Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LOWRANCE X-55. We hope that this LOWRANCE X-55 user guide will be useful to you.
Lastmanuals help download the user guide LOWRANCE X-55.
Detailed instructions for use are in the User's Guide.
[. . . ] I. .
X-55
INSTALLATION AND OPERATION INSTRUCTIONS
LITHO IN U. S. A.
988-0136-07
L!® 12000 E. SKELLY DR. , TULSA, OK 74128
LOWRANCE ELECTRONICS, INC.
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
TABLE OF CONTENTS
INTRODUCTION MOUNTING POWER CONNECTIONS TRANSDUCER KEYBOARD BASICS DISPLAY MENUS HELP WINDOWS VIEWING WINDOWS OPTIONS MODIFYINGGROUPS RESETTING ALL GROUPS SIDESCANOPERATION SONAROPERATION AUTOMATIC SENSITIVITY RANGE Upper and Lower Limits ZOOM Automatic Operation ZOOM Manual Operation ALARMS FISHALARM ZONEALARM DEPTHALARMS ALARMMUTE
1 2 3 3
4
5
s
5
7 7
S
8 g 9 10
11
r
Cr
rr
N
1Ii
I
I FEET
45. 2
l.
°F
-
I
I
100
100
65+4
GROUP
11111
Al
100
GROUP "H"
ft
-
II
12 13 14 14 15 16 17 18 18 18 19 20
21 21 21
MENU-PAGE1
CHARTSPEED
GRAYLINE® FISH LD DISPLAYCONTRAST
ti'
i I!
'. ã
nL
GROUP
:1: --_-- 12
0
-- -- -- -- -- --
29 35 'IS
--I-- 60
HJII
GROUP "K"
MENU-PAGE2
ADJUST BACK LIGHTLEVEL BACKLIGHTON/OFF SPEAKER VOLUME TURN DIGITALBOX OFF CONSTRUCT DIGITAL BOX
SN'JI
MPH
21
II
I
MENU-PAGES CHARTCURSOR DISPLAY ZOOM BAR
DISPLAYZONEBAR DIGITALSONAR
MENU-PAGE4
FASTRAK SELECTUNITS OF MEASURE CLEAR DISTANCELOG
MENU-PAGES ADJUST CHARTSURFACE CLARITY ADVANCED SIGNALPROCESSING(ASP)
SIGNALINTERPRETATION TRANSDUCERS AND CONE ANGLES
FISHARCI-JES WATER TEMPERATURE ANDTHERMOCLINES SURVEYING ALAKE BAITFISH SONAR TROUBLESHOOTING
22 22 23 23 23 24 24 24 24 25 25 26 26 26 27 28 28 30
31
!QL?JL ·' · n :iteura':u
Oh
I
FEET I
n. --I--- r
. r -- a'a --
535°F
·ITnliM:4Pa
I UOLTS I
511 FT
A:r:'biIJ
12. 6 ----i
GROUP L"
r
FT
100
GROUP "M"
4@ag9
IUIW'
32 33
--INi
I
100·
I
Copyright5 1992 LowranceElectronics
°F
Allrightsreserved.
All featuresand specifications subjectto change withoutnotice. All screens in this manual are simulated.
6 5 +4 A!36. 5
GROUP"N"
37
GROUP"O"
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
WINDOWS SUMMARY All ofthewindowgroups used bytheX55 are shown on the following pages. To viewthese groups, simply press the WINDOWSkey, then repeated press the down arrow key. [. . . ] Typically, the best sensitivity level shows a good solid bottom signal with Graylineand somesurfaceclutter. Whenthe X-55 is in the Automaticmode, thesensitivity is automatically adjustedto keep a solid bottom signal displayed, plus a little more. This gives it thecapabilityto showfish and other detail. However, situations occur where it becomes necessary to increase or decreasethe sensitivity. This typically happens when you wish to see more detail, so an increase in sensitivity is indicated. The procedureto adjust it isthesamewhethertheunitis in the automatic or manual mode. Toadjustthe sensitivity, presstheSENSkey. Thesensitivity adjustmenu appearsat thebottom of the screen. The sensitivity menu has left and right arrows, plus a horizontal bar graph. The graph givesa visual indication of the sensitivity level. The number above the INC arrow also showsthe percentage of sensitivityin use. To increasethesensitivity level, press the right arrow key. As you press the key, the menu's bar graph will grow wider and thepercentage will increase in value. You canalso seethedifference on thechart record as it scrolls. When the sensitivity is atthe desired level,
release the key.
Tochange the ASP level, press the MENU key five times. Then press the key nextto the "ADJUST LEVELOF CHARTASP" labeluntil the desired level is obtained. SIGNAL INTERPRETATION Your X-55 gives an accurate picture of the bottom that your boat is passing. A bottom of firm sand, gravel, shell, or hard clay returns a fairly widesignal. Ifthe automatic mode isoff and thesignal narrows down, then it means thatyouhave moved overa mud bottom. Mud absorbsthesound wave and returns a weaksignal. Turn up the sensitivity to see a better
bottom signal. Big rocks or stumps on a smooth bottom send back signals above the bottom level signal. The height of the signal depends on the target's height. [. . . ] The percentage of chart speed in use changesas thearrow keysare pressed. The bar chart also gives a graphical indication of the chart speed. You can see the change onthescreen(both on the menu and on thechart record) as you pressthe keys. After you've made the adjustment, press the CLEAR key to erase the menu.
the GRAYLINE setting that's
best for you.
differentGRAYLINE level, also. Thelevel chosenbytheX-55atpoweron is usually adequatefor mostconditions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE X-55
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE X-55 will begin.