User manual LIFT-MASTER SAMSKIT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SAMSKIT. We hope that this LIFT-MASTER SAMSKIT user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER SAMSKIT.
Manual abstract: user guide LIFT-MASTER SAMSKIT
Detailed instructions for use are in the User's Guide.
[. . . ] SEQUENCED ACCESS MANAGEMENT SYSTEM (SAMS)
WARNING
FIGURE 1
Model SAMS KIT
WARNING
To avoid SERIOUS personal INJURY or DEATH from electrocution, DISCONNECT electrical power to operator BEFORE proceeding.
TRAFFIC
Ho
Gate 1
op Lo pen ld O
STREET
The Sequenced Access Management System or SAMS allows more control when managing vehicular entrances to areas such as apartment complexes, businesses, gated communities and parking lots. The basic concept of the system is that there are two gate operator systems installed in tandem, a fast moving gate such as a barrier gate operator and a slower moving more secure or ornamental gate system balances the demands of speed during high traffic periods with security during low traffic periods. [. . . ] As long as the second operator is in the full open position, any additional open pulse sent will in turn energize the MEGA ARM's K1 relay to send another open signal to the second operator as well as cause the arm to raise again if it has closed via a car crossing the MEGA ARM's close loop.
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
REVERSE SENSOR
Common
ALARM SENSOR
OFF
OPEN LEFT
ON
OPEN RIGHT
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
®
OmniControl Surge Suppressor
GBA
123456
7 8 9 10 11 12 13
P/N Q410 Patent Pending
+ Radio Receiver
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
Class 2 Supply
24 Volts DC
Elite Operator Control Board shown for reference (Omni Board)
11 8
9 10
Connect Auxiliary Open Limit Switch to the operator which is to be sequenced with the barrier of the second gate operator.
CLOSE
STOP
Operator to be sequenced
1 3 1
OPEN
Normally Open
POWER OVERLOAD
1
3
3
SE
MADE IN USA
Common
C NO NC
Normally Closed
1
INSTALLATION
SAMS KIT - PARTS LIST DESCRIPTION K1 Relay Auxiliary Limit Switch QUANTITY 1 1
SEQUENCED ACCESS MANAGEMENT OF TWO MEGA ARM BARRIERS
(REQUIRES THE OPTIONAL SAMS KIT) NOTE: (5. 20 or greater) can be used when you have two entry gates that you want sequence with each other. This is when you can only have ONE gate raised at a time (bottle neck or gates at a cross street). In this case, which ever one raises first will get first priority, while if the other gets an open signal, it will be HELD IN MEMORY, then raise once the first gate closes. This will work if either gate has a telephone entry unit or access device (AVI, prox, etc. ). of each gate to the SHADOW LOOP J5 #8 input and common of the other (Figure 2). (Leave S1-6 and 8 OFF to allow relay to stay latched. ) The auxiliary open limit switch will not be used in this installation.
NOTE: Most units will require that this EXTRA limit switch be added to their open limit switch assembly. Install the K1 relay onto the control board of the Mega Arm operator. Auxiliary switch mounting: Remove (2) pan head screws securing OPEN switch and discard. Mount auxiliary OPEN switch on top of existing OPEN switch with (2) pan head screws provided (Figures 3 & 4). Run two wires from the second operator's isolated common and normally closed contacts of auxiliary open limit switch (provided with kit) to the MEGA ARM J5 #8 and one of the commons J5 #9-12. Run two wires from the MEGA ARM's K1 relay (common and normally open) to the second operator's common and open input. J5 #8 was the unused SHADOW LOOP input on the MEGA ARM. [. . . ] In this mode, if the arm senses an impact, the K1 relay will stay energized holding open (or teeth down) the second operator until the arm times out and closes.
FIGURE 3 Model CSW200
New Screws
New Switch Existing Switch
FIGURE 4 Model SL3000
New Screws
New Switch Existing Switch
01-60219
© 2005, The Chamberlain Group, Inc. All Rights Reserved
Printed in Mexico [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SAMSKIT Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SAMSKIT will begin.