[. . . ] Series Six
POWER VENT GAS WATER HEATER USER'S GUIDE
FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers
HV640YBVIT HV650YBVIT HV640HBVIT HV650HBVIT
· · · · · ·
Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List
C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER.
PRINTED IN THE U. S. A. 0906
www. maytagwaterheaters. com 1
PART NO. 185374-001
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. [. . . ] Condensation in the venting system of power vented water heaters is dependent upon installation conditions including, but not limited to ambient temperature and humidity of installation location, ambient temperature and humidity of venting space, vent discharge and slope, and product usage. In certain conditions, installations in unconditioned space or having long horizontal or vertical vent runs may accumulate condensate. In these conditions, the vent pipe should be sloped downward away from the blower assembly 1/4" (6. 4 mm) per five feet (1. 5 m) of pipe but not more than 1 1/2" (3. 8 cm) in the total vent length. If the vent piping is vented level or sloped upwards away from the blower assembly, then adequate means for draining and disposing of the condensate needs to be made by the installer (if condensate is detected). If you have condensate, then a 3/8" drain hose can be connected to the built-in drain port of the rubber boot on the blower assembly. For your convenience, the rubber boot is supplied with a removable cap on the built-in drain port. Prior to operating the water heater, make sure the removable cap is installed on the drain port (if a drain hose is not needed).
MAXIMUM VENT LENGTHS
40, 000 BTU Units: For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12. 2 m). This does not include the supplied vent termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 3" Venting, the maximum equivalent feet of pipe allowed is 120 feet (36. 6 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48. 8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2. 4 m). One 45° elbow is approximately equal to 4 feet (1. 2 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. 50, 000 BTU Units: For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12. 2 m). [. . . ] Unit shuts down and in lockout.
ABC
ABC
ABC
Unit shuts down.
ABC
Unit shuts down and in lockout.
TROUBLESHOOTING GUIDELINES
These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a "Flammable Vapor Ignition Resistant" Product.
31
REPAIR PARTS LIST
MAYTAG GAS WATER HEATER MODEL NO'S 40 Gallon Natural Gas 50 Gallon Natural Gas 40 Gallon Propane (L. P. ) 50 Gallon Propane (L. P. )
HV640YBVIT HV650YBVIT HV640HBVIT HV650HBVIT
BURNER ASSEMBLY OUTER DOOR (ALTERNATE)
1
Part Description HV640YBVIT Burner Assembly TBD Burner Head 66001494 Burner Orifice TBD Burner Tube TBD HSI Ignition Assembly TBD Inner Door 66001499 Inner Door Gasket 66001500 Flue Baffle TBD Flue Restrictor 66001513 Blower Assembly TBD Air Intake Screen - Base Pan 66001503 Inlet Tube 66001646 Gas Control Valve TBD Drain Valve 66001016 Drain Valve Washer 66001021 Outer Door TBD Anode Rod TBD Temperature-Pressure Relief Valve 66001079 Viewport Assembly 66001509 20" Dia. Drain Pan w/Side Drain (optional) TBD 22" Dia. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HV640YBVIT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.