User manual LIFT-MASTER SL3000UL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SL3000UL. We hope that this LIFT-MASTER SL3000UL user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER SL3000UL.


Mode d'emploi LIFT-MASTER SL3000UL
Download
Manual abstract: user guide LIFT-MASTER SL3000UL

Detailed instructions for use are in the User's Guide.

[. . . ] ® TM Instruction Manual SL3000ULTM SERIES H I G H T R A F F I C C O M M E R C I A L G AT E O P E R AT O R UL325 UL991 compliant compliant LISTED installation instructions and manual book for architects, general contractors and dealers © 2005 the chamberlain group, inc. ­ all rights reserved S L 3 0 0 0 U LTM Overview Limit Switch Box Pg. 20 Motor Capacitor Motor Interlock Assembly Drive Belt EMERGENCY RELEASE Pg. 28 Optional Factory Installed DC2000 Battery Back-Up Motor Models DC and DCH Only Radio Receiver Pg. 27 Gear Reducer Cover Built-In Reset Button Pg. 24 EMERGENCY RELEASE Crank Tool Pg. 28 Crank Tool Housing Pg. 28 Radio Receiver Antenna Chassis Limit Switch Chain Sprocket Operator ON OFF Switch Control Box OFF ON Limit Switch Chain Drive Sprocket Optional Factory Installed Heater Models H and DCH Only Pg. 33 Idler Wheels Optional Factory Installed DC2000 Battery Back-Up Controller Models DC and DCH Only Pg. 30 ® W4 Optional Plug-In Loop Detectors Pg. 39 OmniControlTM Board Surge Suppressor Terminal Pg. 19 UL Alarm Pg. 25 DC2000 Harness Pg. 30 SL Power Wires Pg. 18 N IO AC V UT20eutrald 1 CAck e NGroun la B hit n W ree G TM LISTED 1 TABLE OF CONTENTS Safety Instructions Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Horizontal Slide Gate Systems UL Listings Warnings and Precautions 4 4 5 5 6-9 10 Installation Recommended Setup and Operator Specifications Gate Post Warning Mounting Required Warning Signs Types of Installation Connecting the Chain Concrete Pad and Gate Attachment Gate and Operator Mounting Distance Optional Post Mounting Plate How to Connect Power (110 V) Surge Suppressor Terminal Input Connections (Wiring Optional Equipment) Choosing Gate Movement Direction (Open Left or Right) Adjusting Gate Traveling Distance (Limit Switches) Two-Way Adjustable Reversing Sensor Adjustable Timer Master / Second Operators with Timer On Master / Second Operators with Timer Off Built-In Reset Button Remove Control Board Audio Alarm Solenoid/Maglock J3 Plug Connection Radio Receiver Programming 11 12 13 14 15 15 16 17 18 19 20 20 21 21 22 23 24 25 25 26 27 Table Of Contents EMERGENCY RELEASE Optional Emergency Release Please DO NOT Touch me!. . Unless you are an Authorized Service Technician! © 2005 The Chamberlain Group, Inc. All Rights Reserved. 28 29 For Technical Support: 1-800-528-2806 2 TABLE OF CONTENTS Optional Factory Installed Equipment Optional Factory Installed DC2000 Back-Up Connection. Models DC and DCH Only Wiring Optional Devices to DC2000 Wiring Optional Safety Devices to DC2000 Optional Factory Installed Heater. [. . . ] Unscrew 3 nuts and remove board. AUDIO ALARM When one of the following events happens Twice Consecutively, the Alarm will Sound for 5 minutes! Press the Built-In Reset Button to Shut Off Alarm and Reset Operator!(See previous page) 1 The gate is too heavy. Audio Alarm 2 Debris is on the gate's track such as mud, rocks, dirt, etc. 3 The gate is hitting a wall or vehicle. 4 The gate has one or more broken wheels. 5 A moving vehicle has hit the gate and the wheel is off the track. 25 SOLENOID/MAGLOCK J3 CONNECTION 2 4 CENTER SAFETY EXIT 1 3 5 7 9 J3 Normally Closed Common 6 8 10 SENSOR ALARM Solenoid / Maglock J3 Connection Normally Open Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit. Relay Contact Rating 0. 5 A - 125 Vac 1 A - 24 VDC DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Solenoid Lock 2 4 6 8 10 1 3 5 7 9 #7 Common Solenoid Lock J3 #3 Normally Closed Ground Plug-In Transformer Wire Nut Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness) Power Ground Magnetic Lock Magnetic Lock 2 4 6 8 10 1 3 5 7 9 J3 Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) #7 Common Ground Plug-In Transformer Wire Nut Power Ground #8 Normally Open 26 RADIO RECEIVER PROGRAMMING Note: Hand Held Remote NOT Included with Gate Operator. Radio Receiver Programming Up to 31 Security Plus, Passport remotes or unlimited dip switch remotes can be used. Programming Radio Receiver: Press and Release the "Learn Button". Within that time, press a desired button on your hand held remote for 3 seconds to program the radio receiver. Repeat this process for every hand held remote to be used with the gate operator. Erase ALL Remote Control Codes: Press and Hold the "Learn Button" until LED turns off (6 seconds). All codes are now erased. Optional Hand Held Remotes Part # 971LM Part # CPT1 Part # 972LM Part # CPT2 Mini 3 Button Part # 970LM l ona Optiducts Pro Part # 973LM Part # CPT3 Mini 3 Button Part # CPTK3 Part # 974LM Part # CPT4 Mini 3 Button with HID Prox. Sensor Part # CPTK3PH 27 EMERGENCY RELEASE Emergency Release Turn the power OFF! Crank Tool Push In Push the crank tool in hole. Turn the crank to open the gate. Note: You may use a cordless power drill (6"/sec) for quicker opening in non-emergency situations. Allen wrench drill bit size is 5/16" 28 OPTIONAL EMERGENCY RELEASE Fire Release Box Part # CP17 Turn the power OFF to the gate operator and unlock the fire box. Optional Emergency Release Pull firmly on the "T" Handle to release the chain. l on a Opti uct Prod The chain is held in place by a spring loaded pin. For More Details, ask your Local Dealer 29 OPTIONAL 1 2 FACTORY INSTALLED DC2000 Plug in the 12 pin plug into the DC2000 control unit. Make sure the "System ON" and "Charge OK" LEDs are lit. If the "Battery Low" led comes on, the battery needs to charge before it can be used. Make sure "Gate Direction" setting on DC2000 is set the same as the gate operator's setting. Optional Factory Installed DC2000 l ona Opti duct Pro All devices wired to the DC2000 MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControlTM board. CLASS I, II, III, IV Important: Socket ess 00 Harn DC20 123 456 7 DO NOT wire 110 Vac power to the DC2000 Motor Safety Wires DO NOT Remove System Setup "Manual" setting: The DC2000 will respond to the input devices wired to the J 20 socket. This mode can also be used as an emergency override. If 110 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket. "Auto" setting: The DC2000 opens the gate automatically upon 110 Vac power failure and stays open. When 110 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual command) 110 Vac Power Failure 110 Vac Power On, OmniControlTM Board Malfunction Turn the 110 Vac power off then push and Hold to operate gate Turn the 110 Vac power off then gate opens automatically 110 Vac Power On, Emergency Override Push and Hold to override the OmniControlTM board Push and Hold to override the OmniControlTM board Manual Mode Auto Mode Push and Hold to operate gate Gate automatically opens 30 WIRING OPTIONAL DC2000 DEVICES Important: All devices wired to the DC2000 MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControlTM board. If the DC2000 is automatically opening the gate due to a power failure, any manual command such as "One-Button", "Three Push Button", "Key Switch", "Photo Beam" or "Edge Sensor" will cancel the automatic mode of the DC2000. After such cancellation, the DC2000 will continue to operate in manual mode until 110 Vac power is restored. Manual One-Button 123 456 7 DO Not Remove the 2 Factory Installed Wires in the J 20 Socket Wiring Optional DC2000 Devices Part # AEXITP l ona Optiducts Pro Push and "Hold" to Open Push again and "Hold" to Close Key Switch 123 4 567 Part # A1KX EMERGENCY OVERRIDE If 110 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with ANY of these devices shown. Turn and "Hold" to Open Turn again and "Hold" to Close Radio Receivers 1 56 234 7 12 V 12 VDC Radio Receiver Jumper P2: Back-Up Operation Only to Momentary (M) Jumper P3: to 12 Volt 3 2 1 Normal Gate Operation 56 44 4 Part # 412HM Three-Button 123 456 7 to OmniControl board 24 VDC radio receiver to be used by OmniControlTM Board ONLY Button Three: Optional Accessories ® 3 N. O. N. O. Com Com 4 2 4 Button Two: Back-Up Operation (DC2000) Button One: Normal Gate Operation (OmniControlTM Board) 1 Com 4 3 Push Button Part # 02-103 Push and "Hold" a Button to operate Push and "Hold" DC2000 Transmitter Button to Open Push again and "Hold" DC2000 Transmitter Button to Close 31 WIRING OPTIONAL DC2000 SAFETY DEVICES Edge Sensor UL Listed 3 Sided Sensor CENTER SAFETY EXIT Wiring Optional DC2000 Safety Devices DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR SENSOR ALARM MADE IN USA Part #s G65MGO20 SENSOR ALARM G65MGR20 G65MGS20 DC-BACKUP POWER OVERLOAD nal ptio cts O du Pro OmniControlTM Board Sensor Connection CLASS I, II, III, IV Important: DO NOT remove any existing attached wires from the Sensor/Alarm connector. Photo Beam Sensor 12 VDC Part # AOMRON12V DO Not Remove the 2 Factory Installed Wires in the J 20 Socket 6 Power +12 VDC 4 123 456 7 Power Ground Contact your local dealer for more information. USE ONLY 12 VDC FAILSAFE PHOTO BEAM SENSORS FOR THIS SAFETY OPTION Failsafe Photo Beam: If a photo beam is not working, loses power or photo beam is blocked, then the photo beam will stop all gate operation. 32 OPTIONAL FACTORY INSTALLED HEATER Connect the black, white and ground wire from the heater to the 110 Vac power supply as shown. When the heater switch is left in the "ON" position, the heater will turn on and off automatically when needed. Switch should remain in the "ON" position. DON'T TOUCH Heater may be HOT when the switch is "ON"! Optional Factory Installed Heater OFF ON nal ptio uct Od Pro W4 SL P B la Wh ck 12 Gre ite N 0 VA en eutr C Gro al und ower W ires Green Wires (Ground) CA UT ION Power Supply (110 Vac) Black Wires (110 Vac) White Wires (Neutral) 33 OPTIONAL OMNI OPTION BOARD DESCRIPTION CENTER SAFETY EXIT QCC socket with QCC access ID inserted QCC "Mode of Operation" switch QCC Optional Omni Option Board Description DC-BACKUP OPEN SENSOR ALARM AB CLOSE MAGLOCK ALARM ARMED M / S LIN K STOP QCC W4 GBA OPEN A B MAGLOCK ALARM ARMED M/S LINK MS LINK STOP CLOSE SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED N. O. Gnd CLOSE 1 2 STOP 3 N. C. 4 Gnd 5 N. O. 6 Gnd 7 Com 8 N. C. 9 10 11 12 13 14 15 16 N. O. Gnd Gnd B EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR QCC is designed for slide gate operators only! 1 3 5 & & & Omni Option Board Part # OOMNIEXB 2 ­ Open Command 4 ­ Stop Command 6 ­ Close Command 7 ­ Common 8 ­ Normally Closed 9 ­ Normally Open l ona Opti duct Pro Solenoid Maglock 10 & 11 ­ Burglar Alarm Output 12 & 13 ­ Burglar Alarm Input 14 ­ Ground 15 ­ B 16 ­ A Master/ Second or RS485 OPTIONAL QCC (QUICK /S CLOSE LI NK CIRCUIT) Optional QCC Quick Close Circuit QCC Access Socket QCC Access ID (Top Positive) AR C B A CL ST OP OS E MA GL AL OC K AR M ME D QC M A + + A Omni Option Board Part # OOMNIEXB QCC Access ID Part # OQCCOMNI The QCC can operate in two different modes. [. . . ] Make sure the gate track is clear of dirt, rocks or other substances. Make sure the wheels are operating smoothly on the track. If you hear an alarm, refer to pages 24 and 25. Remove interlock assembly with 3 screws to replace belt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL3000UL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SL3000UL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag