Detailed instructions for use are in the User's Guide.
[. . . ] FACTORY SET
C2 Wiring
See page 8 for other wiring configurations
OWNER'S MANUAL
MODELS:
J
3
H
3
HJ
INDUSTRIAL DUTY DOOR OPERATOR
2 YEAR WARRANTY
Serial # (located on electrical box cover) Installation Date Wiring Type
NOT FOR RESIDENTIAL USE
41B6
LISTED DOOR OPERATOR
SPECIFICATIONS
MOTOR
TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . 1/3, 1/2, 3/4 & 1 Hp Single or Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115, 220, 230 Single phase 208, 230, 460, 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate
ELECTRICAL
TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. See pages 13 and 14 for optional control settings and operating modes. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. [. . . ] ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL.
POWER WIRING
1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover. Using the 1-1/16" dia conduit access hole as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. CAUTION: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY.
WARNING
TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH.
ON THREE PHASE MACHINES ONLY!Incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE button is pressed and vice-versa). A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door.
WARNING
INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR.
MOUNT WARNING NOTICE
IMPORTANT: Mount WARNING NOTICE beside or below the push button station.
Control Station
OPEN
Push Buttons
WARNING
CLOSE
TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR
STOP
WARNING Notice
8
CONTROL WIRING (con't)
Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. However, for complete door control from a transmitter, a commercial three-channel radio set (with connections for OPEN/CLOSE/STOP) is recommended.
WARNING
DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. IN ADDITION, IF A SINGLE CHANNEL CONTROL IS USED, THE USER WILL NOT BE ABLE TO STOP THE DOOR FROM THE TRANSMITTER.
Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. Any control with a normally (N. O. ) isolated output contact may be connected in parallel with the OPEN button. More than one device may be connected in this manner. [. . . ] Refer to page 11 for all repair part ordering information. K72-12563 CLUTCH SHAFT REPLACEMENT KIT
ITEM PART # DESCRIPTION QTY 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 7 4 1 5 1 1 1 4 ITEM
INDIVIDUAL PARTS
PART # DESCRIPTION QTY
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25
10-10166 10-10882 11-10892 12-10715 12-10882 12-10883 15-10885 15-48B14LXX 16-5L304 17-10165 18-10168 18-11379 19-48047M 39-10167 75-10884 80-10022 80-10883 80-206-10 80-206-11 84-SH-76 85-FW-75 86-RP08-200 86-RP10-200 86-RP10-208 87-E-100
Clutch Plate Chain Guide Clutch Shaft Bushing Flange, 1" Bushing . 753 I. D. x 5/8" NY Liner Bearing Sprocket, 48B32/48B14 Sprocket, 48B14 x 1" Bore V Belt, 5L x 30. 4" 7" Pulley Spring, Comp. - Hoist #48 Chain 47P W/ML Clutch Pad Chain Wheel Assy Spacer . 80 I. D. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER J
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.