User manual MAXSYS PC-4000 V1.3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXSYS PC-4000. We hope that this MAXSYS PC-4000 user guide will be useful to you.

Lastmanuals help download the user guide MAXSYS PC-4000.


Mode d'emploi MAXSYS PC-4000
Download
Manual abstract: user guide MAXSYS PC-4000V1.3

Detailed instructions for use are in the User's Guide.

[. . . ] Jan 11, 1993 Software Version 1. 3 Instruction Manual PC4OOO SECURITY SYSTEM INTRODUCTION The LCD-4500 keypad provides easy to understand English language information about the status of your security system and makes daily operation simple by prompting the user through each operation. The keypad provides audible feedback each time a key is pressed and with unique audible sequences it signals troubles and the correct or incorrect entry of information. ABOUT YOUR SECURITY SYSTEM Your DSC security equipment has been designed to give you the greatest possible flexibility and convenience. The LCD-4500 keypad will guide you through each operation with English language prompts. Read this manual carefully and have your installer instruct you on system operation and on which features have been implemented on your system. [. . . ] s Contrast Control adjusts the contrast of the lettering on the LCD display. Use the [<][>] keys to toggle through the eight different settings, and press [] to select the level of preference. BELL/COMM TEST []+[6]+[ACCESS CODE]+[4] This option allows the end user to test the system. The bell's and keypad buzzer's are activated for two seconds and a test code transmission will send to the monitoring station. DOOR CHIME []+[6]+[ACCESS CODE]+[5] The Door Chime feature is enabled or disabled by pressing the [] key to toggle from "N" to "Y" or "Y" to "N". When the chime zone is activated, the keypad will beep quickly 5 times. The "Beeping" on doors can be eliminated temporarily by using zone bypass, only when the panel is disarmed. MESSAGES []+[6]+[ACCESS CODE]+[6] This function enables two special event messages to be displayed when one of the special events occurs. The first message is "Fail to Arm". It will be displayed if the user is unable to arm the partition after entering a valid code (E. g. The second message is "Alarm When Armed". It will be displayed if an alarm occurred during the previous armed period. The messages are programmed by the installer. USER CALL UP []+[6]+[ACCESS CODE]+[7] This function must be enabled by the installer. When selected, the panel will call the downloading computer. The downloading computer must be waiting for the panel to call before downloading can be performed. Only use this function upon request from the installer. 7 VIEW PARTITIONS []+[6]+[ACCESS CODE]+[8] This function will allow the user to view the status of other partitions that their access code has been enabled for. For example, if an access code has been enabled for partitions 1, 2 and 5, they can only view the status of these partitions. To view the partitions status, press the [<] or [>] key to toggle through the partitions. The partition labels will be displayed along with a letter to the far right. The letter shows the status of that partition. A means the partition is Armed R means the partition is secure and Ready to be armed N means Not ready to be armed because zones are not secure. [. . . ] It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart "B" of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: n Re-orient the receiving antenna n Relocate the alarm control with respect to the receiver n Move the alarm control away from the receiver n Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXSYS PC-4000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXSYS PC-4000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag