Manual abstract: user guide MAXON DM-0530SERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] © 2010 Copyright Maxon Corporation. All rights reserved. 4 - 21. 4 - 8 E - i - 11/10 Duct burners - LV AIRFLO® Burner capacity versus gas pressure - LV-3, -4 & -5 AIRFLO® burners Capacity vs. gas pressure 3. 0 2. 5 Firing Rate Per Foot (MBtu/h) 2. 0 1. 5 1. 0 0. 5 0. 0 0 5 10 15 Gas Pressure ("wc) 20 25 30 Gas pressures are valid for use with natural gas with 1000 Btu/ft3(st) high heating value. Pressures are valid for burners with standard drilling (24 drillings/foot). [. . . ] © 2010 Copyright Maxon Corporation. All rights reserved. 4 - 21. 4 - 26 E - i - 11/10 Duct burners - LV AIRFLO® Designation LV-3G-6 LV-4D-6 LV-5D-6 LV-5B-6 Dimensions in inches unless stated otherwise Dimensions A A 6 LV-3G-12 LV-4D-12 LV-5D-12 LV-5B-12 B B 12 LV-3G-T LV-4D-T LV-5D-T LV-5B-T C C 12 LV-3G-X LV-4D-X LV-5D-X M 12 N 3. 5 LV-3G-12B LV-4D-12B LV-5D-12B LV-5B-12B 1 D 12 E 5 1) Connection for optional back inlet flange LV-3G-BX LV-4D-BX LV-5D-BX 1 M 12 N 3. 5 1) Connection for optional back inlet flange LV-3G-BH LV-4D-BH LV-5D-BH G 19. 44 H 12 J 4. 88 K 3. 72 1) Connection for optional back inlet flange 1 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. © 2010 Copyright Maxon Corporation. All rights reserved. Duct burners - LV AIRFLO® Optional back inlet flanges 4 - 21. 4 - 27 E - i - 11/10 For 12B and 36BH sections C Dimensions in inches unless stated otherwise A B C Size [1] 2" 0. 88 5. 75 3" 1. 75 5. 75 [1] Available in NPT or ISO threads For 12 x 12 BX sections C B Dimensions in inches unless stated otherwise A B C Size [1] 3" 3. 5 7 4" 3. 5 7 [1] Available in NPT or ISO threads www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. © 2010 Copyright Maxon Corporation. All rights reserved. 4 - 21. 4 - 28 E - i - 11/10 Duct burners - LV AIRFLO® End plates for Series LV-NP1 AIRFLO® burners All open ends of the burner assembly must be closed off with one of these end closures or pilots. (1) (2) (3) 1/8" NPT ------1-1/4" NPT --1/8" NPT 1-1/4" NPT 3/4" NPT 1/8" NPT --1/2" NPT 1/8" NPT --1/2" NPT 1/8" NPT --1/2" NPT SI conn. (4) ----14 mm 14 mm 14 mm 14 mm FR conn. (5) ----3/4" NPT 1/2" NPT 1/2" NPT 1/2" NPT FR alt. (6) ----1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT Pilot conn. (7) ------1/4" NPT 1/4" NPT 1/4" NPT Designation PLAIN END PLATE SET 1-1/4" END INLET FLANGE SET NPF 1-1/4" FR-SI 2-PC DS SET NP MINI-PAK PILT ASY W/SI, ORIF NP-PAK PILT SET W/SI, ETC NP-PAK PILT SET W/SI Sketch 1 2 3 4 4 4 A A C C 1 D 1 B 2 D B 2 A Z 35 6 4 1 2 D B A Z 35 6 4 7 1 B C 6 C E F G 6 E F G 3 D 4 H Sketch 1 2 3 4 A 6. 5 6. 5 6. 5 6. 5 B 0. 37 0. 81 0. 68 0. 78 Dimensions in inches unless stated otherwise C D E F 8. 06 3. 38 ----8. 06 3. 38 ----8. 06 3. 38 3. 12 1. 94 8. 06 3. 38 3. 12 1. 94 G ----1. 22 1. 09 H NPT ------3/8" Z [1] ----9. 5 9. 5 [1] Space for flame rod removal www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. G H 1. 0 0. 31 0. 69 1. 0 0. 16 4. 32 [1] 5. 12 [2] [1] From leading edge of mixing plates [2] From bottom of flange H www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. © 2010 Copyright Maxon Corporation. All rights reserved. 4 - 21. 4 - 34 E - i - 11/10 Duct burners - LV AIRFLO® Accessories/replacement items Direct mounted 14 mm spark ignitor for LV-NP1 AIRFLO® burners B A E C D Dimensions in inches unless stated otherwise A B C D E gap 14 mm thd. 2. 03 0. 38 1. 5 0. 062 Direct mounted 14 mm spark ignitor for LV-3, -4 & -5 AIRFLO® burners A E B C D Dimensions in inches unless stated otherwise A B C D E gap 14 mm thd. 2. 03 0. 38 1. 0 0. 062 Externally mounted spark electrodes for LV-3 AIRFLO® burners B A C D E F Dimensions in inches unless stated otherwise A B C D E F [1] 1/2"-14 5/16" hex 2. 5 0. 72 1. 03 18 thd [1] Maximum length - to be cut to the correct size for each application Externally mounted spark electrodes for LV-4 & LV-5 AIRFLO® burners C D A E G F B Dimensions in inches unless stated otherwise A B C DØ E F G gap 12 13. 8 18 19. 8 15/16" 1. 0 1. 562 0. 938 0. 062 hex 24 25. 8 36 36. 2 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. © 2010 Copyright Maxon Corporation. All rights reserved. Duct burners - LV AIRFLO® Quartz ignitor 4 - 21. 4 - 35 E - i - 11/10 Grip nut, o-ring seal, shield tube and ignitor nut are packaged separately to prevent damage to the quartz assembly during transit. The end user is responsible for final assembly of the quartz ignitor before installation. Dimensions in inches unless specified otherwise 1) Rubber cover 2) Grip nut 3) Ignitor nut 4) Shield tube 1. 0 Ø 5) 3/4-10 UNC 1 4 5 A 2 B 3 C Electrode 12" 18" 20" 24" 30" 36" 42" 48" A 1. 2 0. 83 1. 39 1. 39 0. 99 1. 64 0. 8 0. 8 B 12. 1 18. 5 19. 9 23. 9 30. 3 36. 7 42. 5 48. 5 C 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 Flame rod For those Series LV AIRFLO® burners using flame rods, most applications are covered by one of two sizes (specific number depends on nominal length "D" of rod extension). These may need to be cut to dimension "C" depending on your particular application. A B C D Dimensions in inches unless stated otherwise Burner model A B C D 7. 125 7. 125 LV-3G, -4D, -5D dir. 18 24 Division plate Provides isolation of burner feed(s) where desirable. This enables staging of burners for increased burner turndown. LV-NP1 LV-3, LV-4, LV-5 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. [. . . ] Do not bypass any of these safety interlocks. This will result in unsafe conditions. Process air flow Series LV AIRFLO® burners draw the required oxygen for combustion from the available process air flow across the burner. A correct fresh air flow across the burner is essential for safe operation of the burner, and should be safeguarded by a safety interlock (pressure switch or flow switch) as described in the applicable local codes or regulations. Refer to "Specifications" on page 4-21. 4-7 for more details or contact MAXON if you require further support. Pilot ignition Adjust pilot gas regulator to correct set point before pilot ignition attempt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXON DM-0530

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXON DM-0530 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag