User manual LIFT-MASTER SL3000UL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SL3000UL. We hope that this LIFT-MASTER SL3000UL user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER SL3000UL.
Manual abstract: user guide LIFT-MASTER SL3000UL
Detailed instructions for use are in the User's Guide.
[. . . ] ®
TM
Instruction
Manual
SL3000ULTM SERIES
H I G H T R A F F I C C O M M E R C I A L G AT E O P E R AT O R
UL325 UL991
compliant compliant
LISTED
installation instructions and manual book for architects, general contractors and dealers
© 2005 the chamberlain group, inc. all rights reserved
S L 3 0 0 0 U LTM
Overview
Limit Switch Box Pg. 20 Motor Capacitor Motor Interlock Assembly Drive Belt EMERGENCY RELEASE Pg. 28 Optional Factory Installed DC2000 Battery Back-Up Motor Models DC and DCH Only Radio Receiver Pg. 27 Gear Reducer
Cover
Built-In Reset Button Pg. 24 EMERGENCY RELEASE Crank Tool Pg. 28 Crank Tool Housing Pg. 28 Radio Receiver Antenna
Chassis
Limit Switch Chain Sprocket
Operator ON OFF Switch Control Box
OFF
ON
Limit Switch Chain Drive Sprocket Optional Factory Installed Heater Models H and DCH Only Pg. 33 Idler Wheels Optional Factory Installed DC2000 Battery Back-Up Controller Models DC and DCH Only Pg. 30
®
W4
Optional Plug-In Loop Detectors Pg. 39 OmniControlTM Board Surge Suppressor Terminal Pg. 19 UL Alarm Pg. 25 DC2000 Harness Pg. 30 SL Power Wires Pg. 18
N IO AC V UT20eutrald 1 CAck e NGroun la
B hit n W ree G
TM
LISTED
1
TABLE
OF
CONTENTS
Safety Instructions
Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Horizontal Slide Gate Systems UL Listings Warnings and Precautions 4 4 5 5 6-9 10
Installation
Recommended Setup and Operator Specifications Gate Post Warning Mounting Required Warning Signs Types of Installation Connecting the Chain Concrete Pad and Gate Attachment Gate and Operator Mounting Distance Optional Post Mounting Plate How to Connect Power (110 V) Surge Suppressor Terminal Input Connections (Wiring Optional Equipment) Choosing Gate Movement Direction (Open Left or Right) Adjusting Gate Traveling Distance (Limit Switches) Two-Way Adjustable Reversing Sensor Adjustable Timer Master / Second Operators with Timer On Master / Second Operators with Timer Off Built-In Reset Button Remove Control Board Audio Alarm Solenoid/Maglock J3 Plug Connection Radio Receiver Programming 11 12 13 14 15 15 16 17 18 19 20 20 21 21 22 23 24 25 25 26 27
Table Of Contents
EMERGENCY RELEASE
Optional Emergency Release
Please DO NOT Touch me!. . Unless you are an Authorized Service Technician!
© 2005 The Chamberlain Group, Inc.
All Rights Reserved.
28
29
For Technical Support: 1-800-528-2806
2
TABLE
OF
CONTENTS
Optional Factory Installed Equipment
Optional Factory Installed DC2000 Back-Up Connection. Models DC and DCH Only Wiring Optional Devices to DC2000 Wiring Optional Safety Devices to DC2000 Optional Factory Installed Heater. [. . . ] Unscrew 3 nuts and remove board.
AUDIO
ALARM
When one of the following events happens Twice Consecutively, the Alarm will Sound for 5 minutes!
Press the Built-In Reset Button to Shut Off Alarm and Reset Operator!(See previous page)
1 The gate is too heavy.
Audio Alarm
2 Debris is on the gate's track such as mud, rocks, dirt, etc.
3 The gate is hitting a wall or vehicle.
4 The gate has one or more broken wheels.
5 A moving vehicle has hit the gate and the wheel is off the track.
25
SOLENOID/MAGLOCK
J3
CONNECTION
2 4
CENTER SAFETY EXIT
1 3 5 7 9
J3
Normally Closed Common
6 8 10
SENSOR ALARM
Solenoid / Maglock J3 Connection
Normally Open Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit.
Relay Contact Rating
0. 5 A - 125 Vac 1 A - 24 VDC
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Solenoid Lock
2 4 6 8 10 1 3 5 7 9
#7 Common
Solenoid Lock
J3
#3 Normally Closed
Ground Plug-In Transformer
Wire Nut
Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness)
Power Ground
Magnetic Lock
Magnetic Lock
2 4 6 8 10
1 3 5 7 9
J3
Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) #7 Common
Ground
Plug-In Transformer
Wire Nut Power Ground
#8 Normally Open
26
RADIO
RECEIVER
PROGRAMMING
Note: Hand Held Remote NOT Included with Gate Operator.
Radio Receiver Programming
Up to 31 Security Plus, Passport remotes or unlimited dip switch remotes can be used.
Programming Radio Receiver:
Press and Release the "Learn Button". Within that time, press a desired button on your hand held remote for 3 seconds to program the radio receiver. Repeat this process for every hand held remote to be used with the gate operator.
Erase ALL Remote Control Codes:
Press and Hold the "Learn Button" until LED turns off (6 seconds). All codes are now erased.
Optional Hand Held Remotes
Part # 971LM
Part # CPT1
Part # 972LM
Part # CPT2
Mini 3 Button Part # 970LM
l ona Optiducts Pro
Part # 973LM Part # CPT3
Mini 3 Button Part # CPTK3
Part # 974LM
Part # CPT4
Mini 3 Button with HID Prox. Sensor Part # CPTK3PH
27
EMERGENCY
RELEASE
Emergency Release
Turn the power OFF!
Crank Tool
Push
In
Push the crank tool in hole. Turn the crank to open the gate.
Note: You may use a cordless power drill (6"/sec) for quicker opening in non-emergency situations.
Allen wrench drill bit size is 5/16"
28
OPTIONAL
EMERGENCY
RELEASE
Fire Release Box
Part # CP17 Turn the power OFF to the gate operator and unlock the fire box.
Optional Emergency Release
Pull firmly on the "T" Handle to release the chain.
l on a Opti uct Prod
The chain is held in place by a spring loaded pin.
For More Details, ask your Local Dealer 29
OPTIONAL
1 2
FACTORY
INSTALLED
DC2000
Plug in the 12 pin plug into the DC2000 control unit. Make sure the "System ON" and "Charge OK" LEDs are lit. If the "Battery Low" led comes on, the battery needs to charge before it can be used. Make sure "Gate Direction" setting on DC2000 is set the same as the gate operator's setting.
Optional Factory Installed DC2000
l ona Opti duct Pro
All devices wired to the DC2000 MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControlTM board.
CLASS I, II,
III, IV
Important:
Socket
ess 00 Harn DC20
123
456
7
DO NOT wire 110 Vac power to the DC2000 Motor Safety Wires DO NOT Remove
System Setup
"Manual" setting: The DC2000 will respond to the input devices wired to the J 20 socket. This mode can also be used as an emergency override. If 110 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket. "Auto" setting: The DC2000 opens the gate automatically upon 110 Vac power failure and stays open. When 110 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual command)
110 Vac Power Failure
110 Vac Power On, OmniControlTM Board Malfunction
Turn the 110 Vac power off then push and Hold to operate gate Turn the 110 Vac power off then gate opens automatically
110 Vac Power On, Emergency Override
Push and Hold to override the OmniControlTM board Push and Hold to override the OmniControlTM board
Manual Mode Auto Mode
Push and Hold to operate gate Gate automatically opens
30
WIRING
OPTIONAL
DC2000
DEVICES
Important: All devices wired to the DC2000 MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControlTM board.
If the DC2000 is automatically opening the gate due to a power failure, any manual command such as "One-Button", "Three Push Button", "Key Switch", "Photo Beam" or "Edge Sensor" will cancel the automatic mode of the DC2000. After such cancellation, the DC2000 will continue to operate in manual mode until 110 Vac power is restored.
Manual One-Button
123
456 7
DO Not Remove the 2 Factory Installed Wires in the J 20 Socket
Wiring Optional DC2000 Devices
Part # AEXITP
l ona Optiducts Pro
Push and "Hold" to Open Push again and "Hold" to Close
Key Switch
123
4 567
Part # A1KX
EMERGENCY OVERRIDE
If 110 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with ANY of these devices shown. Turn and "Hold" to Open Turn again and "Hold" to Close
Radio Receivers
1
56 234 7
12 V
12 VDC Radio Receiver Jumper P2: Back-Up Operation Only to Momentary (M) Jumper P3: to 12 Volt
3 2 1
Normal Gate Operation
56 44 4
Part # 412HM
Three-Button
123
456 7
to OmniControl board 24 VDC radio receiver to be used by OmniControlTM Board ONLY Button Three: Optional Accessories
®
3
N. O. N. O.
Com Com
4
2
4
Button Two: Back-Up Operation (DC2000)
Button One: Normal Gate Operation (OmniControlTM Board)
1
Com 4
3 Push Button Part # 02-103
Push and "Hold" a Button to operate
Push and "Hold" DC2000 Transmitter Button to Open Push again and "Hold" DC2000 Transmitter Button to Close
31
WIRING OPTIONAL DC2000 SAFETY DEVICES
Edge Sensor
UL Listed 3 Sided Sensor
CENTER SAFETY EXIT
Wiring Optional DC2000 Safety Devices
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
SENSOR ALARM
MADE IN USA
Part #s G65MGO20
SENSOR ALARM
G65MGR20 G65MGS20
DC-BACKUP
POWER OVERLOAD
nal ptio cts O du Pro
OmniControlTM Board Sensor Connection
CLASS I, II,
III, IV
Important: DO NOT remove any existing attached wires from the Sensor/Alarm connector.
Photo Beam Sensor 12 VDC
Part # AOMRON12V
DO Not Remove the 2 Factory Installed Wires in the J 20 Socket
6
Power +12 VDC
4
123
456
7
Power Ground
Contact your local dealer for more information.
USE ONLY 12 VDC FAILSAFE PHOTO BEAM SENSORS FOR THIS SAFETY OPTION Failsafe Photo Beam: If a photo beam is not working, loses power or photo beam is blocked, then the photo beam will stop all gate operation.
32
OPTIONAL
FACTORY
INSTALLED
HEATER
Connect the black, white and ground wire from the heater to the 110 Vac power supply as shown. When the heater switch is left in the "ON" position, the heater will turn on and off automatically when needed.
Switch should remain in the "ON" position.
DON'T
TOUCH
Heater may be HOT when the switch is "ON"!
Optional Factory Installed Heater
OFF
ON
nal ptio uct Od Pro
W4
SL P
B la Wh ck 12 Gre ite N 0 VA en eutr C Gro al und
ower W ires
Green Wires (Ground)
CA UT
ION
Power Supply (110 Vac)
Black Wires (110 Vac)
White Wires (Neutral)
33
OPTIONAL OMNI OPTION BOARD DESCRIPTION
CENTER SAFETY EXIT
QCC socket with QCC access ID inserted QCC "Mode of Operation" switch
QCC
Optional Omni Option Board Description
DC-BACKUP
OPEN
SENSOR ALARM
AB
CLOSE MAGLOCK ALARM ARMED M / S LIN K
STOP
QCC
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M/S LINK
MS LINK STOP CLOSE
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
N. O.
Gnd CLOSE
1
2
STOP
3
N. C.
4
Gnd
5
N. O.
6
Gnd
7
Com
8
N. C.
9 10 11 12 13 14 15 16
N. O. Gnd Gnd B
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
QCC is designed for slide gate operators only!
1 3 5
& & &
Omni Option Board Part # OOMNIEXB
2 Open Command 4 Stop Command 6 Close Command 7 Common 8 Normally Closed 9 Normally Open
l ona Opti duct Pro
Solenoid Maglock
10 & 11 Burglar Alarm Output 12 & 13 Burglar Alarm Input 14 Ground 15 B 16 A Master/ Second or RS485
OPTIONAL
QCC
(QUICK
/S
CLOSE
LI NK
CIRCUIT)
Optional QCC Quick Close Circuit
QCC Access Socket QCC Access ID (Top Positive)
AR C B A CL ST OP OS E MA GL AL OC K AR M ME D QC M
A
+
+
A
Omni Option Board Part # OOMNIEXB QCC Access ID Part # OQCCOMNI
The QCC can operate in two different modes. [. . . ] Make sure the gate track is clear of dirt, rocks or other substances. Make sure the wheels are operating smoothly on the track. If you hear an alarm, refer to pages 24 and 25. Remove interlock assembly with 3 screws to replace belt. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL3000UL Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SL3000UL will begin.