User manual MAXTOR BASICS EXTERNAL DRIVE QUICK START

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR BASICS EXTERNAL DRIVE. We hope that this MAXTOR BASICS EXTERNAL DRIVE user guide will be useful to you.

Lastmanuals help download the user guide MAXTOR BASICS EXTERNAL DRIVE.


Mode d'emploi MAXTOR BASICS EXTERNAL DRIVE
Download
Manual abstract: user guide MAXTOR BASICS EXTERNAL DRIVEQUICK START

Detailed instructions for use are in the User's Guide.

[. . . ] The FIPS logo is a certification mark of NIST, which does not imply product endorsement by NIST, the U. S. , or Canadian governments. All other trademarks or registered trademarks are the property of their respective owners. No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC. Call 877-PUB-TEK1(877-782-8351) to request permission. [. . . ] There is no additional drain on the 12V supply. Savvio 10K. 3 SAS Product Manual, Rev. G 21 Table 2: 300GB standard drive DC power requirements 300GB standard model 3. 0 Gbit mode Notes (Amps) +5V [5] [1] [7] ±5% 0. 35 (Amps) +12V [2] ±5% [2] 0. 17 300GB standard model 6. 0 Gbit mode (Amps) +5V ±5% 0. 38 (Amps) +12V [2] ±5% [2] 0. 16 Voltage Regulation Avg idle current DC Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Peak operating current (random read): Typical DC Maximum DC Maximum (peak) DC Peak operating current (random write) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential read) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential write) Typical DC Maximum DC Maximum (peak) DC 3 3 3 3 3 3 3 3 [1] [6] [1] 3 3 3 [3] [3] [1] [4] 0. 60 0. 80 0. 56 1. 49 2. 02 0. 04 0. 61 0. 83 0. 60 1. 50 2. 02 0. 05 0. 48 0. 50 1. 12 0. 35 0. 36 1. 18 0. 49 0. 51 1. 18 0. 35 0. 36 1. 18 0. 53 0. 55 1. 06 0. 28 0. 29 1. 18 0. 55 0. 57 1. 10 0. 27 0. 28 1. 14 0. 87 0. 90 1. 16 0. 16 0. 16 0. 30 0. 90 0. 94 1. 20 0. 15 0. 15 0. 30 0. 83 0. 85 1. 08 0. 16 0. 16 0. 28 0. 84 0. 87 1. 08 0. 15 0. 15 0. 32 22 Savvio 10K. 3 SAS Product Manual, Rev. G Table 3: 146GB standard model DC power requirements 146GB standard model 3. 0 Gbit mode Notes (Amps) +5V [5] [1] [7] ±5% 0. 35 (Amps) +12V [2] ±5% [2] 0. 14 146GB standard model 6. 0 Gbit mode (Amps) +5V ±5% 0. 36 (Amps) +12V [2] ±5% [2] 0. 14 Voltage Regulation Avg idle current DC Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Peak operating current (random read): Typical DC Maximum DC Maximum (peak) DC Peak operating current (random write) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential read) Typical DC Maximum DC Maximum (peak) DC Peak operating current (sequential write) Typical DC Maximum DC Maximum (peak) DC 3 3 3 3 3 3 3 3 [1] [6] [1] 3 3 3 [3] [3] [1] [4] 0. 52 0. 77 0. 56 1. 18 2. 30 0. 04 0. 53 0. 82 0. 57 1. 19 1. 93 0. 06 0. 45 0. 48 1. 08 0. 36 0. 36 1. 18 0. 48 0. 52 1. 14 0. 33 0. 33 1. 16 0. 50 0. 52 0. 98 0. 26 0. 27 1. 18 0. 53 0. 56 1. 06 0. 24 0. 25 1. 18 0. 85 0. 88 1. 12 0. 16 0. 16 0. 28 0. 87 0. 92 1. 16 0. 13 0. 14 0. 26 0. 80 0. 83 1. 00 0. 16 0. 16 0. 30 0. 83 0. 87 1. 06 0. 13 0. 14 0. 28 [1] [2] [3] [4] [5] [6] [7] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. N (number of drives tested) = 6, 35 Degrees C ambient. For +12 V, a ­10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9, 936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator. This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive. See paragraph 7. 2. 1, "Conducted noise immunity. " Specified voltage tolerance includes ripple, noise, and transient response. Operating condition is defined as random 8 block reads. During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track. Savvio 10K. 3 SAS Product Manual, Rev. input/output operations per second 28 Savvio 10K. 3 SAS Product Manual, Rev. G 146GB models in 3 Gbit operation Typical power dissipation under idle conditions in 3Gb operation is 3. 43 watts (11. 70 BTUs per hour). To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 19). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3. 4123. Figure 21. 146GB (at 3 Gbit) DC current and power vs. input/output operations per second Savvio 10K. 3 SAS Product Manual, Rev. G 29 146GB models in 6 Gbit operation Typical power dissipation under idle conditions in 6Gb operation is 3. 48 watts (11. 87 BTUs per hour). To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 19). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3. 4123. Figure 22. 146GB (at 6 Gbit) DC current and power vs. input/output operations per second 7. 4 Environmental limits Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. [. . . ] Three +5 volt pins provide power to the drive, 2 short and 1 long. The current return for the +5 volt power supply is through the common ground pins. The supply current and return current must be distributed as evenly as possible among the pins. Current to the drive through the long power pins may be limited by the system to reduce inrush current to the drive during hot plugging. 12. 5 Signal characteristics This section describes the electrical signal characteristics of the drive's input and output signals. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR BASICS EXTERNAL DRIVE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR BASICS EXTERNAL DRIVE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag