[. . . ] Oxygen 88 User Guide
Oxygen 88
User Guide
1
1: Introduction
Congratulations on your purchase of the Oxygen 88, a premium 88-note, graded hammer-action, velocity-sensitive performance keyboard for studio and stage. Oxygen 88 features DirectLink, which provides support for qualified Digital Audio Workstations (DAW)1 such as Pro Tools. DirectLink automatically maps the track and master volume sliders, slider buttons, pan knobs, and transport controls to their corresponding functions in the application. A single USB connection not only sends MIDI data to the computer, but also provides power to the keyboard. [. . . ] Note Name A-1 Bb-1 G#2 A-1 A. -1 G. 2 LED Screen
Oxygen 88 Zone Channel:
User Guide
21
The Zone Channel (ZONE CHAN) function specifies which MIDI Channel a Zone will use when transmitting MIDI data. Assigning each Zone to its own channel will allow you to play up to 4 different sound patches on a connected synthesizer. This settings is saved as part of a User Patch when stored to a Memory Location. Select a Zone by pressing its Zone button. Press the Zone CHAN key - the LED screen will display the current Zone Channel number. Enter the new MIDI Channel number for the Zone using the number keys. Repeat steps 1 - 5 to assign set the MIDI channel for the remaining Zones.
After setting the Zone channel and exiting Advanced mode, activate all desired Zones by simultaneously pressing their respective Zone buttons. The following table shows the default Zone Channels. Zone 1 2 3 4 MIDI Channel 0 (Global Channel) 2 3 4
Assigning a Knob, Slider, Button, or Pedal jack to a Zone MIDI Channel (Z1 and Z4), causes that control to transmit MIDI data on the same MIDI Channel as the corresponding Zone.
Zone Octave
The Zone Octave (ZONE OCT) function allows the pitch of a Zone to be shifted up or down, in one octave increments, to a maximum of 10 Octaves. Select a Zone by pressing its Zone button. Press the Zone OCT key - the LED screen will display the current Octave shift value. Repeatedly press the "-" or "+" button to lower or raise the Octave shift value. Repeat steps 1 - 5 to set the octave shift for the remaining Zones.
After setting the Octave shift value and exiting Advanced mode, activate all desired Zones by simultaneously pressing their respective Zone buttons. Note: Zone Octave shift settings work in combination with the Global Octave shift setting (see Section 7, Octave / Transpose Buttons). This can be useful when working with different Octave or Transpose shift settings across multiple Zones. The Global Octave function shifts the entire keyboard up or down, while preserving relative pitch settings between Zones. For example, if a Zone is configured for an Octave shift of +1, and a Global Octave shift setting of +2 is applied to the keyboard, the effective octave shift for that Zone is +3.
22
User
Guide
Oxygen 88
Zone Transpose
The Zone Transpose function (ZONE TRAN) allows the pitch of a Zone to be shifted up or down in one semi-tone (halfstep) increments, to a maximum of 12 semi-tones. Select a Zone by pressing its Zone button. Press the Zone TRAN key - the LED screen will display the current Transpose value. Repeatedly press the "-" or "+" button to lower or raise the pitch. Repeat steps 1 - 5 to set the Transpose value for the remaining Zones.
After setting the Transpose value and exiting Advanced mode, activate all desired Zones by simultaneously pressing their respective Zone buttons. Note: Zone Transpose shift settings work in combination with the Global Transpose shift setting. [. . . ] Do not cover any cooling vents in the system. Avoid installing the system in a location where humidity, dust and fumes occur. Handle With Care Never use the system during abnormal conditions. Do not operate if no picture appears on the monitor, if smoke is emitted, sound is frequently deformed, or if there are any conditions of malfunction. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE M-AUDIO OXYGEN 88
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.