Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE DA 72. We hope that this MIELE DA 72 user guide will be useful to you.
Lastmanuals help download the user guide MIELE DA 72.
Detailed instructions for use are in the User's Guide.
[. . . ] Read these instructions carefully before installing or using the Ventilation System. Use the appliance only for its intended purpose.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
~ a) Use this appliance only in the
manner intended by the manufacturer. appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. [. . . ] A time of 20 hours should also be programmed if the kitchen is only used occasionally. Otherwise grease which has accumulated over a long period of time will harden on the filters making cleaning more difficult. Reprogramming the grease filter timer ^ Press the joystick to the left to turn the fan off.
^ Use the joystick to select the desired time. Press it to the left for a shorter operating time, to the right for a longer operating time.
^ Store the selection by pressing the grease filter button. All indicators will go out.
^ Press the Delayed Shut Down and the grease filter buttons at the same time. The grease filter indicator and one of the fan power indicators will flash. The fan power indicators show the programmed time: 1st indicator from the left = 20 hours 2nd indicator from the left = 30 hours 3rd indicator from the left = 40 hours 4th indicator from the left = 50 hours
If the procedure is not stored within 4 minutes of programming the hood will automatically default to the "old" data.
14
Operation
Reprogramming the charcoal filter timer The active charcoal filters can only be used in recirculation mode and cannot be used to exhaust fumes. The charcoal filter timer is not preset. Before using the hood in recirculation mode, the charcoal filter timer must be programmed. ^ Press the joystick to the left to turn the fan off. ^ Use the joystick to select the desired time. ^ After cleaning, the filters can be placed on a towel to air dry. ^ While the filters are removed, clean any dirt or grease from the filter casing to prevent the risk of fire.
The grease filters should be cleaned every 3 - 4 weeks, when the grease filter indicator lights, or when they are visibly dirty, whichever comes first.
, A dirty filter is a fire hazard.
17
Cleaning and care
Inserting the grease filters When putting the grease filters back make sure that the locking clips are visibly facing the cooking surface.
If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing. ^ After returning the grease filters, press and hold the grease filter button for 3 seconds to reset the timer. ^ If the grease filters are cleaned before the grease filter timer has reached its maximum, press the grease filter button for 6 seconds to reset the counter to zero.
18
Cleaning and care
Active charcoal filter
DA 2280 uses 2 active charcoal filters DA 2210 uses 4 active charcoal filters In recirculation mode active charcoal filters must be used in addition to the grease filters. The active charcoal filters will be replaced in the canopy above the grease filters. Replacement active charcoal filters can be ordered from Miele. ^ Remove the grease filters to access the charcoal filters. See "Cleaning and Care - Grease filters".
^ Insert the charcoal filters. Before using: ^ Program the charcoal filter timer, see "Operation / Reprogramming the charcoal filter timer".
Replace the active charcoal filters when the charcoal filter indicator lights, at least every 6 months or when they no longer absorb odors efficiently. ^ After replacing the charcoal filters, press and hold the charcoal filter button for about 3 seconds to reset the charcoal filter timer. ^ If the charcoal filters are replaced before the timer has reached its maximum, the charcoal filter button should be pressed for 6 seconds to reset the counter to zero.
19
Cleaning and care
Changing the light bulb , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions".
When in use halogen bulbs become extremely hot, and they can burn your hands. [. . . ] If flat ducting is used, the cross section must not be smaller than the cross section of the ventilation exhaust. The ducting should be as short and straight as possible. The exhaust duct must not be bent or compressed. Make sure all connections are secure. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 72
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 72 will begin.