User manual MAXDATA MPL 510

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXDATA MPL 510. We hope that this MAXDATA MPL 510 user guide will be useful to you.

Lastmanuals help download the user guide MAXDATA MPL 510.


Mode d'emploi MAXDATA MPL 510
Download
Manual abstract: user guide MAXDATA MPL 510

Detailed instructions for use are in the User's Guide.

[. . . ] MAXDATA PLATINUM 510 Server User`s Manual 2 Contents Contents 1 Setting up the system System position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connecting the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Rear Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Powering up the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] [Yes] [No] If "Yes" is selected and the Enter key is pressed, all Setup fields are set to their default values. If "No" is selected and the Enter key is pressed, or if the ESC key is pressed, the user is returned to where they were before F9 was pressed without affecting any existing field values. <F10> Save and Exit - Pressing F10 causes the following message to appear: Setup Confirmation Save Configuration changes and exit now?[Yes] [NO] If "Yes" is selected and the Enter key is pressed, all changes are saved and Setup is exited. If "No" is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned to where they were before F10 was pressed without affecting any existing values. F6/+ <Enter> <Esc> <F9> Table 7 describes the on-screen options you will see in BIOS Setup and what they mean. Table 7. On-Screen Options When you see this: On screen, an option is shown but you cannot select it or move to that field. On screen, the phrase Press Enter appears next to the option. What it means: You cannot change or configure the option in that menu screen. Either the option is auto-configured or auto-detected, or you must use a different Setup screen. Press <Enter> to display a submenu that is either a separate full screen menu or a popup menu with one or more choices. The following sections describe the menus and options available in BIOS Setup. MAXDATA PLATINUM 510 Server 25 Hardware Monitoring The mainboard has an integrated Winbond Heceta 836327HF chip that is responsible for hardware monitoring. Together, the Winbond Heceta chip and the Intel® LANDeskTM Client Manager (LDCM) 6 software provide basic server hardware monitoring that alerts a system administrator if a hardware problem occurs. The LDCM software is for use with Windows® 2000 Server and Windows® 2000 Advanced Server operating systems. Other operating systems supported by the mainboard, such as NetWare 6. 0 or Red Hat Linux, will not be monitored with LDCM. Table 8 lists the monitored headers and sensors on the mainboard. Table 8. Monitored Headers and Sensors Sensor Type Voltage Item CPU1/2 1. 8 V VCC3 VCC +12 V 2. 5 V Vbat 5 VSB Fan Speed CPU1_FAN CPU2_FAN CHASSIS_FAN Temperature CPU1 CPU2 CHASSIS Description Monitors processor voltage (one CPU power plane) Chipset Monitors VCC3 Monitors VCC Monitors +12 V Monitors 2. 5 V (for DIMM) Battery pin voltage Monitors 5 VSB (5 V stand-by) Monitors primary processor fan speed Monitors secondary processor fan speed Monitors chassis fan speed through chassis fan header 3 only. (Total 4 chassis fans available) Monitors primary processor temperature Monitors secondary processor temperature Monitors chassis ambient temperature Serial ATA RAID BIOS Configuration NOTE To use the SATA RAID option, two SATA hard disk drives are required. Serial ATA on the mainboard is set to Base ATA mode by default. It must be changed to RAID mode before the RAID Configuration Utility can be used to configure Serial ATA RAID drives. Follow the instructions that come with this utility to change to RAID mode. 26 Configuration Software and Utilities RAID Configuration Utility The RAID Configuration Utility allows you to perform the following functions on Serial ATA drives: · · · · Create a RAID set using two SATA RAID drives Delete an existing RAID set Rebuild an existing mirrored set Resolve drive conflicts NOTE Before using the RAID Configuration Utility, set the BIOS to RAID mode. See Serial ATA RAID BIOS Configuration above. The RAID Configuration Utility can be entered only at boot-up time, while the system is in POST. To enter the utility, while the system is booting watch for the message: Press <Ctrl+S or F4> to enter RAID utility. [. . . ] If it becomes necessary to update the BIOS Boot Block, this jumper should be removed during the update process. These pins should be jumpered for normal operation. NOTE: This jumper should remain in place for normal BIOS operational code updates. Default 9-10 These pins are for normal operation. BIOS Recovery 3-4 CMOS clear BIOS Booblock Write Protect 5-6 7-8 NOTE The jumper should remain on pins 7 and 8 at all times until you are instructed to perform a BIOS Boot Block update. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXDATA MPL 510

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXDATA MPL 510 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag