[. . . ] Series Ten
ELECTRIC WATER HEATER USER'S GUIDE
Model Numbers
HRX30DERT HRX40DERS HRX40DERT HRX52DERS HRX52DERT HRX66DERT HRX82DERT
FOR POTABLE WATER HEATING ONLY
GAMA certification applies to all residential electric water heaters with capacities of 20 to 120 Gallons. Input rating of 12 Kw or less at a voltage no greater than 250 V.
NOT SUITABLE FOR SPACE HEATING Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product.
Part No. 184742-000 66001712
WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. Save this Manual for Future Reference.
Printed in the U. S. A. [. . . ] A green ground screw has been provided on the water heater's junction box. Replace the wiring junction cover using the screw provided.
WARNING
WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equipped for one type voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any voltage other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company.
CAUTION
If wiring from your fuse box or circuit breaker box was aluminum for your old water heater, replace it with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the water heater made by a competent electrician. Call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer. Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch. Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker. Refer to the chart in the "Product Specifications" section for the correct size wire and fuse or circuit breaker. If metal conduit is used for the grounding conductor: A. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum. The material shall be of one continuous length without a splice or joint. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding.
WIRE NUTS CONDUIT
13
GREEN GROUND SCREW
Instructions for Installation (cont'd)
Installation Checklist
1. Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel. Is the fuse or circuit breaker size correct as shown in the chart in the "Product Specifications" section?
CONDUIT
HOT
COLD
HOT
COLD
3. Are the wires from the circuit breaker or fuse service to the water heater's junction box on the correct wire size (gauge) as shown in the chart in the "Product Specifications" section?Is the new temperature-pressure relief valve properly installed, and piped to an adequate drain? [. . . ] Refer to model rating plate for wattage of non-standard lower and upper elements. Give voltage and element wattage when ordering replacement parts. 4 21 2 1
3
22 5 20 19 16 18 17 10
8 11 12 15 13 14 10 9 6 7
26
Repair Parts List (cont'd)
MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRX30DERT 30 GALLON HRX40DERT 40 GALLON HRX52DERT 50 GALLON HRX66DERT 66 GALLON HRX82DERT 80 GALLON
KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 #
MODEL NUMBERS PART HRX30DERT HRX40DERT HRX52DERT HRX62DERT HRX82DERT DESCRIPTION PART NUMBERS Primary Anode 9001834 9001829 9001672 9003729 9003932 Nipple w/Heat Traps 9003931 9003909 9003931 9003915 9003936 Dip Tube 9003501 9003929 9003919 9003919 9003929 Secondary Anode 9003965 9003966 9003965 9003934 9003935 and Nipple w/Heat Traps Temperature-Pressure Relief Valve 9001583 9001583 9001583 9001583 9001583 Drain Valve 9001588 9001588 9001588 9002401 9002401 Drain Valve Washer 9001584 9001584 9001584 9001584 9001584 17 /32 x 13/64 x 1/8 thick)* Element Gasket 9000308 9000308 9000308 9000308 9000308 Lower Element SEE NOTE ON PAGE 26 Thermostat Bracket 9000309 9000309 9000309 9000309 9000309 2 Pole Thermostat 9000507 9000507 9000507 9000507 9000507 (Two Wire Lead Models) Terminal Cover (Lower) 9002276 9002276 9002276 9002276 9002276 Lower Thermostat w/Hi Limit 9000509 9000509 9000509 9000509 9000509 (Three Wire Lead Models) Terminal Cover (Lower Three Wire) 9002303 9002303 9002303 9002303 9002303 Lower Access Panel 9003900 9003900 9003900 9003900 9003900 Upper Access Panel 9003900 9003900 9003900 9003900 9003900 Terminal Cover (Upper) 9002438 9002438 9002438 9002438 9002438 Upper Thermostat w/Hi Limit 9001954 9001954 9001954 9001954 9001954 Upper Element SEE NOTE ON PAGE 26 Element Gasket 9000308 9000308 9000308 9000308 9000308 Pipe Insulation 9003717 9003717 9003717 9003717 9003717 T&P Insulation 9003716 9003716 9003716 9003716 9003716 Manual 184742-000
* Also available at most hardware stores. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRX40DERS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.