW2 ADLS Brown SW5 TS SW4 TS Grey TL-2 5 7 TI P2-10 8 (Optional) SW3 S SW2 W 3 2 P1-14 TIMER TO CLOSE ONLY C TL-1 8 7 (Optional) >1 HP Only O Blue TL Blue Blue A1 P1-7 A2 1 S-2 5 CLS CLOSE Close Timer 1 11 9 TI- 2 Timer Defeat Switch 5 C P2-7 P1-11 P1-12 6 DYNAMIC BRAKE ELECTRICAL BOX WIRING Dynamic Brake Electrical Box Wiring OPEN LIMIT SWITCH C NC NO 16 Orange 17 T I M E R Remove harness wire from OLS-NC remove terminal. Faston 17 and connect here. 1 Yellow 2 Gray 4 White 5 15 Orange 14 Orange T1 T2 T3 NO T1 T2 T3 NO Black P1 12 4 A2 11 Gray 9 Yellow Double Male Faston STANDARD TRANSFORMER The Chamberlain Group, Inc. [. . . ] 575V NEMA Spacer, Limit Switch Seal, Shaft Washer-Sealing 1/2" Connector-Straight 1/2" Conduit, Liquid Tight Connector - 90º 1/2" Motor S. D. 1 HP, 575V, 3Ø Bracket, NEMA GJ Fitting, Liquid Tight Bushing Snap Stand-Off (575V) PCB Mounting Bracket PCB Assy. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER GJW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER GJW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag