[. . . ] GL
CO NT RO LL ER
BO AR D
HEAVY DUTY SLIDE GATE OPERATOR
MODEL SL585
MODEL SL595
2 YEAR WARRANTY
Serial # ________________________ (located on electrical box cover) Installation Date __________________
HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR
MODELS SL585 AND SL595 ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Carton Inventory . . 2 Operator Dimensions and Horsepower Chart . . 4
IMPORTANT NOTES
· BEFORE attempting to install, operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
OPERATOR WARNINGS
Safety Installation Information . [. . . ] Installation device instructions: Always follow the instructions provided by the manufacturer when installing and adjusting any control device. If these instructions are contrary to the advice given here, call for assistance.
CLOS
E
ST OP
Interrupt (Safety) Loop Input (N. O)
Shadow Loop Input (N. O. )
RF QE
RF QE
Obstruction While Opening Edge/Photo Eye Input (N. O. )
Radio (Single Button) Input (N. O. )
Obstruction While Closing Edge/Photo Eye Input (N. O. )
17
ACCESSORY WIRING
All inputs are normally open and momentary, except the stop (N. C. ). The following instructions are based upon UL325, and include recommendations for significant increase in safety. We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions shipped with optional control devices for mounting, wiring, programming and adjustment. The LiftMaster Radio Receiver comes pre-wired to the operator · Remove the brass antenna from the accessary box and screw it onto the "F"-connector provided on the side of the gate operator. NOTE: The radio receiver is wired in the factory for single button control to open and close the gate.
RADIO RCVR.
Receiver
Operator Terminal
4 3
Connector Antenna
R4 R3 R2 R1
Relay Control 24Vac Power
2 1
Accessory Tray
1 234567
REMOTELY MOUNTED STOP/RESET CONTROL WIRING · This control will function as a Stop/Reset command and is to be wired within line of sight of the gate. · Wire Stop/Reset control station to terminals 3 and 5 on the control box on the operator. Make sure that all Stop/Reset controls are wired in series. Terminals 6 & 5 (Com) - Soft Open These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads, 7-Day Timer. NOTE: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on).
Control Conduit Control Conduit
1
2
3
Stop/Reset Button
Stop/Reset Button
1
234
5
6
7
8 9 10 11 12 13 14
123 56 789 0#
Soft Open
18
R1
R2
R3 R4
ACCESSORY WIRING (CONTINUED)
Terminals 7 & 5 (Com) - Hard Open Override Control Input These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to open. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 4 & 5 (Com) - Close Override Control Input These terminals are intended for use only with the close control of a 3-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to close. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 8 & 5 (Com) - Interrupt (Safety) Loop Input These terminals are intended for use with a loop detector. This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close. [. . . ] VOLTAGE +24V ac/dc +24V ac/dc
36
NOTES
37
WARRANTY
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL585
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SL585 will begin.