[. . . ] GENERATOR
G7300R G7301R
INSTRUCTIONS FOR USE
3ZZ9990180
ÉJÉi É_
FEDERAL EMISSIONS COMPONENT DEFECT WARRANTY
ENGLISH
EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE - This emission warranty is applicable in all States, except the State of California Makita U. S. A. Inc. , La Mirada, California, (herein "MAKITA") warrant(s) to the initial retail purchaser and each subsequent owner, that this Nonroad engine (herein "engine") has been designed, built, and equipped to conform at the time of initial sale to all applicable regulations of the U. S. Environmental Protection Agency (EPA), and that the engine is free of defects in materials and workmanship which would cause this engine to fail to conform with EPA regulations during its warranty period. For the components listed under PARTS COVERED, the Makita Factory Service Center or Service Center authorized by MAKITA will, at no cost to you, make the necessary diagnosis, repair, or replacement necessary to ensure that the engine complies with applicable U. S. [. . . ] Do not turn the key switch to "START" position when the engine is running to prevent damage of starting motor. When starting the engine by recoil starter, set the key switch at the "ON" position and pull the starter handle.
( g) After the engine started, return the choke lever gradually to "OPEN" position. (h) Warm up the engine without a load for a few minutes.
CHOKE LEVER OPEN CLOSE
12
USING ELECTRIC POWER
WARNING
Make sure that the appliance is switched OFF before connecting it to the generator. Do not move the generator while it is running. Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may lead to electrical shock.
ENGLISH
(1) AC APPLICATION (a) Check the voltmeter for proper voltage.
This generator is thoroughly tested and adjusted in the factory. If the generator does not produce the specified voltage, consult your nearest Makita factory or authorized service center.
(b) Turn off the switch (es) of the electrical appliance (s) before connecting to the generator.
13
(c) Insert the plug (s) of the electrical appliance(s) into the receptacle. Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current exceeding the specified amperage. Be sure that the total wattage of all appliances dose not exceed the rated output of the generator. (d) Turn the AC circuit breaker ON, and check if the pilot lamp light up.
ON
OFF
PILOT
LAMP
14
Style
Ampere up to 20A
Receptacle NEMA 5-20R NEMA L5-20R NEMA L5-30R NEMA L14-30R
TABLE 1
AC plug NEMA 5-20P NEMA L5-20P NEMA L5-30P NEMA L14-30P
Description
GFCI (Ground Fault Circuit Interrupter) Receptacle, duplex
ENGLISH
(REC1) Locking Receptacle (REC2) Locking Receptacle (REC2) Locking Receptacle (REC3)
up to 20A
up to 30A
up to 30A
WARNING
To take power out from the TWIST LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to the lock position. Be sure to ground the generator if the connected electrical device Is grounded. NOTE : When the AC circuit breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately, check the appliance and / or generator for overloading or detect and have repaired as necessary by Makita factory or authorized service center.
TWIST
CAUTION
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that other receptacles are not protected by GFCI. 15
GFCI RECEPTACLE After starting the engine, check the GFCI for proper functioning by the following test procedure. Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning properly. If TRIP dose not appear when testing, do not use the generator. To restore power, push RESET button.
WARNING
If the RESET button pops out during operation, stop the generator immediately and call a qualified electrician for checking generator and the appliances. FULL POWER SWITCH Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance. Refer to TABLE 2.
120V
120V 240V
CAUTION
Change the FULL POWER SWITCH after turning the AC circuit breaker to "OFF". [. . . ] Gasoline left in the fuel tank will eventually deteriorate making enginestarting difficult. Remove the drain screw of the carburetor. Check for loose bolts and screws, tighten them if necessary. Clean generator thoroughly with oiled cloth. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAKITA 7301R
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.