If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MA LIGHTING MIDI CONVERTER. We hope that this MA LIGHTING MIDI CONVERTER user guide will be useful to you.
Lastmanuals help download the user guide MA LIGHTING MIDI CONVERTER.
Manual abstract: user guide MA LIGHTING MIDI CONVERTER04-1995
Detailed instructions for use are in the User's Guide.
[. . . ] MIDI Converter
User's Manual
April 1995
Contents
1. Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the MIDI Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To change the Page of LC 12/24/48, simple commands are sufficient. To remote chaser, the chaser master, the chaser number and chaser ON/OFF should be programmed. When controlling switch memories or flash buttons of the memories of the Lightcommander, it is necessary to understand the MIDI commands of the Lightcommander: MIDI Lighting Control Desks transmit many MIDI commands or combinations e. g. Therefore all commands must be programmed separately (ON/OFF and many buttons at the same time). If you don't use more than one button at a time, flash buttons can be used very easily.
Please note the examples below!
6
MA Lighting Technology GmbH . www. malighting. de
MIDI Converter
Art. No. MA Lightcommander 24/6 fader controls MA Scancommander
Job: The memory C10 of the Scancommander shall be controlled by a fader value of 50 % of a Lightcommander: POS. CoCg 1 1 9 Data to remote the memory C10 of the Scancommander To guarantee the recognition of the value above 50 %, the ">" sign is set. Even when the fader is moved very fast, all values above 50 % will be recognized and thus memory C10 of the Scancommander will be called.
See also chapter 8: MIDI commands
Attention: The command will be repeated upon pulling the fader down again.
B. MA Lightcommander 24/6 SWITCH Memories control MA Scancommander
Job: Switch memories of Lightcommander 24/6 shall control different memories or sequences of the Scancommander (max. Attention: The switch memories should work in KILL mode to avoid double activation. CoCg 1 0 16 (Memory C10) (Sequence 15) (Memory A17)
Switch memories 1 to 3 (no page information is included here) Position 0 will activate memory C10 of the Scancommander by pressing switch memory 1 of LC 24. 15, position 2 activates memory A17.
See also chap. 8: MIDI commands
eMail: info@malighting. de . User's Manual MIDI Converter
7
C. Masterkeyboard controls MA Lightcommander 24 (Memories)
Job: Memory 10 of LC 24 shall be activated 100 % by pressing one key of the master keyboard. Releasing the key the memory shall switch off. CoCg 1 9 0
Brightness 100% Brightness 0%
Please read note (key number) in the user manual of the master keyboard Pos. 0 activates memory 10 of LC 24 100 % by a key value (velocity) > 1. The page of the Lightcommander will not be changed resp. the last MIDI page is still activated (no indication on page LEDs). Position 1 will set memory C10 to 0 % upon releasing the key. If the brightness of the memory is dependent on the velocity, please see the following data: POS. CoCg 1 9 ALL Here the second line is not necessary because the command ALL will transmit also the brightness value 0 %.
D. [. . . ] Do not put the unit on unstable tables etc. . Do not block the unit´s ventilation slots. Always insure adequate ventilation when installing the unit in a rack. The unit is provided with a safety plug. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MA LIGHTING MIDI CONVERTER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.