User manual LIFT-MASTER SW2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SW2000. We hope that this LIFT-MASTER SW2000 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER SW2000.


Mode d'emploi LIFT-MASTER SW2000
Download
Manual abstract: user guide LIFT-MASTER SW2000

Detailed instructions for use are in the User's Guide.

[. . . ] ESTATE SERIES X3 MODEL SW 2000-X3 INSTALLATION MANUAL HEAVY DUTY, HIGH CYCLE SWING GATE OPERATOR MODEL SW 2000-X3 IS FOR VEHICULAR PASSAGE GATES ONLY, NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE 3 YEAR WARRANTY Serial # _____________________ (located on electrical box) Installation Date ______________ TABLE OF CONTENTS SAFETY SUMMARY ___________________________________________________________________1 BASIC INSTALLATION HINTS AND RULES ______________________________________________2 PART 1 SITE PREPARATION __________________________________________________________3 A. LOCATION AND LAYOUT ________________________________________________________________ 3 B. PAD AND MOUNT _______________________________________________________________________ 4 C. POWER WIRING_________________________________________________________________________ 5 D. [. . . ] There is no squeak or vibration in the gate when it is moving . There is no belt slippage when the gate moves or stops. There is no slack in the closed gate due to loose chain or parts. Both gates open and close at the same time (Bi-Parting gates only). Gate Sensitivity and Obstruction Alarm (Primary Obstruction Sensing per UL 325 Requirements) 1. Left/Right Obstruction sensitivity: Apply a bump to the opening and closing gate and verify that the gate stops or reverses. Start-Up Sensitivity: Apply a bump to the gate as it starts moving and verify that the gate responds to the bump within a second. Obstruction Alarm: Cause two obstruction faults before the gate reaches its open or closed limit and verify that the Obstruction Alarm sounds. Activate the CYCLE input (entry system), RADIO input (radio transmitter), and EXIT Loop input (driving over the exit loop) and verify that they fully open the gate. If Reclose Timer is enabled, it will close the gate. Activate the FIRE input (fire department switch) and verify that the gate fully opens and then closes after 5 seconds. If Reclose Timer is enabled, it will close the gate. 18 of 42 Doc 01-20099 Rev F 6. Alternate Action If Alternate Action has been selected so that CYCLE or RADIO commands both open and close the gate: Activate the CYCLE command, wait until the gate is fully open, then activate the CYCLE command again. The gate should close, verifying Alternate Action operation. Note: If you select Alternate Action, you can't enable ATG and RT in procedures 6 and 8. Reclose Timer If Reclose Timer has been enabled in programming step 8, verify Reclose Timer as follows: 1. Activate any entry command (except Manual OPEN) to open the gate. Start timing when the gate reaches fully open and verify that the Reclose Timer recloses the gate after the desired interval. NOTE: Reclose Timer is not functional when the Manual OPEN command is used. Interrupt Loop and Anti-Tailgating (ATG) When Exiting Gate Type is SWING (Enter 1 in Programming Step 01): Inside Interrupt Loop: When a vehicle drives on the Interrupt Loop a moving gate will stop. When the vehicle drives off the Interrupt loop, the gate will open. Outside Interrupt Loop: When a vehicle drives on the Interrupt Loop a closing gate will open (an opening gate will not be affected). [. . . ] However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SW2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SW2000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag