[. . . ] Series Twelve
POWER VENT GAS WATER HEATER USER'S GUIDE
FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers
HVN41240PCGA HVN41250PCGA HVN41250VCGA HVP41240PCGA HVP41250PCGA HVP41250VCGA
CANADIAN MANUAL · · · · · · Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List
C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER.
PRINTED IN THE U. S. A. 1005
www. maytagwaterheaters. com 1
PART NO. 185380-000
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. [. . . ] This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48. 8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2. 4 m). One 45° elbow is approximately equal to 4 feet (1. 2 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. 50, 000 BTU Units: For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12. 2 m). This does not include the supplied Vent Termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 3" Venting, the maximum equivalent feet of pipe allowed is 120 feet (36. 6 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48. 8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2. 4 m). [. . . ] Unit shuts down and in lockout.
ABC
ABC
ABC
Unit shuts down.
ABC
Unit shuts down and in lockout.
TROUBLESHOOTING GUIDELINES
These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a "Flammable Vapor Ignition Resistant" Product.
30
REPAIR PARTS LIST
MAYTAG GAS WATER HEATER MODEL NO'S HVN41240PCGA HVN41250PCGA HVN41250VCGA HVP41240PCGA HVP41250PCGA HVP41250VCGA 40 Gallon Natural Gas 50 Gallon Natural Gas 50 Gallon Natural Gas 40 Gallon Propane (L. P. ) 50 Gallon Propane (L. P. ) 50 Gallon Propane (L. P. )
BURNER ASSEMBLY OUTER DOOR (ALTERNATE)
1
Key No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 **20
16
HVP41250P HVP41250V TBD TBD TBD TBD 66001540 66001571 TBD TBD TBD TBD 66001498 66001498 66001500 66001500 TBD TBD 66001513 66001513 TBD TBD 66001503 66001503 66001520 66001520 TBD TBD 66001015 66001015 66001021 66001021 TBD TBD TBD TBD 66001216 66001216 66001509 66001509 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD
Model Numbers Part Description HVN41240P HVN41250P HVN41250V HVP41240P Burner Assembly TBD TBD TBD TBD Burner Head 66001494 66001494 66001494 TBD Burner Orifice TBD TBD 66001778 66001540 Burner Tube TBD TBD TBD TBD HSI Ignition Assembly TBD TBD TBD TBD Inner Door 66001499 66001498 66001498 66001499 Inner Door Gasket 66001500 66001500 66001500 66001500 Flue Baffle TBD TBD TBD TBD Flue Restrictor 66001513 66001513 66001513 66001513 Blower Assembly TBD TBD TBD TBD Air Intake Screen - Base Pan 66001503 66001503 66001503 66001503 Inlet Tube TBD 66001520 66001520 TBD Gas Control Valve TBD TBD TBD TBD Drain Valve 66001015 66001015 66001015 66001015 Drain Valve Washer 66001021 66001021 66001021 66001021 Outer Door TBD TBD TBD TBD Anode Rod 66001727 TBD TBD 66001727 Temperature-Pressure Relief Valve 66001216 66001216 66001216 66001216 Viewport Assembly 66001509 66001509 66001509 66001509 20" Dia. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HVN41240PCGA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.