User manual LIFT-MASTER LA400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER LA400. We hope that this LIFT-MASTER LA400 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER LA400.


Mode d'emploi LIFT-MASTER LA400
Download
Manual abstract: user guide LIFT-MASTER LA400

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL MODEL LA400 MEDIUM DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # Primary Arm Serial # Secondary Arm Serial # Box Installation Date TABLE OF CONTENTS TABLE OF CONTENTS OPERATOR SPECIFICATIONS Tools Needed for Installation . . 3 Additional Items Needed for Installation . . 3 Operator Dimensions and Specifications . . 4 WARNING Mechanical WARNING OPERATOR WARNINGS CAUTION Safety Installation Information . [. . . ] Press remote button, the LED will flash, alarm output will activate twice. Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum). NOTE: For highest level of security, we recommend the Security® line of products. COMPATIBLE REMOTES - 315MHz PassportTM Remote CPT13 CPT23 CPT33 Security® Keyless Entry 376LM Security® Remotes 370LM 371LM 372LM 373LM 374LM R1 LEARN XMITTER 2 J19 K6 P2 P1 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE NO C MAGLOCK K5 NO C NC Z1 10A 32V L1 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 BRN GRN WHT YEL D1Ø K2 DIAGNOSTIC LiftM ast er BLU RED Z12 K1 Q9 GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WIRE STOP BUTTON (OPTIONAL) A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm). P2 P1 R223 J19 K6 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE CLOSE EDGE R2Ø7 Z2Ø R227 NO C MAGLOCK K5 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 Z9 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO CONTROL INPUTS OPEN GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING SINGLE BUTTON RESET STOP COM OVLD OVLD 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 COM LOOP INPUTS Q22 D22 SHADOW INTERRUPT CHGR OVLD F6 F2 COM POWER D15 R4 C2 R196 COM 24 VAC/ SOLAR INPUT J4 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 17 OPTIONAL CONTROL DEVICES SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence. Reset Control Input (N/O) The control box has a factory installed internal reset button. These terminals are intended for use with a single reset button that is installed within line of sight of the gate. This input functions to reset the alarms. Open (N/O) - Opens only or reverses a closing gate. Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input. PR ESE NC RE E LAY 2 Sa EXIT LOOP 5 62 ras ota X 62 SE NS FRE EQQ 5X IN DE MA A US OPEN COMMON AND/OR CONTROL INPUTS OPEN SINGLE BUTTON RESET STOP SINGLE BUTTON COMMON COM COM POWER AND/OR COMMON RESET P2 P1 R223 J19 K6 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE CLOSE EDGE R2Ø7 Z2Ø R227 NO C MAGLOCK K5 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 Z9 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING COM OVLD OVLD 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 LOOP INPUTS SHADOW INTERRUPT CHGR OVLD Q22 D22 D15 R4 C2 R196 F6 COM 24 VAC/ SOLAR INPUT J4 F2 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 18 LOOP INPUTS (P11) Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Interrupt Loop Input Terminal and Common This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close. LOOP INPUTS SHADOW INTERRUPT CHGR OVLD F1 20A 32V SHADOW LOOP INTERRUPT LOOP COMMON LOOP COM FUSE OPEN BATT 2 BATT 1 PR E SE NC RE E LAY 2 Sa ras 62 5X ota 6 2 NS 5X FRRE EQQ MA IN DE A US SE PHOTO/EDGE INPUTS (P6-7-8 and 9) Terminal P6 ­ Close Safety Edge This input will reverse a closing gate. It will disable the Timer-to-Close if that feature has been enabled. Activating this input while the gate is opening will have no effect. Order part number LA400-BOX to enclose safety electronics. CLOSE EDGE Terminal P8 ­ Open Safety Edge/Photo Eye If an Open Edge device or a Retro-Reflective Photo Eye has been connected to Terminal P8, then this input will reverse an opening gate for 2 seconds then stop. Activating this input with an Open Edge device or a Retro-Reflective Photo Eye connected to Terminal P8 while the gate is closing will have no effect. If a Chamberlain Pulsing Photo Eye has been connected to Terminal P8, then this input will pause an opening gate until the obstruction has been removed. Upon removing the obstruction, the gate will continue to open. Activating this input with a Chamberlain Pulsing Photo Eye connected to Terminal P8 while the gate is closing will have no effect. OPEN EDGE PHOTO BRO BRO E BLU BL U WN E WN Terminal P7 ­ Open Safety Photo Eye This input will pause an opening gate until the obstruction has been removed. [. . . ] Replace the control board. DIAGNOSTIC CODES # OF BLINKS 1 2 3 4 5 6 7 8 9 10 MEANING No Stop Switch Connected Gate 1 Arm Disengaged Gate 2 Arm Disengaged Both Gate Arms Disengaged RPM Reversal Force Reversal Processor Reset ROM Check Failed RAM Check Failed EEPROM Check Failed 28 REPAIR PARTS Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. CONTROL BOX LA400-CONT ITEM 1 2 3 4 5 6 7 8 Not Shown PART # K001A6039 K75-15480 K75-30764 K23-19380 K74-19499 K74-30762 K74-30763 K76-19446 K74-30941 DESCRIPTION Control Board Control Box & Cover with Gasket Control Board Bracket Reset Switch Antenna Battery Transformer Alarm ATC Fuse Kit Includes 20 Amp (1), 15 Amp (2) QTY 1 1 1 1 1 2 1 1 8 2 7 3 4 1 6 5 29 REPAIR PARTS ACTUATOR ARM KITS ITEM 1 2 3 4 Not Shown PART # 41ASWG-442SA 41ASWG-438SA 41ASWG-0014SA 41ASWG-454 41ASWG-0119 DESCRIPTION Release Lever Motor with Limit Switch Harness Rear Connector Cable 24V with Connector Release Key QTY 1 1 1 1 1 2 1 3 4 30 O P E R AT O R N O T E S 31 WARRANTY POLICY AND SERVICE LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LA400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LA400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag