If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIDAS CONSOLES MIDAS SIENA. We hope that this MIDAS CONSOLES MIDAS SIENA user guide will be useful to you.
Lastmanuals help download the user guide MIDAS CONSOLES MIDAS SIENA.
Manual abstract: user guide MIDAS CONSOLES MIDAS SIENA
Detailed instructions for use are in the User's Guide.
[. . . ] OPERATORS MANUAL
Telex Communications (UK) Ltd, Klark Teknik Building, Walter Nash Road, Kidderminster. Tel:+44 1562 741515 Fax:+44 1562 745371 Website: www. midasconsoles. com
MIDAS Siena audio mixing console DOC02-Siena Issue 1. 0 - Janruary 2005 © Telex Communciations (UK) Ltd.
In line with the company's policy of continual improvement, specifications and function may be subject to change without notice. This Operators Manual was correct at the time of writing. E&OE.
Important Safety Instructions
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE AVIS: RISQUE DE CHOC ELECTRIQUE. [. . . ] Each of these circuits is individually routed to the talk bus, and combined with the tone generator if it is enabled. The combined talkback and tone signals may then be routed to any of the console's 16 mix bus and stereo master outputs using the 'talk to mix' and 'talk to masters' switches shown below. Note: to route only talkback to a mix bus output or stereo master, without the tone generator, make sure that the Generator On switch is disabled.
500
right
21 18 15 12 9 6 3
direct input
0
150
MUTE
50 20 5k 0
SOLO
frequency
In addition to routing talkback to the console's mix bus and master outputs, the talk out circuit available on the rear panel of the master section, provides an output of the talk bus enabling the combined talkback and tone signals to be output to an external communications system.
0
direct to masters
10
generator
6
talk mic
3
15
60
talk gain
talk on 1-2 3-4 5-6
talk ext
auto mute masters
input
1
7-8 9-10 11-12 13-14 15-16
3
4
input / output
5
masters
Talk On When depressed, the internal talk mic input is enabled and routed to the talk bus. In addition, all local monitor outputs are attenuated by 20dB to help prevent feedback.
15
60
talk gain
talk on 1-2 3-4
talk ext
auto mute masters
input
monitor
add clear phones
0
1
SOLO
SOLO
input
PFL
output
PFL MUTE
10
auto mute
local
mono sum
MUTE
5
MUTE
5
MUTE
Talk to Mix Bus Outputs (1-2, 3-4, etc. ) The 16 talk to mix switches route the combined talkback and tone generator signals individually to each of the console's 16 mix busses.
5-6
2
7-8 9-10 11-12 13-14 15-16
3
4
input / output
left
SOLO
right
SOLO
mono
MUTE
masters
10
stereo
10
5
5
Talk to Masters The masters switch routes the combined talkback and tone generator signals to the console's stereo master.
5
masters
0
0
5
5
10 15 20 30 40
10 15 20 30 40
S0011
Operators Manual - Page 21
NEUTRIK
2
2
3
1
NEUTRIK
2
1
Talk Mic Gain The gain of the internal talk mic input is continuously variable from +15dB to +60dB.
talk mic
Talk Mic The internal talk mic socket is a conventionally wired XLR male and is supplied with 48V phantom power allowing the connection of condenser microphones for engineer talkback. Talk External The talk ext switch enables both the talk in and talk out connections on the rear panel of the master section. This adds the external talkback source connected to the talk in XLR to the talk bus. It also activates the talk out connection providing an output feed from the talk bus.
Master Section:
master meters
left
21 18 15 12 9 6 3 0 3 6 9 12 15 18 21 24 0 3 6 9 12 15 18 21 24
Stereo Master & Monitoring Controls
right
21 18 15 12 9 6 3
Auto Mute Masters
The Siena provides five auto mute groups commonly used to provide easy muting of similar channels. For example:
solo meters
left
21 18 15 12 9 6 3 0 3 6 9 12 15 18 21 24 0 3 6 9 12 15 18 21 24
right
21 18 15 12 9 6 3
Channels Drum Mics Choir Overheads Orchestra Parts
Reason Allows the engineer to mute the whole drum kit at once. Allows the engineer to quickly remove all choir mics at once Allows the engineer to zone mics together (e. g. Brass, Strings, etc. ) and mute sections together if they were not playing.
Any input channel may be assigned to auto mute groups 1-4; both input channels and mix bus masters may be assigned to group 5, therefore, you may wish to reserve this group for dealing with output mute functions. For example, when using the console to run monitors during a live concert, there may be one song where most of the band will leave the stage. During this part of the show, monitor sends are only needed for one or two performers. By selecting auto mute 5 on all of the other band members' auxiliary send masters, you may mute these monitor feeds with one switch press auto mute master 5. The auto mute master switches located in the master section activate each auto mute group as follows:
direct input
0
150
500
MUTE
50 20 5k 0
SOLO
frequency
0
direct to masters
10
generator
6
talk mic
3
15
60
talk gain
talk on 1-2 3-4 5-6
talk ext
1
15 60
2
7-8 9-10 11-12 13-14 15-16
talk gain
3
talk on 1-2 3-4 5-6
talk ext
auto mute masters
input
4
input / output
1
5
masters
monitor
add clear phones
0
2
7-8 9-10
SOLO
SOLO
input
PFL
output
PFL MUTE
3
10
11-12 13-14
auto mute
local
mono sum
MUTE
4
input / output
5
MUTE
5
MUTE
15-16
left
SOLO
right
SOLO
mono
MUTE
5
masters
masters
10
stereo
10
5
5
0
0
5
5
10 15 20 30 40
10 15 20 30 40
S0011
Operators Manual - Page 22
NEUTRIK
2
1
input
3
auto mute masters
NEUTRIK
2
1
talk mic
Auto Mute Masters 1, 2, 3, 4 & 5 Press the corresponding auto mute master switch to mute all input channels and/or bus masters included within the auto mute group (1 through 5). The auto mute master status is indicated by the corresponding LED. Note: don't forget to check the status of your auto mute masters and auto mute group assignments carefully, as any mutes on assigned input channels or bus outputs will not be released until the auto mute master is disabled!
Master Section:
master meters
left
21 18 15 12 9 6 3 0 3 6 9 12 15 18 21 24 0 3 6 9 12 15 18 21 24
Stereo Master & Monitoring Controls
right
21 18 15 12 9 6 3
Local Monitoring and Headphone Outputs
The Siena provides local stereo and mono monitor outputs, stereo headphone and separate PFL output. Typically, each of these outputs is provided for the following applications: Output Local Monitor L/R Local Monitor M Headphone (Phones) PFL Out Format Stereo Mono Stereo Mono Connection Rear Panel Rear Panel Arm Rest Rear Panel console. Application For connection of local stereo loudspeakers. For connection of a local mono loudspeaker. For linking the PFL output of the Siena to another
solo meters
left
21 18 15 12 9 6 3 0 3 6 9 12 15 18 21 24 0 3 6 9 12 15 18 21 24
right
21 18 15 12 9 6 3
direct input
0
150
500
Tip: when running monitors, you may wish to listen to your mono floor monitor feeds on a separate speaker to your stereo in-ear monitoring so that you know what the artist is hearing from each system. Connect a pair of stereo speakers to the Local Monitor L/R output and a separate mono speaker to the Local Monitor M output. Now solo the mix bus masters feeding both the in-ear monitoring and floor monitors. [. . . ] Alternative Outputs When mixing for a number of speakers in a venue, it may be necessary to generate separate mixes with different levels or processing. Route the input channels to the chosen mix bus sends, let's say mix busses 9 and 10 and adjust the channel send and fader controls. Make sure the groups (mix bus masters) are NOT routed to the stereo master output. mix bus 9 and 10) should then be wired into the amplification feeds to the speaker systems. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MIDAS CONSOLES MIDAS SIENA Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIDAS CONSOLES MIDAS SIENA will begin.