Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER HMJ. We hope that this LIFT-MASTER HMJ user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER HMJ.
Detailed instructions for use are in the User's Guide.
[. . . ] FACTORY SET
OWNER'S MANUAL
MODELS:
C2 Wiring
See page 8 for other wiring configurations
MJ
MH
HMJ
INDUSTRIAL DUTY DOOR OPERATOR
2 YEAR WARRANTY
Serial # (located on electrical box cover) Installation Date Wiring Type
NOT FOR RESIDENTIAL USE
41B6
SPECIFICATIONS
MOTOR
TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intermittent duty HORSEPOWER: . . . . . . . . . . . . . . . . 1/2 HP SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 1 Phase 60Hz, 230V 1 Phase 50Hz CURRENT:. . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate
ELECTRICAL
TRANSFORMER:. . . . . . . . . . . . . 24Vac CONTROL STATION: . . . . . . NEMA 1 3-button station. OPEN/CLOSE/STOP WIRING TYPE:. . . . . . . . . . . . . . . . . C2 (Standard) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. See pages 13 and 14 for optional control settings and operating modes. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. [. . . ] After adjustment, release plate and ensure it seats fully in slots of both nuts. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor.
WARNING CAUTION
WARNING
WARNING
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect electric power BEFORE manually moving limit nuts.
If other problems persist, call our toll-free number for assistance - 1-800-528-2806.
OPEN Limit Switch Retaining Plate CLOSE Limit Switch
Aux. Close) Limit Switch 6
WARNING WARNING
POWER WIRING
POWER WIRING CONNECTIONS
1. Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover. Using the 1-1/16" dia conduit access hole as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. Important NOTE: Connect earth ground to the chassis ground screw in the electrical box enclosure. Do not turn power on until you have finished making all power and control wiring connections and have completed the limit switch adjustment procedure.
To reduce the risk of SEVERE INJURY or DEATH: · ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. · Disconnect power at the fuse box BEFORE proceeding. Reversing devices are recommended for ALL installations.
CAUTION
Momentary contact on close (B2 wiring) Move RED wire from terminal block #12 to terminal #2. The operator will require only momentary contact to close the door.
SPECIAL CONTROL WIRING
If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections.
SPECIAL CONTROL WIRING DATA
This Operator has Control Wiring.
SUPPLEMENTAL WIRING DIAGRAM(S)
WIRING
REPLACEMENT WIRING DIAGRAM
Wiring Type
Note: Supplemental Wiring Diagrams are to be used in addition to 1753 or 1754. [. . . ] Inspect and service whenever a malfunction is observed or suspected.
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Installation and service information is available CALL OUR TOLL FREE number: 1-800-528-2806
WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Country Club Tucson, AZ 85706
11
SCHEMATIC DIAGRAM
1754
(OPTIONAL)
(OPTIONAL) W
LIGHT
MAX. 100W C
BIMETAL RELAY
B
BK A W Y
CLOSE-B
C W N. O.
BL
RES. OPEN-A CAPACITOR
MOTOR *
O/L Y R BK
L2
BK
L1
BR
R BK
CLOSE-C OPEN-C 3 STOP 4
MOVE JUMPER WIRE TO TERMINAL #2 FOR MOMENTARY CONTACT ON CLOSE
BRAKE SOLENOID
BL/BK PR1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER HMJ
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER HMJ will begin.