Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SW420. We hope that this LIFT-MASTER SW420 user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER SW420.
Detailed instructions for use are in the User's Guide.
[. . . ] GL
CO NT RO LL ER
BO AR D
MODEL SW420
LIGHT DUTY SWING GATE OPERATOR
2 YEAR WARRANTY
Serial # ________________________ (located on electrical box cover) Installation Date __________________
MODEL SW420 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Carton Inventory . . 4-5
IMPORTANT NOTE
· BEFORE attempting to install, operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. · These instructions are intended to highlight certain safety related issues. These instructions are not intended to be comprehensive. [. . . ] The following instructions are based upon UL325, and include recommendations for significant increase in safety. We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions shipped with optional control devices for mounting, wiring, programming and adjustment.
Field Wiring Terminal Blocks
R1 R2 R3 R4 3 5 5 8 9 10 11 12
J1 Terminal Block
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SW420 Operator
24Vac Accessory PowerCan be found at terminals R1 & R2 located on radio terminal block.
R1 R2 R3 R4
GL Board
24 Vac
J1 Terminals 1 & 5 - Residential Radio (single button) Input These terminals are intended for use with a radio receiver in a residential application or as a single button control. This allows the user to open the gate by activating the transmitter when the gate is closed or between limits. This input also gives the user the ability to close the gate by activating the transmitter when the gate is on the open limit. J1 Terminals 2 & 5 - Shadow Loop Input These terminals are intended for use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active.
RESIDENTIAL RADIO (SINGLE BUTTON) INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SHADOW LOOP INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
RF QE
J1 Terminals 6 & 5 - Soft Open These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads, 7-Day Timer. Note: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on).
123 56 789 0#
SOFT OPEN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
RF QE
Field Wiring Terminals 8 & 5 - Interrupt (Safety) Loop Input These terminals are intended for use with a loop detector. This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close.
INTERRUPT (SAFETY) LOOP INPUT
5 8 9 10 11 12
RF QE
19
OPTIONAL CONTROL DEVICES
Field Wiring Terminals 9 & 5 - Obstruction Open (Edge/ Photo Eye Input) Edge Input: See Programming Section This input will reverse an opening gate to the close limit. Activating this input when the gate is closing will have no effect. Note: If upon reversal a second seperate obstruction is detected (gate edge or R. P. M. Photo Eye Input: See Programming Section This input will pause an opening gate. Once the input (photo eye) is cleared, the gate continues to open. Activating this input when the gate is closing will have no effect. Field Wiring Terminals 10 & 5 - Obstruction Close (Edge/ Photo Eye Input) Edge Input: See Programming Section This input will reverse a closing gate to the open limit. When reaching the open limit the timer to close, if enabled, will be disabled until another command is given. Activating this input when the gate is closing will have no effect. Note: If upon reversal a second seperate obstruction is detected (gate edge or R. P. M. Photo Eye Input: See Programming Section This input will reverse a closing gate to the open limit. This input will not affect the timer to close. [. . . ] CLOSE 24 VAC-COMMON (W) DC-GND (RD) LOCK 1 LOCK 1
3
OPTION
FI ELD WIRING
R1 R2 R3 R4 3 5 5 8 9 10 11 12
24 VAC
RADIO SIGNAL
STOP
INTERRUPT LOOP
R1
ALARM 1 ALARM 1
ENTRAPMENT OPEN ENTRAPMENT CLOSE
SEE NOTE 4 J4 DUAL GATE 1 2
TO PRIMARY/SECONDARY UNIT
NOTES:
1) TRANSFORMER PRIMARY VOLTAGE SAME AS OPERATOR LINE VOLTAGE 24V SECONDARY 15VA. 2) TERMINAL DESIGNATIONS SHOWN FOR 115V ONLY. 4) (B+) AND (B-) ARE 100db SAFETY ALARMS. 5) CONNECTED INTERNALLY ON GL PC BOARD
APPLICATIONS:
CONTROL WIRING TYPE - GL
FIELD WIRING & ADJUSTMENTS
MODEL TYPES: HORSEPOWER: VOLTAGE/PHASE:
DRAWING NUMBER:
SW420 1/3
115V & 230V - 1 PHASE ONLY
REV:
845 Larch Avenue, Elmhurst, IL 60125
G1977
C
31
NOTES
32
NOTES
33
NOTES
34
WARRANTY POLICY
Seller warrants that the goods are free from defect in materials and/or workmanship for a period of two years from the date of shipment from the F. O. B. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SW420
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SW420 will begin.