User manual MAXTOR LYRION SERIES CE-ATA REV A 5-2008
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR LYRION SERIES CE-ATA. We hope that this MAXTOR LYRION SERIES CE-ATA user guide will be useful to you.
Lastmanuals help download the user guide MAXTOR LYRION SERIES CE-ATA.
Manual abstract: user guide MAXTOR LYRION SERIES CE-ATAREV A 5-2008
Detailed instructions for use are in the User's Guide.
[. . . ] Product Manual
Lyrion Series CE-ATA
ST760211CA ST730212CA
100441950 Rev. A May 2008
Revision history
Revision Date Sheets affected or comments
Rev. A
05/22/08
Initial release.
Copyright © 2008 Seagate Technology LLC. A May 2008 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. [. . . ] The drive does not incur any physical damage when subsequently put into operation. Table 5: Nonoperating random vibration profile.
Frequency (Hz) 2. 5 5 40 500 G2/Hz 1. 0 x E-03 3. 0 x E-02 1. 8 x E-02 1. 8 x E-02
2. 8. 7
Corrosive environment
Seagate electronic drive components pass accelerated corrosion testing equivalent to ten years of exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment. Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corrosive chemicals as electronic drive component reliability can be affected by the installation environment. The silver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or exposed to an ambient relative humidity greater than 95 percent. Materials used in cabinet fabrication, such as vulcanized rubber, that can outgas corrosive compounds should be minimized or eliminated. The useful life of any electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.
14
Lyrion CE-ATA Product Manual, Rev. A
2. 9
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). Discrete tone penalties are added to the A-weighted sound power (LW) with the following formula only when determining compliance: LWt(spec) == LW + 0. 1Pt + 0. 3 < 4. 0 (Bels) where LW = A-weighted sound power level pt == Value of discrete tone penalty [==dLt-6. 0 (dBA)] dLt = Tone-to-noise ratio taken in accordance with ISO 7779 at each octave band. All measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward. ) Table 6: Drive level acoustics
Acoustic mode Idle 1. 6 bels (typ) Operational 2. 2 bels (typ)
2. 10
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 7:
Test Radiated RF immunity
Electromagnetic immunity
Description 80 to 1, 000 MHz, 3 V/m, 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz ± 1 kV on AC mains, ± 0. 5 kV on external I/O ± 1 kV differential, ± 2 kV common, AC mains 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine 0% open, 5 seconds 0% short, 5 seconds 40%, 0. 10 seconds 70%, 0. 01 seconds Performance level A Reference standard EN 61000-4-3: 96 ENV 50204: 95
Electrical fast transient Surge immunity Conducted RF immunity Voltage dips, interrupts
B B A C C C B
EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94
Lyrion CE-ATA Product Manual, Rev. A
15
2. 11
Reliability
Specification 1 per 1014 bits read, max. 300, 000 software-controlled 20, 000 power loss 500 hours Per agreement
Measurement type Nonrecoverable read errors Load/Unload (LUL) cycles Power On Hours (POH) per year Warranty
16
Lyrion CE-ATA Product Manual, Rev. A
2. 12
2. 12. 1
Agency certification
Safety certification
The drives are recognized in accordance with UL60950-1, CAN/CSA-C22. 2 No. 60950-1, EN60950 and IEC 60950. 2. 12. 2 Electromagnetic compatibility
Hard drives that display the CE mark comply with the European Union (EU) requirements specified in the Electromagnetic Compatibility Directive (89/336/EEC). Testing is performed to the levels specified by the product standards for Information Technology Equipment (ITE). Emission levels are defined by EN 55022, Class B and the immunity levels are defined by EN 55024. Seagate uses an independent laboratory to confirm compliance with the EC directives specified in the previous paragraph. Drives are tested in representative end-user systems. [. . . ] A
Identify Device command
The Identify Device command returns a single block of data (512 bytes or 256 words) to the host, the relevant contents per the CE-ATA specification of which are as shown in the following table
Table 11:
Word 10-19 23-26 27-46
Identify Device commands
Description Serial number: (20 ASCII characters) Firmware revision (8 ASCII characters) Drive model number (40 ASCII characters) Major version number Bit 15 : Set to 1 Bits 14-2 : Reserved (0) Bit 1 : 1 = supports CE-ATA version 1. 0 Bit 0 : Set to 0 Maximum user LBA CE-ATA sector size CE-ATA Features Bits15-0 : Reserved (0) Integrity word Bits 15-8 : Checksum (as defined in ATA) Bits 7-0 : Signature (as defined in ATA) Value Drive serial number Current firmware revision (ASCII) ST730212CA (for 30GB) (ASCII) ST760211CA (for 60GB)
80
8002h
100-103 106 206
37E3E3Fh (for 30GB) 6FC7C7Fh (for 60GB) 000Ch 0000h
255
Lyrion CE-ATA Product Manual, Rev. A
27
4. 2. 3
Status and Control Registers
The Status and Control Registers (SCR) start at MMC register address 80h and can be accessed only by using CMD60 (RW_MULTIPLE_REGISTER) to read or write to them. The following SCR have been defined (RO = The register may be read only, RW = The register may be read or written to).
Table 12:
Index 0 1 2 6 16
Status and Control Registers
Byte Address 80h 84h 88h 98h C0h Name scrTempC scrTempMaxP scrTempMinP scrCapabilites scrControl R/W RO RO RO RO RW Description Current temperature reading Peak maximum temperature reading Peak minimum temperature reading Capabilities and features of the drive Control capabilities of the drive
The detailed description of each registers is as follows:
Byte Address 80h Name scrTempC Detailed description Bit 31 : Set to 1 (This register is supported) Bit 30 : If set to 1, indicates the values in bits 29-0 are valid If cleared to 0, indicates the values in bits 29-0 are invalid Bits 29-16 : Reserved (0) Bits 15-0 : Two's complement value of the number of degrees Celsius Bit 31 : Set to 1 (This register is supported) Bit 30 : If set to 1, indicates the values in bits 29-0 are valid If cleared to 0, indicates the values in bits 29-0 are invalid Bits 29-16 : Reserved (0) Bits 15-0 : Two's complement value of the number of degrees Celsius Bit 31 : Set to 1 (This register is supported) Bit 30 : If set to 1, indicates the values in bits 29-0 are valid If cleared to 0, indicates the values in bits 29-0 are invalid Bits 29-16 : Reserved (0) Bits 15-0 : Two's complement value of the number of degrees Celsius Bit 31 : Set to 1 (This register is supported) Bit 30 : If set to 1, indicates the values in bits 29-0 are valid If cleared to 0, indicates the values in bits 29-0 are invalid Bits 29-3 : Reserved (0) Bit 2 : Cleared to 0 (MMC data block size of 4KB is not supported) Bit 1 : Cleared to 0 (MMC data block size of 1KB is not supported) Bit 0 : Set to 1 (MMC data block size of 512 bytes is supported) Bit 31 : Set to 1 (This register is supported) Bit 30 : If set to 1, indicates the values in bits 29-0 are valid If cleared to 0, indicates the values in bits 29-0 are invalid Bits 29-2 : Reserved (0) Bits 1-0 : 00b (Default value, MMC data block size is 512 bytes)
84h
scrTempMaxP
88h
scrTempMinP
98h
scrCapabilites
C0h
scrControl
28
Lyrion CE-ATA Product Manual, Rev. A
5. 0
Internet
Seagate Technology support services
For information regarding Seagate products and services, visit www. seagate. com. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR LYRION SERIES CE-ATA Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR LYRION SERIES CE-ATA will begin.