[. . . ] Series Nine
ELECTRIC WATER HEATER USER'S GUIDE
Model Numbers
HRE2930T HRE3930T HRE2940L HRE3940L HRE2940S HRE3940S HRE2940T HRE3940T HRE2950S HRE3950S HRE2950T HRE3950T HRE2966T HRE3966T
FOR POTABLE WATER HEATING ONLY
GAMA certification applies to all residential electric water heaters with capacities of 20 to 120 Gallons. Input rating of 12 Kw or less at a voltage no greater than 250 V.
NOT SUITABLE FOR SPACE HEATING Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product.
Part No. 66001711 184741-000
WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. Save this Manual for Future Reference.
Printed in the U. S. A. [. . . ] Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch. Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker. Refer to the chart in the "Product Specifications" section for the correct size wire and fuse or circuit breaker. If metal conduit is used for the grounding conductor: A. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum. The material shall be of one continuous length without a splice or joint. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding.
WIRE NUTS CONDUIT
17
GREEN GROUND SCREW
Instructions for Installation (cont'd)
Installation Checklist
1. Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel. Is the fuse or circuit breaker size correct as shown in the chart in the "Product Specifications" section?
CONDUIT
HOT
COLD
HOT
COLD
3. Are the wires from the circuit breaker or fuse service to the water heater's junction box on the correct wire size (gauge) as shown in the chart in the "Product Specifications" section?Is the new temperature-pressure relief valve properly installed, and piped to an adequate drain?See "Temperature-Pressure Relief Valve" in the "Instructions for Installation" section. Is the water heater completely filled with water?See "Filling the Water Heater" instructions in the "Instructions for Installation" section. See "Locating the New Water Heater" in the "Instructions for Installation" section. Are the cold and hot water lines connected to the water heater correctly?See "Water Piping" instructions in the "Instructions for Installation" section. Is there adequate clearance for maintenance around the water heater?Do you need to call your electric company to check your wiring?
TEMPERATUREPRESSURE RELIEF VALVE
DISCHARGE PIPE (Do not cap or plug)
6 AIR GAP
FLOOR DRAIN
MODEL RATING PLATE
18
Service and Maintenance
Temperature Regulation
WARNING
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. [. . . ] 21 23 3
22 20
1 19 15 17 16 9 18 2
8 6 10 9 11 14 12 13 32 7 4 5
Repair Parts List (cont'd)
MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRE2950S 50 GALLON HRE3950S 50 GALLON HRE2950T 50 GALLON HRE3950T 50 GALLON HRE2966T 66 GALLON HRE3966T 66 GALLON MODEL NUMBERS HRE2950T HRE3950T PART NUMBERS 66001700 66001700 -- -- 66001702 66001702 66001015 66001015 66001021 66001021 66001053 66001053 SEE NOTE ON PAGE 32 66001055 66001055 66001054 66001054 66001007 -- 66001268 -- -- 66001008
KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 #
PART DESCRIPTION Temperature-Pressure Relief Valve T&P Insulation Dip Tube Drain Valve Drain Valve Washer 17 /32 x 13/64 x 1/8 thick)* Element Gasket Lower Element Buss Bar Kit Thermostat Bracket 2 Pole Thermostat (Two Wire Lead Models) Terminal Cover (Lower) Lower Thermostat w/Hi Limit (Three Wire Lead Models) Terminal Cover (Lower Three Wire) Lower Access Panel Upper Access Panel Terminal Cover (Upper) Upper Thermostat w/Hi Limit Upper Element Element Gasket Primary Anode Secondary Anode/Nipple w/Heat Traps Nipple w/Heat Traps Pipe Insulation Manual
HRE2950S 66001700 66001709 66001544 66001015 66001021 66001053 66001055 66001054 66001007 66001268 -- -- 66001703 66001703 66001064 66001009 66001053 66001726 66001217 66001707 66001709
HRE3950S 66001700 66001709 66001544 66001015 66001021 66001053 66001055 66001054 -- -- 66001008 66001272 66001703 66001703 66001064 66001009 66001053 66001726 66001217 66001707 66001709
HRE2966T 66001700 -- 66001702 66001015 66001021 66001053 66001055 66001054 66001007 66001268 -- -- 66001703 66001703 66001064 66001009 66001053 66001733 66001217 66001707 66001709
HRE3966T 66001700 -- 66001702 66001015 66001021 66001053 66001055 66001054 -- -- 66001008 66001272 66001703 66001703 66001064 66001009 66001053 66001733 66001217 66001707 66001709
-- 66001272 66001703 66001703 66001703 66001703 66001064 66001064 66001009 66001009 SEE NOTE ON PAGE 32 66001053 66001053 66001727 66001727 66001720 66001720 66001705 66001705 66001709 66001709 66001711
*Also available at most hardware stores. Refer to Wiring Diagram Section for verification. #Not Illustrated
Now that you have purchased this water heater, should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRE3940S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.