User manual LISTAESCAN ARLINK 8000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LISTAESCAN ARLINK 8000. We hope that this LISTAESCAN ARLINK 8000 user guide will be useful to you.

Lastmanuals help download the user guide LISTAESCAN ARLINK 8000.


Mode d'emploi LISTAESCAN ARLINK 8000
Download
Manual abstract: user guide LISTAESCAN ARLINK 8000

Detailed instructions for use are in the User's Guide.

[. . . ] 4 In-Line Station. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Square Corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Drawer, Tote Box & CPU Holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Place the worksurface in the desired location and fasten the support brackets using the six 1/4"-20 x 3/4" machine screws provided and tighten once all are in place. Rear Corner Leg Support This worksurface is mounted using one pair of worksurface support brackets. Adjust the height of the leg relative to the worksurface by unfastening the screw at the bottom of the leg assembly and sliding the inner tube up or down as required. Fine adjustments can be done with the leveling glide. Now slide the rear leg to the back corner of the worksurface approximately 2" from either side and fasten to the worksurface using the wood screws provided. Round Corner or Straight Back Corner Worksurface These worksurfaces are mounted between two 900 adjacent modules. They require one pair of worksurface support brackets. Place the worksurface in the desired location and fasten the support brackets using the four 1/4"-20 x 3/4" machine screws provided and tighten once all are in place. Drawer, Tote Box & CPU Holder Mounting Drawers and Tote Boxes are mounted using two steel strip drawer hangers which slide inside the worksurface support beams. Drawers should be installed before the worksurface assembly is mounted on the system. If the worksurface assembly is already in place, it should be removed for drawer installation. The worksurface is placed face down with one worksurface support bracket and two support beams loosely fastened to the top. For ease of assembly the drawers can be removed by releasing the disconnects on both sides of the slides and pulling the drawer forward to separate the slides. Fasten the two hangers (threaded inserts facing away from the drawer housing), loosely to the housing using the four 1/4"-20 x 1" machine screws provided. Slide the drawer hangers into the open end of the worksurface support beams. Install the remaining worksurface support bracket and tighten all hardware. Upright Trim Mount the two trim strips provided with a starter assembly one on each end of assembled system, by aligning trim with top of column and pressing it into place down the length of the column. Inside trim should be installed after light placement (so the power cord may be concealed between the trim and column), but before other accessories. Parabolic The 36" and 48" parabolics are installed using the two cap screws provided. The 60" & 72" parabolics are installed by first putting the end plates in place, by inserting it into the extruded slot of the light fixture. With both end plates in place, the parabolic may then be installed using the two cap screws provided. Fluorescent Fixture Remove the screws from the top of the light housing. Places the brackets as shown below and replace the screws. Mount the assembly at the desired height of the column. [. . . ] Recommended grounding procedures suggest installing an in-line 1 MEG OHM current limiting resistor between the static protected laminate and the ground. Electrical (Hydro) grounding circuits may not be at actual ground potential. It is recommended that a separate ground circuit be installed for the static protected worksurface. If your worksurface was not supplied with a factory drilled grounding location, use a 7/32" drill bit to drill into the worksurface in the desired location ensuring that no structure will obstruct the bolt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LISTAESCAN ARLINK 8000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LISTAESCAN ARLINK 8000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag