If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SL-3000-UL. We hope that this LIFT-MASTER SL-3000-UL user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER SL-3000-UL.
Manual abstract: user guide LIFT-MASTER SL-3000-UL
Detailed instructions for use are in the User's Guide.
[. . . ] G) All warning signs and placards must be installed where visible in the area of the gate. H) For a gate operator utilizing a non-contact sensor such as a photo beam: 1) See instructions on the placement of non-contact sensor for each Type of application, 2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate still moving, and 3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. I) For a gate operator utilizing a contact sensor such as an edge sensor: 1) One or more contact sensors shall be located at the leading edge, trailing edge and postmounted both inside and outside of a vehicular horizontal slide gate. 2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. [. . . ] EXIT LOOP
13
OPEN LEFT OPEN RIGHT
STRIKE RADIO GATE OPEN RECEIVER LOCKED SAFETY CENTER RESET MOTOR LOOP LOOP
RADIO
HOW
TO
CONNECT
POWER
Minimum: 15-Amp Breaker Switch Per Operator Required
Do Not Use This Outlet Unless You Are An Authorized Service Technician Suggestion:
Seal all open holes of electronic box with sealant when finished wiring.
White Wires (Neutral)
Use U. L. Listed Conduit for Supplying Power to the Unit Black Wires (120 VAC) Green Wires (Ground)
WIRE GUAGE REQUIREMENT FOR 120 VAC POWER SUPPLY: 1/2 HP AND DUAL MOTOR ONLY 16 Gauge 150 Feet 14 Gauge 250 Feet 12 Gauge 400 Feet 10 Gauge 650 Feet 8 Gauge 1000 Feet 4 Gauge 2200 Feet
Caution: ELITE ACCESS SYSTEMS, INC. is not responsible for conflicts between the information listed in the above chart and the requirements of your local building codes. The information is for suggested use only. Check your local codes before installation.
Gate Operator MUST be properly grounded.
ADJUSTING
GATE
TRAVELING
DISTANCE
Nut
Push Plate
Plate
Each notch indicates an estimated 1 inch of gate travel
Before Adjusting, Do the Following: 1. Turn the Power OFF!Roll the nut to the direction desired.
3. If you need more adjusting, repeat the process.
Adjusted by Qualified Service Personnel
CENTER
SAFETY
EXIT
Maximum Sensitivity
1 3
DC-BACKUP
W4 GB
MS LINK
A SYSTEM ON
SENSORS
TIMER 60 3
POWER OVERLOAD
1
3
OFF
1 3 1 3 OPEN LEFT
ON
OPEN RIGHT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Minimum Sensitivity
DO NOT Touch Alarm Sensor
The level of sensitivity has to do with the weight of the gate and the condition of installation. Too sensitive = if the gate stops or reverses by itself. OFF OPEN LEFT ON OPEN RIGHT
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
W4 G BA
MS LINK
Use Shielded Twisted Wires W4 to Connect Gate Operators Together
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
GBA
MS LINK
TIMER
60
1
3
3
1. Turn timers onBOTH Omni boards to the "OFF" position
OFF
OPEN LEFT
ON
OPEN RIGHT
PARTIAL
MASTER/INDIVIDUAL
CONTROL
IN ORDER FOR THE FOLLOWING OPERATION TO OCCUR, FOLLOW THE INSTRUCTIONS. EXAMPLE: There is a double gate, the entry gate is to be opened with a radio transmitter and the exit gate with a free exit loop. Only one safety loop system is to open both gates, and a fire department switch should open both gates at the same time. Connect the radio receiver to entry gate only. Connect the exit loop to exit gate only. Connect the safety loop to both entry and exit gates. Connect the fire department switch to both entry and exit gates.
SOLENOID/MAGLOCK
J3
CONNECTION
Wire Harness
1 3 Normally Closed Common
J3
2
CENTER SAFETY EXIT
8 10
7 9
Normally Open
DC-BACKUP W4 GB A MS LINK SYSTEM ON SENSORS TIMER 60 3 POWER OVERLOAD
1 3
OFF
1 3 1 3
ON OPEN RIGHT
Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit.
OPEN LEFT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Solenoid Lock
Solenoid Lock
J3
2 1 3 8 10 7 9 #3 Normally Closed
Ground Plug-In Transformer
#7 Common
Wire Nut
Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness)
Power Ground
Magnetic Lock
J3
2 1 3 8 10 7 9 #8 Normally Open
Power Ground Magnetic Lock
Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) #7 Common
Ground
Plug-In Transformer
Wire Nut
QCC socket with QCC access ID inserted QCC "Mode of Operation" switch
QCC
AB
DC-BACKUP
OPEN
STOP
CLOSE
MAGLOCK
ALARM
ARMED
M/S LINK
QCC
W4 GBA
OPEN A B MAGLOCKALARMARMED M/S LINK MS LINK STOP CLOSE
SYSTEM ON
SENSORS
TIMER 60 3
POWER OVERLOAD
1
3
OFF
1 3 1 3
ON
OPEN RIGHT
OPEN LEFT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
QCC is designed for slide gate operators only!
1 & 2 Open Command 3 & 4 Stop Command 5 & 6 Close Command 7 Common 8 Normally Closed 9 Normally Open Maglock or Solenoid
Omni Option Board Elite Part # O-OMNI EXB
10 & 11 Burglar Alarm Output 12 & 13 Burglar Alarm Input 14 Ground 15 B 16 A Master/Slave RS485
QCC
(QUICK
CLOSE
QCC Access Socket
CURCUIT)
Mode of Operation Switch
QCC Access ID (Top Positive)
QCC Access ID Elite Part # O-QCC OMNI Omni Option Board Elite Part # O-OMNI EXB the QCC can operate in two different modes. The mode of operation will depend on the switch on the Omni option board. Mode A (switch off) If the gate is closing while a car is driving over the safety loop detector, the QCC will stop the gate for a second then open the gate while the car is over the safety loop detector. As soon as the car leaves the safety loop, the QCC will resume closing the gate. Mode B (switch on) If the gate is closing, and a vehicle drives over the safety loop, the QCC will stop the gate. After the vehicle leaves the safety loop, the QCC will close the gate.
SE
MAGLOCK
7 Common 8 Normally Closed AL 9 Normally Open
Solenoid Lock
CENTER SAFETY EXIT
7
8
9
DC-BACKUP QCC A B MAGLOCKALARMARMED M/S LINK
Ground
W4 GB A
MS LINK OPENSTOPCLOSE
SYSTEM ON
SENSORS
TIMER 60
1
Plug-In Transformer
3
3
POWER OVERLOAD
OFF
1 3 1 3
ON
OPEN RIGHT
OPEN LEFT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
Wire Nut
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Omni Option Board Elite Part # O-OMNI EXB
Power Ground
SE
MAGLOCK
7 Common 8 Normally Closed AL 9 Normally Open
CENTER
SAFETY
EXIT
7
8
9
Magnetic Lock
DC-BACKUP QCC A B MAGLOCKALARMARMED M/S LINK
Ground
W4 GB A
MS LINK OPENSTOPCLOSE
SYSTEM ON
SENSORS
TIMER 60
1
3
3
POWER OVERLOAD
Plug-In Transformer
OFF
1 3 1 3
ON
OPEN RIGHT
OPEN LEFT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
Wire Nut
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Omni Option Board Elite Part # O-OMNI EXB
Power Ground
MASTER/SLAVE
WITH
OPTIONAL
BOARD
ED
M/S LINK
CENTER
SAFETY
EXIT
G
B
A
DC-BACKUP QCC A B MAGLOCKALARM ARMED M/S LINK SENSORS
W4 GB A
MS LINK OPENSTOPCLOSE
SYSTEM ON
TIMER
60
1
3
3
POWER OVERLOAD
OFF
1 3 1 3
ON
OPEN RIGHT
OPEN LEFT
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Use this socket (M/S LINK) if the Omni option board is being used, and Master/Slave option is needed.
HOUSE
ALARM/PROXIMITY
SWITCH
QCC A OPEN STOP CLOSE B MAGLOCKALARM ARMED M/SLINK
Omni Option Board Elite Part # O-OMNI EXB
10
11
12
13
CENTER
SAFETY
EXIT
DC-BACKUP QCC W4 AB GB A O P E N S T O P C L O S E MAGLOCKALARMARMED /S LINK M MS LINK SYSTEM ON SENSORS TIMER 60 3 POWER OVERLOAD
13 13 13
FIRE DEPT. STRIKE OPEN OFF OPEN LEFT ON OPEN RIGHT
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Use Low Voltage Wire 20 AWG
OmniControl Board 12VDC House Alarm System Dry Contact
2"
Max.
House Alarm
Proximity Switch Elite Part # A PRS
CENTER
SAFETY
EXIT
CAUTION:
Use different frequencies for every single loop detector. [. . . ] 2. The wire loop has been disrupted 3. The loop detector needs to work in a different frequency 4. The loop detector is too sensitive 1. Reset the loop detector (If you use Elite Plug-in Loop detectors, change the setting for sensitivity and come back to your original setting). 2. Verify and correct connections 3. Set a different working frequency 4. Decrease the sensitivity of the loop detector
ANY "LOOP LED" ON And NO VEHICLE ON THE SENSING AREA
SL-3000
Limit Switch Assembly
Q010
PARTS
Power Back-Up
SL Q164
*Q029
Q031
*Q032 O-DC
SL DM Q065
Q123 Q051 *Q101 Q209 Q143
Q033
Q023
O-DC-SL O-DC-SL DM
Q254
Q177
Q024
Q030
Electronic Box Assembly
Q421
Q028 Q237
Q039
Q020 Q021
Q025
Q027 Q420 Q112
Q014 Q018 Q016 Q015 A H-110 #41 A H-113
Q402 1/2 HP Q403 1 HP
Q408 Q404 Q401 Q400
*Q013
A H-111 #40 A H-125
Q006
A ELD
O-OMNI EXB
Q005 *Q003 *Q004
Q009
O-QCC OMNI
Note: *Sold Individually, 2 Shown. For part names, refer to parts list
SL-3000
Idler Sprocket Assembly Q013
PARTS
LIST
AH-110 - Gate Chain No. 41 (10 ft) A H-111 - Gate Chain No. 40 (10 ft) A H-113 - Master Link, Nickel Plated A H-125 - Master Link Limit Switch Assembly Q003 - Chain Bolt Q010 - Limited Switch Box Cover Q004 - Chain Bracket Q023 - Limit Switch Box Q005 - SL-3000 Chassis Q031 - Limit Switch / Shaft Q006 - PC Board Nuts (1 Set) Q024 Q032 - Limit Switch Adjustment Nuts Q009 - Electronic Access Panel Q014 - Drive Sprocket Q051 - Limit Switch / Shaft Bearing Q015 - Gear Reducer Q101 - Limit Switch Bearing Holder Q016 - Limited Switch Drive Sprocket Q018 - 1/2 HP Electric Motor Power Back-Up Unit Q020 - Drive Belt Q065 - Drive Belt (DM) Q021 - Gear Pulley Q123 - Back-Up Motor DC 12V Q025 - Motor Pulley Q143 - Chassis DC Back-Up O-DC-SL Q027 - Motor Capacitor O-DC-SL DM Q164 - Drive Belt Q028 - Manual Crank Q177 - Wire Harness DC-1000 Q029 - Limit Switch Q209 - Pulley DC-1000 1/2 ID Q030 - Limit Switch / Chain Q033 - Limit Switch Sprocket Q039 - Drive Belt, DM and 1 HP Electronic Box Assembly Q112 - Wire Harness-B Terminal Block Q402 1/2 HP Q403 1 HP Q237 - Crank Input Q254 - Cover HD Polyethylene Flexible Assembly for 1/2 Horse Motor Q400 - OMNI Main PCB Q420 Wire Harness and Conduit Q401 - OMNI 1 Horsepower Board # Q404 - OMNI Alarm Flexible Assembly for Dual Motor Q408 - Electronic Power Strip Q421 Wire Harness and Conduit A ELD - Loop Detector # Muliple Parts "Q" Numbers O-OMNI EXB - OMNI Option Board# #OmniControl Board Accessories O-QCC OMNI - QCC Access ID#
MAINTENANCE
1. Make sure the reversing sensor is functioning properly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL-3000-UL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.