User manual MAXTOR NL 35 FC REV D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR NL 35 FC. We hope that this MAXTOR NL 35 FC user guide will be useful to you.

Lastmanuals help download the user guide MAXTOR NL 35 FC.


Mode d'emploi MAXTOR NL 35 FC
Download
Manual abstract: user guide MAXTOR NL 35 FCREV D

Detailed instructions for use are in the User's Guide.

[. . . ] Product Manual NL35 Series FC ST3500071FC ST3400071FC 100343673 Rev. D August 2007 ©2007, Seagate Technology LLC All rights reserved. D August 2007 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. NL35 Series, SeaTools and SeaTDD are either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/or other countries. [. . . ] Typical power dissipation under idle conditions is 10. 75 watts (36. 68 BTUs per hour) during 2 Gbit operation. To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 2). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3. 4123. ST3500001FC DC CURRENT/POWER vs THROUGHPUT (1Gb) Random 8 Block Reads 1 . 800 1 . 600 1 . 400 1 . 200 1 8. 00 1 6. 00 1 4. 00 1 2. 00 1 0. 00 8. 00 6. 00 4. 00 2. 00 0. 00 0. 0 20. 0 40. 0 60. 0 80. 0 1 00. 0 1 20. 0 1 40. 0 1 60. 0 1 80. 0 5Vo lt A 1 Volt A 2 Watts Power (watts) Amperes 1 . 000 0. 800 0. 600 0. 400 0. 200 0. 000 I/Os per Second Figure 2. DC current and power vs. input/output operations per second (1 Gbit) ST3500001FC DC CURRENT/POWER vs THROUGHPUT (2Gb) Random 8 Block Reads 1 . 800 1 . 600 1 . 400 1 . 200 1 8. 00 1 6. 00 1 4. 00 1 2. 00 1 0. 00 8. 00 6. 00 4. 00 2. 00 0. 00 0. 0 20. 0 40. 0 60. 0 80. 0 1 00. 0 1 20. 0 1 40. 0 1 60. 0 1 80. 0 5Vo lt A 1 Volt A 2 Watts Power (watts) Amperes 1 . 000 0. 800 0. 600 0. 400 0. 200 0. 000 I/Os per Second Figure 3. DC current and power vs. input/output operations per second (2 Gbit) NL35 Series FC Product Manual, Rev. D 27 6. 4 Environmental limits Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58. 7°F (14. 8°C). Maximum wet bulb temperature is 82°F (28°C). Operating The maximum allowable continuous or sustained HDA case temperature for the rated MTBF is 122°F (50°C) The maximum allowable HDA case temperature is 60°C. Occasional excursions of HDA case temperatures above 122°F (50°C) or below 41°F (5°C) may occur without impact to specified MTBF. Continual or sustained operation at HDA case temperatures outside these limits may degrade MTBF. Provided the HDA case temperatures limits are met, the drive meets all specifications over a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 36°F (20°C) per hour. Air flow may be needed in the drive enclosure to keep within this range (see Section 8. 3). Operation at HDA case temperatures outside this range may adversely affect the drives ability to meet specifications. To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized. Non-operating ­40° to 158°F (­40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive. HDA Temperature Check Point 0. 5" Figure 4. Location of the HDA Temperature check point 6. 4. 2 Relative humidity The values below assume that no condensation on the drive occurs. Operating 5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour non-condensing. Non-operating 5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour non-condensing. 6. 4. 3 Effective altitude (sea level) a. Operating ­200 to +10, 000 feet (­61 to +3, 048 meters) b. [. . . ] Submit pricing requests, orders and returns through a single, password-protected Web interface-anytime, anywhere in the world. spp. seagate. com spp. seagate. com supports Seagate resellers with product information, program benefits and sales tools. You may register for customized communications that are not available on the web. These communications contain product launch, EOL, pricing, promotions and other channel-related information. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR NL 35 FC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR NL 35 FC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag