User manual LOOK SOLUTIONS UNIQUE 2 HAZER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LOOK SOLUTIONS UNIQUE 2 HAZER. We hope that this LOOK SOLUTIONS UNIQUE 2 HAZER user guide will be useful to you.

Lastmanuals help download the user guide LOOK SOLUTIONS UNIQUE 2 HAZER.


Mode d'emploi LOOK SOLUTIONS UNIQUE 2 HAZER
Download
Manual abstract: user guide LOOK SOLUTIONS UNIQUE 2 HAZER

Detailed instructions for use are in the User's Guide.

[. . . ] Operating manual 1 a Look Solutions product Set of Equipment supplied ­ ­ ­ ­ 1 Unique2 1 tank lid with quick connector, silicon tube and air valve filter 1 canister of UNIQUE-fluid, 2l 1 manual As an option: XLR remote for analogue control (delivered without cable) Diverter Case Hanging set Please check whether all the products you ordered are supplied. ­ ­ ­ ­ 2 Contents 1. Fluid 4. 1 General notes 4. 2 Changing the fluid canister 4. 3 Storage of the fluid 5. Operating the Unique2 5. 1 Selecting the location 5. 2 Putting into operation 5. 3 Switching the device off 5. 4 Control choices 5. 4. 1 Control via DMX 512 5. 4. 1. 1 Adjusting the DMX start address 5. 4. 1. 2 Adjusting the pump and the fan 5. 4. 2 Control via 0 - 10 Volt (+) DC 5. 4. 2. 1 Adjusting the pump and the fan 5. 4. 3 Stand alone mode 5. 4. 3. 1 Adjusting the pump and the fan 5. 4. 4 Control via Haze-Density Control System (HDCS) 5. 4. 4. 1 Using the Profile 5. 4. 5 Working with the internal Timer 5. 4. 5. 1 Autostart 5. 5 Wiring of the sockets 6. Warranty conditions 4 5 6 7 8 16 17 18 19 3 1. [. . . ] 5: Switching the device off You may control the Unique2 externally through the XLR sockets [2 and 3]. That means: when the machine is controlled via DMX 512 this data takes priority over 0-10V (+) DC and Stand alone operation. Please note: You can`t hold down the Mode-button for scrolling through the Menu. The Mode-button has to be pressed only momentarily. If the Mode-button is pressed more than two Seconds, the machine will change into the Timer-Mode (see point 5. 4. 5). An outstanding feature is the adjustable output of the Unique2. The pump and the fan can be easily and separately adjusted and regulated in 99 steps via buttons. Any desired effect can be achieved in steps of 1%: from the finest mist to a thick haze, similar to fog. To achieve the thickest effect the pump must run at 99%, the fan at 1%. The finest haze can be achieved with lower pump and higher fan settings. The data can be readjusted whenever you want to. 5. 4. 1 Operating via DMX 512 Connecting the Unique2 to a DMX desk, use the XLR socket [2] beside the control panel. As soon as the machine receives a correct DMX signal, the yellow DMXLED [19] will be lit. Please note: The Unique2 uses two channels on your desk!First Channel = Pump, second Channel =Fan 5. 4. 1. 1 Adjusting the DMX start address a) Press the Mode-button [14] at the control panel until three figures appear on the LED-display [17] (see Fig. Operating the Unique2 b) Adjust the required start address by pressing the Up- or Down-button [15]. c) Save the start address by pressing the Enter-button [16] once. The start address will now also be saved when you disconnect the machine from the mains supply. 5. 4. 1. 2 Adjusting the pump and fan output If you run the machine via a DMX desk you can adjust the pump and the fan directly from the desk from 1 to 99%. The adjusted channel controls the pump, the following one controls the fan. 5. 4. 2 0 - 10 Volt (+) DC control Connect the Unique2 to an analogue desk or the cable remote which you can get as an option, using the XLR socket at the back of the machine [3]. Please note: With analogue control the pump can be adjusted from the desk and/or the cable remote. The fan has to be adjusted at the machine. a) Put the cable from the desk or the cable remote into the XLR socket at the back of the machine [3]. b) Put the pump up to 99% and adjust the required fan output at the machine (see chapter 4. 4. 2. 1). [. . . ] The heating switches off and the machine cools down. Disconnect the machine from the mains supply for a moment and then re-connect it. E-8 appears on the LED display The vaporizer is clogged. Please send the machine to the service-station or your local dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOOK SOLUTIONS UNIQUE 2 HAZER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LOOK SOLUTIONS UNIQUE 2 HAZER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag