TABLE OF CONTENTS TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Tools Needed for Installation . . 3 Additional Items Needed for Installation . . 3 Operator Dimensions and Specifications . . 4
WARNING
Mechanical
WARNING
OPERATOR WARNINGS CAUTION
Safety Installation Information . [. . . ] Press remote button, the LED will flash, alarm output will activate twice. Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum). NOTE: For highest level of security, we recommend the Security® line of products.
COMPATIBLE REMOTES - 315MHz
PassportTM Remote CPT13 CPT23 CPT33 Security® Keyless Entry 376LM Security® Remotes 370LM 371LM 372LM 373LM 374LM
R1
LEARN XMITTER
2
J19 K6
P2 P1
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
L1
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
BRN GRN WHT YEL
D1Ø K2
DIAGNOSTIC
LiftM
ast er
BLU RED
Z12 K1 Q9
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WIRE STOP BUTTON (OPTIONAL)
A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm).
P2 P1 R223
J19 K6
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
CLOSE EDGE
R2Ø7 Z2Ø R227
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92 Z9
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
CONTROL INPUTS OPEN
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
SINGLE BUTTON RESET STOP
COM OVLD OVLD
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
COM
LOOP INPUTS
Q22
D22
SHADOW INTERRUPT CHGR OVLD
F6 F2
COM
POWER
D15 R4 C2 R196
COM
24 VAC/ SOLAR INPUT J4
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
17
OPTIONAL CONTROL DEVICES
SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence. Reset Control Input (N/O) The control box has a factory installed internal reset button. These terminals are intended for use with a single reset button that is installed within line of sight of the gate. This input functions to reset the alarms. Open (N/O) - Opens only or reverses a closing gate. Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input.
PR
ESE NC RE E LAY 2
Sa
EXIT LOOP
5 62
ras
ota
X
62
SE NS
FRE EQQ
5X
IN DE MA A US
OPEN COMMON
AND/OR
CONTROL INPUTS OPEN SINGLE BUTTON RESET STOP
SINGLE BUTTON COMMON
COM
COM
POWER
AND/OR
COMMON RESET
P2 P1 R223
J19 K6
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
CLOSE EDGE
R2Ø7 Z2Ø R227
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92 Z9
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
COM OVLD OVLD
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
LOOP INPUTS SHADOW INTERRUPT CHGR OVLD
Q22
D22
D15 R4 C2 R196 F6
COM
24 VAC/ SOLAR INPUT J4
F2
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
18
LOOP INPUTS (P11) Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Interrupt Loop Input Terminal and Common This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close.
LOOP INPUTS SHADOW INTERRUPT CHGR OVLD F1 20A 32V
SHADOW LOOP INTERRUPT LOOP COMMON LOOP
COM
FUSE OPEN
BATT 2
BATT 1
PR
E SE NC RE E LAY 2
Sa
ras
62
5X
ota
6 2 NS 5X
FRRE EQQ
MA IN DE A US
SE
PHOTO/EDGE INPUTS (P6-7-8 and 9) Terminal P6 Close Safety Edge This input will reverse a closing gate. It will disable the Timer-to-Close if that feature has been enabled. Activating this input while the gate is opening will have no effect. Order part number LA400-BOX to enclose safety electronics.
CLOSE EDGE
Terminal P8 Open Safety Edge/Photo Eye If an Open Edge device or a Retro-Reflective Photo Eye has been connected to Terminal P8, then this input will reverse an opening gate for 2 seconds then stop. Activating this input with an Open Edge device or a Retro-Reflective Photo Eye connected to Terminal P8 while the gate is closing will have no effect. If a Chamberlain Pulsing Photo Eye has been connected to Terminal P8, then this input will pause an opening gate until the obstruction has been removed. Upon removing the obstruction, the gate will continue to open. Activating this input with a Chamberlain Pulsing Photo Eye connected to Terminal P8 while the gate is closing will have no effect.
OPEN EDGE PHOTO
BRO
BRO E BLU
BL U
WN
E
WN
Terminal P7 Open Safety Photo Eye This input will pause an opening gate until the obstruction has been removed. [. . . ] Replace the control board.
DIAGNOSTIC CODES
# OF BLINKS
1 2 3 4 5 6 7 8 9 10
MEANING
No Stop Switch Connected Gate 1 Arm Disengaged Gate 2 Arm Disengaged Both Gate Arms Disengaged RPM Reversal Force Reversal Processor Reset ROM Check Failed RAM Check Failed EEPROM Check Failed
28
REPAIR PARTS
Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. CONTROL BOX LA400-CONT
ITEM 1 2 3 4 5 6 7 8 Not Shown PART # K001A6039 K75-15480 K75-30764 K23-19380 K74-19499 K74-30762 K74-30763 K76-19446 K74-30941 DESCRIPTION Control Board Control Box & Cover with Gasket Control Board Bracket Reset Switch Antenna Battery Transformer Alarm ATC Fuse Kit Includes 20 Amp (1), 15 Amp (2) QTY 1 1 1 1 1 2 1 1
8
2
7
3
4 1
6
5
29
REPAIR PARTS
ACTUATOR ARM KITS
ITEM 1 2 3 4 Not Shown PART # 41ASWG-442SA 41ASWG-438SA 41ASWG-0014SA 41ASWG-454 41ASWG-0119 DESCRIPTION Release Lever Motor with Limit Switch Harness Rear Connector Cable 24V with Connector Release Key QTY 1 1 1 1 1
2
1
3
4
30
O P E R AT O R N O T E S
31
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LA400
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LA400 will begin.