User manual LUMISCOPE MODEL 1097

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LUMISCOPE MODEL 1097. We hope that this LUMISCOPE MODEL 1097 user guide will be useful to you.

Lastmanuals help download the user guide LUMISCOPE MODEL 1097.


Mode d'emploi LUMISCOPE MODEL 1097
Download
Manual abstract: user guide LUMISCOPE MODEL 1097

Detailed instructions for use are in the User's Guide.

[. . . ] High blood pressure's dangerously strong correlation with cardiovascular disease has made measuring blood pressure a necessity for identifying those at risk. Blood Pressure Standard The World Health Organization (WHO) has developed a blood pressure standard, according to which areas of low- and high-risk blood pressure are identified. This standard, however, is a general guideline and blood pressures vary between different people, age groups, etc. It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk. 3 Blood Pressure Fluctuation Blood pressure fluctuates all the time! [. . . ] Do not dispose together with the household garbage. 4 Applying the Arm Cuff 1. Plug in the cuff connecting tube into the unit. Unwrap the arm cuff, leaving the "Index" end of the cuff through the D-ring of the cuff. 3. Put your left arm through the cuff loop. The "OK" range indication should be positioned closer to yourself with the rubber tube pointing in the direction of your arm. Position the artery mark ( ) over the main arteries (on the inside of your arm) in the upper arm. Tighten the cuff by pulling the "Index" end of the cuff. 4. Turn your left palm upward and place the edge of the arm cuff at approximately 2 to 3 cm above the inner side of the elbow joint. 5. If the Index line falls within the OK range, indicated at the edge of the cuff, this cuff is suitable for your use. If the Index line falls out of the OK range, you may need a special cuff for measurement. Please visit www. lumiscope. net or contact our service department at 1-800-672-8293 for more information regarding additional cuffs. 5 Taking a Measurement 1. EE mark shown on display or the blood pressure value is displayed excessively low (high) Did you talk or move during measurement?Correction Replace them with two new alkaline. Re-insert the batteries in the correct positions. Wrap the cuff properly so that it is positioned correctly. Measure it again quietly. Note: If the unit still does not work, return it to your dealer. Under no circumstance should you disassemble the unit and attempt repairs yourself. 7 Cautionary Notes: 1. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth. Do not iron or wash the cuff or use chemical cleaners on it. [. . . ] : Oscillometric : Pressure: 20~280mmHg; Pulse: 40~180 beats/ minute : Semi conductor : Pressure: ± 3mmHg; Pulse: ± 5% of reading : Pump Driven : Automatic Pressure Release Valve : 60-set memory : 1 minute after last button operation : Temperature: 10 °C ~ 40 °C (50 °F~104 °F); Humidity: 40 ~ 85% : Temperature: -5 °C ~ 60 °C ( 23 °F~140 °F ); Humidity: 10 ~ 95% : 6V DC four LR06 (AA) Batteries : 105 (L) X 160 (W) X 68 (H) mm : 360g(G. W. ) (No Batteries) : Adult: 22 ~32 cm (8. 7"~12. 6") (standard) : Large adult: 32 ~42 cm (12. 6"~16. 5") (optional) : Short time operation 2 minutes. *Specifications are subject to change without notice. Manufactured by: The Lumiscope Co. , Inc. 8 Two-Year Limited Warranty: Lumiscope guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase, except as noted below: This Lumiscope product warranty does not cover damage caused by misuse or abuse, the attachment of any unauthorized accessory, alteration to the product, or any other conditions whatsoever that are beyond the control of Lumiscope. Lumiscope shall not be responsible for any type of incidental, consequential, or special damage. All implied warranties, including, but not limited to those implied warranties of fitness and merchantability, are limited in the total duration of two years from the original date of purchase. To obtain warranty service on your Lumiscope Blood Pressure Monitor, please contact the Lumiscope Repair Department at 1-800-672-8293 or visit www. lumiscope. net. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LUMISCOPE MODEL 1097

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LUMISCOPE MODEL 1097 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag