User manual MAXDATA MPL 1510 CASE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXDATA MPL 1510 CASE. We hope that this MAXDATA MPL 1510 CASE user guide will be useful to you.

Lastmanuals help download the user guide MAXDATA MPL 1510 CASE.


Mode d'emploi MAXDATA MPL 1510 CASE
Download
Manual abstract: user guide MAXDATA MPL 1510 CASE

Detailed instructions for use are in the User's Guide.

[. . . ] MAXDATA PLATINUM 1510R Server Chassis User`s Manual 2 Contents Contents 1 Chassis Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Feature Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Chassis Front Panel and Peripheral Bays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chassis Back I/O Ports and Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Also off when the system is powered off or in a sleep state. The amber status takes precedence over the green status. When the amber LED is on or blinking, the green LED is off. 8 Chassis Description Peripherals The chassis provides for a variety of peripherals that can be purchased separately and added to the system. The following describes the available options. Figure 5. Hard drive bays Flex bay Slim-line DVD/CD-ROM drive/FDD module HDD HDD Hard Disk Drives The chassis ships with two drive carriers for mounting HDDs in the hard drive bays. NOTE Drives can consume up to 17 watts of power each. Drives must be specified to run at a maximum ambient temperature of 50°C. Hot-Swappable SCSI Hard Drives In a SCSI system, the SCSI hard drives are hot swappable. When a drive fails, the SCSI backplane detects the failure, reports it, and powers down the failed drive. The drive fault LED shows a continuous amber light. After the failed drive is removed and a new drive is inserted, there is a short wait before power is applied to the drive and the drive fault LED becomes a blinking green light. Flex Bay In an ATA-based system, the flex bay can only be used with the optional DVD/FDD or CD-ROM/FDD module. If the DVD/CD-ROM/FDD module is not used, the flex bay is left empty. In a SCSI-based system, the flex bay can be used with either the optional DVD/FDD or CD-ROM/FDD module or a third hot-swappable SCSI HDD. The DVD/CD-ROM/FDD module may only be inserted or removed from the flex bay when system power is turned off. The DVD/CD-ROM/FDD module is NOT hot swappable. MAXDATA PLATINUM 1510R Server Chassis 9 Power Supply The power supply is rated for 350 watts of power at the following voltages: · · 100 ­ 127 volts (V)~ at 50/60 Hertz (Hz); 4. 96 amperes (A) maximum (max) 200 ­ 240 volts (V)~ at 50/60 Hertz (Hz); 2. 48 amperes (A) maximum (max) The power subsystem supports implementation of remote management features including remote enable that permits power to be activated from a variety of sources. System Cooling The chassis includes a non-hot-swappable fan module with five fans for cooling the processor(s), hard drives, and PCI cards. The fan system is located in the middle of the chassis to pull cooling air through the chassis. The power supply contains two built-in fans for cooling. Chassis Security To help prevent unauthorized access to the system's peripherals and control panel, a key locks the optional bezel to the front panel. You must provide additional, proper grounding for the rack and other devices installed in it. Overcurrent Protection: The server is designed for an AC line voltage source with up to 20 amperes of overcurrent protection. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server. If more than one server is installed in the rack, the power source for each server must be from a separate branch circuit. CAUTION Temperature: The operating temperature of the server, when installed in an equipment rack, must not go below 5°C (41°F) or rise above 35°C (95°F). Extreme fluctuations in temperature can cause a variety of problems in your server. Ventilation: The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling. It must also include ventilation sufficient to exhaust a maximum of 1200 Btu per hour for a fully loaded server. [. . . ] Lift the power supply out of the chassis. Place the edge connector end of the replacement power supply onto the chassis floor and slide it toward the front of the chassis until the edge connector is fully inserted in the power distribution board connector. Lower the rear of the power supply (B) and make sure that it is fully seated on the chassis floor and in front of the raised guides (C). Plug the power cord back into the power supply and the power source. Figure 10. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXDATA MPL 1510 CASE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXDATA MPL 1510 CASE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag