[. . . ] A DUCHOSSOIS ENTERPRISE 845 Larch Avenue Elmhurst, Illinois 60126
OWNER'S MANUAL
SERIES 2000
MODEL HTC NEMA 4
HEAVY DUTY BELT DRIVEN TROLLEY OPERATOR
ADDENDUM REFER TO MODEL HT INSTALLATION INSTRUCTIONS
OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER 1-800-528-6563 HOURS 7:00 TO 3:30 P. M. (MOUNTAIN STANDARD TIME) MONDAY THROUGH SATURDAY
Serial # (located on electrical box cover) Date of Installation Wiring Type
®
®
COMMERCIAL DOOR OPERATOR LISTED
NOT FOR RESIDENTIAL USE
ADJUST LIMITS
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. To increase door travel, spin nut away from actuator. [. . . ] Yellow 1 2 4 Remove Jumper to Install Timer Defeat Switch. P2
14 13 12 11 10 9 8 7 6 5 4 3 2 1 P1 TI TL S SW5 SW4 T6 T5 SW3 T4 SW2 T3 SW1 T2 T1 L1 L2 L3 Open IR 14D0379
LOAD Interlock (When Used) Black Orange Orange Black
T12 T11 T10 1 2 3
T9
T8
T7
OVERLOAD PROTECTOR GND
Open/Close RADIO CONTROL Close Sensing Device Stop Open/Timer Close Hot 115V 1Ø Hot 230V 1Ø Neutral 115V 1Ø Hot 230V 1Ø
3
SINGLE PHASE SCHEMATIC DIAGRAM - NEMA 4 (For P. C. Board #14D0379)
Neutral 115v 1Ø Hot 115v 1Ø L1 White L2 L3 Black Single Phase Overload Protector Orange Red 115 Vac Only P1-4 7 Red L2 L3 C O Red OT2 C L1 L2 Red Red Orange Red Place Jumper Between 3 & 4 If a Stop Button Is Not Used. 4 3 P2-13 1 P3-1 (To Radio) 1 2 3 Radio Control O C Rollback Option Sense to Reverse 6 8 P2-14 Brown 27 P1-10 * NOTE: Remove Jumper If External Interlock is Used. External Interlock* 5 P2-11 Red (When Used) Jumper Orange P1-8 4 SW1 SW1 O Orange P3-2 (To Radio) 2, 200µ IR1 6 A1 P2-6 Orange Red OT3 O L1 Blue Black Red Red OT1 O L3 C TD1 TD2 Orange Yellow Rect. Bridge O C
GND
The Chamberlain Group, Inc. Schematic Diagram Standard Duty Single Phase Schematic - NEMA New PC Board 8/23/91 - 8/27/91 - 9/2/91 - 9/5/91 9/11/91 - 9/14/91 - 9/9/92
IR
8 P1-1
MOTOR
Internal Interlock
T1 24 Vac Red
STOP
OLS
O
Red
P2-10
OPEN
A2 Time Capsule >1 HP 12
P3-4 (To Radio)
+
TD1
27
TD2
+
SW1
SLS
P1-9 3 7
220µ
S
8
SW2
S-1 4 6
P2-12 7 Open/Close
ADLS
TL-2 Brown SW5 TS SW4 TS Grey 3 5 TI-1 C 5
Grey 10 Open/Timer to Close
7 8 (Optional)
TI
P2-10
SW3
P1-14 P1-13
Blue
P2-1 4
6
SW2
S W 3
2 Blue
TIMER TO CLOSE ONLY
TL-1
8 7 (Optional)
TL
C 3 IR2 5 Blue A1 P1-7 A2
CLOSE
Close Timer 1 11 9 TI-2 5
C
Blue
1 P1-11
S-2 5
CLS
P2-7
P1-12
114A1422B
Timer Defeat Switch
4
NEMA 4 WITH DYNAMIC BRAKE - 3 PHASE WIRING DIAGRAM (For P. C. Board #14D0379)
Red Gray Yellow
P1
AUXILARY NC DEVICE LIMIT NO SWITCH C OPEN NC LIMIT SWITCH NO C Red Yellow Gray Blue Orange Brown
Brown
NC SENSING LIMIT NO SWITCH C
14D383A
12
4
NC Red
CLOSE LIMIT NO SWITCH C
1
P2 789
14
Blue
Gray Blue Orange Brown Brown Blue Yellow Orange Red White Blue Red A2 96 95 14 T3 T2 T1
72 NO NO NO NO NC
Orange
Red Gray Yellow
Blue
LOAD
White
Orange
LINE BRAKE LINE XMFR LOAD
Blue 3/4 to 2HP 3 Phase Overload
Orange Red White
T3 T2 T1 A2
Red
14 T3 T2 T1
NO NO NO NO 71 NC Gray
1. 5 Sec. TIMER
Yellow
Orange
Gray Blue Brown
81
71
53
81 Yel.
71
53
Gray
CLOSE 72 NC
OPEN 71 NC NO NO NO NO
NO NO NO NO
Red Red Blue
82
72
54
82
72
54
*1/3 & 1/2 HP Three Phase
Blue Orange Black Red Yellow
MOTOR
Black
Black
Org. Orange Blue Blue Blue Orange Red Orange Org. Blue Brown Brown A1
13 L3 L2 L1 A2 A1 Red Yellow Red Yellow
Orange Blue
Blue Gray Yellow Red
Brown Red
Red
> 1 HP Only Red
Blue
LOAD Red Red LINE Orange TRANSFORMER LINE Red LOAD 14D0379 JU2 JU1 SW1 T3 T2 T1 Interl'k (When Used)
Red Red
14 13 12 11 10 9 8 7 6 5 4 3 2 1 P3 Brown Gry. /Wht. Yellow 1 2 4 T12 T11 T10 T9 T8 P2 Remove Jumper to Install Timer Defeat Switch. SW5 T7 TI
14 13 12 11 10 9 8 7 6 5 4 3 2 1 P1 TL S SW2 T4*
Red
SW4 T6
SW3 T5*
1
2
3 Open/Close
Open
L1 L2 L3
Close L1 L2 L3 Stop GND · For 3/4 HP Install Interlock Between T4 and T5
RADIO CONTROL
Sensing Device Open/Timer Close
External Interlock If Required On 1/3 & 1/2 HP 3Ø
5
THREE PHASE SCHEMATIC DIAGRAM - NEMA 4 (For P. C. Board #14D0379)
Hot 3Ø L1 White T1 Three Phase Overload Relay (3/4 HP to 2 HP Only) L1 Red Red Red L2
Hot 3Ø L2 Red T2
Hot 3Ø L3 Orange T3
GND
L2 Red L3
L3 Orange
The Chamberlain Group, Inc. Schematic Diagram Standard Duty Three Phase - NEMA (New PC Board) Standard Duty CDO #1 (Red) 8/9/91 - 9/3/91 - 9/5/91 - 9/11/91 - 9/13/91 11/12/91 - 8/28/92
Yellow TD1 TD2 Orange Rect. Bridge O C
L3 C
C Red P1-4 P1-1 Red OT1 O Red
O
OT2 C L1
OT3 O L1 Blue Black Red Orange
MOTOR
L2 Red
Red
Red
Place Jumper Between 3 & 4 If a Stop Button Is Not Used 4 3 P2-13 1 P3-1 (To Radio) 1 2 3 Radio Control
If 3Ø 1/3 or 1/2 HP T'stat with External Interlock P2-11 5 Jumper* Orange
Internal Interlock Red (When Used) P1-8 P2-6 >1 HP Only
T1 24 Vac Red
STOP
External Interlock* (3/4 HP to 2 HP Only) * NOTE: Remove Jumper If External Interlock Used or If 3Ø 1/3 or 1/2 HP with T-stat
O
SW1 P1-10 A1 O Orange P3-2 (To Radio) 2, 200µ 27 A2 C
Orange
OLS
Red P2-10
OPEN
SW1
Time Capsule >1 HP
12
P3-4 (To Radio)
+
TD1
O 27
TD2
C Rollback Option Sense to Reverse 6 8 S-1 4 6 3 7 Open/Close Grey 10 Open/Timer to Close 3 5 TI-1 P1-13 C Blue P2-1 4 6 P2-12 P2-14 Brown SW1
+
220µ
SLS
P1-9
S
7 8
SW2
ADLS
Brown SW5 TS
SW4 TS Grey
TL-2 5
7
TI
P2-10 8
(Optional)
SW3 S SW2 W 3
2
P1-14
TIMER TO CLOSE ONLY C
TL-1
8 7 (Optional) >1 HP Only S-2 O 5 1 Blue P1-11
TL
Blue
Blue
A1 P1-7
A2
CLS
CLOSE
Close Timer 1 11 9 TI- 2 5
C
P2-7
P1-12
114A1423C
Timer Defeat Switch
6
DYNAMIC BRAKE ELECTRICAL BOX WIRING
Electrical Box Wiring
OPEN LIMIT SWITCH C NC NO
16 Orange 17
T I M E R
Remove harness wire from OLS-NC remove terminal. [. . . ] 1 HP 575V, 3 Ø Pulley Shaft NEMA Nut Plate HT Bracket Assy. HT Bracket NEMA HJ Stand-Off (575V) PCB Mounting Bracket PCB Assy. (Dynamic Brake)
13 16 17 9 5 3 15 18
9 10
180B0159-3 11 180B0159-6 180B0159-4 180B0159-1 180B0159-4 180B0159-1 12 001D4113 001D4438 13 14 184A0115 168A0002 216A0176 023A0080 172A0036 023A0079 123D0126 123D0127 123D0128 19 123D0129 123D0130 123D0131
8
6 20 12 14 2
15 16 17 18
1
19
7
21
MODEL HTC ONLY
20
123D0132 123D0133 123D0154 181B0117 184A0117 001C4112 001C4111 012D0490 184A0136 012B0529 001C4312
23 24 (MODEL HJC ONLY) 22 21
21* 22* 23* 24* 25 26 27 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER HTC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER HTC will begin.