User manual MACKIE SP2400
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MACKIE SP2400. We hope that this MACKIE SP2400 user guide will be useful to you.
Lastmanuals help download the user guide MACKIE SP2400.
You may also download the following manuals related to this product:
MACKIE SP2400 DATASHEET (1002 ko)
MACKIE SP2400 QUICK GUIDE (352 ko)
Manual abstract: user guide MACKIE SP2400
Detailed instructions for use are in the User's Guide.
[. . . ] SP2400 Dual-Channel Program Controller/Amplifier
Instruction Manual
ZONE A
MASTER VOLUME
ZONE B
3 0 3 6 9 15 30 55
MASTER VOLUME
INPUTS
INPUTS
3 0 3 6 9 15 30 55
SP2400 MUSIC CONTROLLER
A B OVERLOAD
ON
1
2
3
4
1
2
3
4
OFF
OFF
STATUS
COMM PORT
POWER
115V 60Hz FUSE 115/T8A 220 WATTS 230V 50Hz FUSE 230/T4A 220 WATTS
DIRECT
PROGRAM INPUTS L
GROUND ALL CALL PARALLEL INPUTS
PAGING MIC
ZONE A ZONE B PHANTOM CONTROL
1234
SP2400 MUSIC CONTROLLER
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC "MACKIE. ", "MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED 1
SERIAL NUMBER
MANUFACTURING DATE
GAIN +40dB GAIN LOW
U
LOCAL
2 3 4
STEREO
G
+
HIGH
U
R
12345678 1234
PRIORITY
EXPANSION IN
EXPANSION OUT
1
2
3
4
OUTPUT
MONO
1
2
3
4
ON
-
+
12 +12
12 +12
CAUTION:
TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING
REMOTE
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. · WOODINVILLE · WA · MADE IN USA · FABRIQUE AU USA
ZONE B
STEREO RIGHT OUTPUT SUITABLE FOR CLASS 2 WIRING + 100/ 70V/8 I 0 12345678 AMP ADDRESS RS485 REMOTE
AMBIENT MIC
MIC/LINE INPUT B
PHANTOM GAIN +40dB
PAGING MIC VOX
PRE OUT G +
PROGRAM EQ
LOW 80Hz
U
ZONE A
STEREO LEFT HIGH 12k
U
3K
MIC/LINE INPUT A
PHANTOM GAIN +40dB
PAGING MIC VOX
PRE OUT G +
PROGRAM EQ
LOW 80Hz
U
MID
U
400
FREQ
1K
A
G
B
1
2
3
G
+
GAIN
LOW
U
HIGH
U
1234
OUTPUT SUITABLE FOR CLASS 2 WIRING + 100/ 70V/8
A G B 1 2 3 G +
MID
U
400
FREQ
1K 3K 250 8k
HIGH 12k
U
15 +15 15 +15
GAIN
LOW
U
HIGH
U
1234
15 +15 15 +15
I
250 8k
15 +15
-
+
12 +12 12 +12
-
+
0 12345678 AMP ADDRESS RS485 REMOTE
AMBIENT MIC
15 +15
AMP IN
-
+
12 +12 12 +12
-
+
AMP IN
CAUTION
AVIS
8. Power Sources -- Connect the SP2400 to a power supply only of the type described in these operation instructions or as marked on the rear panel. [. . . ] In addition, the paging mic and paging control signal are also provided on the EXPANSION bus. LOCAL/REMOTE is a set of eight DIP switches used to select the input source for the channel. Each program input has two switches, one to select the left signal source (odd-numbered switches) and one to select the right signal source (evennumbered switches). Move the switches up to select the local program source, and down to select the remote (external) program source from the EXPANSION bus. STEREO/MONO switches configure each input source for either stereo or mono operation. If the SP2400 is being used in a stereo configuration, leave the switches up. If it's being used in a zone configuration, move the switches down to combine the left and right channels for mono operation. PRE OUT is an unbalanced RCA jack that provides a line-level signal from the preamplifier stage of the SP2400. This provides a method for inserting an external signal processor into the signal chain prior to the amplifier stage. The U-shaped jumper wire should remain installed between the PRE OUT and AMP IN jacks for normal operation. AMP IN is an unbalanced RCA jack that accepts a line-level signal. ZONE A/ZONE B OUTPUTS are 2-pin Phoenixtype connectors that provide speaker-level signals. The SP2400 is shipped with the outputs configured for 70-volt operation in U. S. versions, and 100-volt operation in European versions. Internal jumpers are provided to configure the amplifier for 8 ohm systems as well. Connect the supplied AC linecord to the IEC AC Socket. The AC line fuse is contained in the socket, behind the cover located at the bottom of the socket. Use replacement fuses only as indicated on the rear panel.
115V 60Hz FUSE 115/ T8A 220 WATTS 230V 50Hz FUSE 230/ T4A 220 WATTS
DIRECT
PROGRAM INPUTS L
GROUND ALL CALL PARALLEL INPUTS
PAGING MIC
ZONE A ZONE B PHANTOM CONTROL
1234
SP2400 MUSIC CONTROLLER
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC "MACKIE. ", "MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED 1
SERIAL NUMBER
MANUFACTURING DATE
GAIN +40dB GAIN LOW
U
LOCAL
2 3 4
STEREO
G
+
HIGH
U
R
12345678 1234
PRIORITY
EXPANSION IN
EXPANSION OUT
1
2
3
4
OUTPUT
MONO
1
2
3
4
ON
-
+
12 +12
12 +12
CAUTION:
TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING
REMOTE
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. · WOODINVILLE · WA · MADE IN USA · FABRIQUE AU USA
ZONE B
STEREO RIGHT OUTPUT SUITABLE FOR CLASS 2 WIRING + 100/70V/8 I 0 12345678 AMP ADDRESS RS485 REMOTE
AMBIENT MIC
MIC/LINE INPUT B
PHANTOM GAIN +40dB
PAGING MIC VOX
PRE OUT G +
PROGRAM EQ
LOW 80Hz
U
ZONE A
STEREO LEFT HIGH 12k
U
3K
MIC/LINE INPUT A
PHANTOM GAIN +40dB
PAGING MIC VOX
PRE OUT G +
PROGRAM EQ
LOW 80Hz
U
MID
U
400
FREQ
1K
A
G
B
1
2
3
G
+
GAIN
LOW
U
HIGH
U
1234
OUTPUT SUITABLE FOR CLASS 2 WIRING + 100/70V/8
A G B 1 2 3 G +
MID
U
400
FREQ
1K 3K 250 8k
HIGH 12k
U
15 +15 15 +15
GAIN
LOW
U
HIGH
U
1234
15 +15 15 +15
I
250 8k
15 +15
-
+
12 +12 12 +12
-
+
0
12345678
15 +15
AMP IN
AMP ADDRESS
RS485
REMOTE
AMBIENT MIC
-
+
12 +12 12 +12
-
+
AMP IN
SP2400 5
3. Installation
Application Diagrams
Jukebox
Remote Control
Cassette or DAT Recorder
+3 0 3 6 9 15 30 55
Digital Satellite Service
CD Player
SP2400 SWITCH SETTINGS
INPUT 4 PRIORITY OFF/ON
Paging Mic
AMBIENT MIC OFF/ON
DOWN
1234
ZONE A
MASTER/SLAVE
To Telephone System Music-On-Hold
UP
I 0 12345678
ZONE B
OFF ON
230/115V 50/60 Hz FUSE 115/T8A
DIRECT
PROGRAM INPUTS
L L
PAGING MIC
GROUND ALL CALL PARALLEL INPUTS ZONE A ZONE
SP2400 MUSIC CONTROLLER
OFF ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC "MACKIE. ", "MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED 1
SERIAL NUMBER
MANUFACTURING DATE
B
GAIN +40dB GAIN LOW
U
PHANTOM CONTROL
I 0 12345678 AMP ADDRESS
LOCAL
1 2 3 4
LOCAL
2 3 4
STEREO
R
G
+
HIGH
U
12345678
1234
PRIORITY
1234
EXPANSION IN
EXPANSION OUT
1
2
3
4
OUTPUT
MONO
1
2
3
4
ON
-
+
12 +12
12 +12
CAUTION:
TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING
REMOTE
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. [. . . ] CAUTION: These servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Make sure the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP2400.
Connecting the RS485 Serial Port
This is a 3-pin Phoenix-type connector that follows standard RS485 protocol. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MACKIE SP2400 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MACKIE SP2400 will begin.