User manual MIELE F1471VI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE F1471VI. We hope that this MIELE F1471VI user guide will be useful to you.

Lastmanuals help download the user guide MIELE F1471VI.


Mode d'emploi MIELE F1471VI
Download

You may also download the following manuals related to this product:

   MIELE F1471VI INSTALLATION MANUAL (3317 ko)

Manual abstract: user guide MIELE F1471VI

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions Freezer with Ice/Water Dispenser F 1471 Vi To prevent accidents and appliance damage read these instructions before installation or use. en - US, CA M. -Nr. 07 155 770 Contents IMPORTANT SAFETY INSTRUCTIONS. 9 Control panel for Ice/Water Dispenser . 12 Turning off for longer periods of time . [. . . ] When you are in the Custom settings mode the door alarm is turned off automatically. Once the door is closed it is reactivated. To purchase a bypass cartridge, contact Miele. After installing a new water filter discard the first 24 hours of ice production. 39 Filter Performance Data Sheet State of California Department of Public Health Water Treatment Device Certificate Number 06 - 1775 Date Issued: March 10, 2006 Date Revised: April 3, 2008 Trademark/Model Designation 9000 077095 Miele 07134220 Manufacturer: Cuno, Incorporated The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants: Microbiological Contaminants and Turbidity Cysts Turbidity Organic Contaminants None Inorganic/Radiological Contaminants None Replacement Elements 9000 077104 07134220 Rated Service Capacity: 740 gals Rated Service Flow: 0. 75 gpm Conditions of Certification: Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. 40 Filter Performance Data Sheet Performance Data Sheet For Filter Model 07134220 Using Replacement Cartridge 07134220 This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. System tested and certified by NSF International in Model 07134220 against NSF/ANSI Standard 53 for the reduction of Cysts and Turbidity and against Standard 42 for the reduction of Chlorine Taste and Odor; Nominal Particulate Class I. To a capacity of 739. 68 gallons (2800 liters). Substance Average Influent Challenge Product Average Maximum Permissible Influent Concentration Water % Product Water Concentration mg/L Concentration Reduction Concentration 166500 Minimum 50, 000/L 1 99. 99 99. 95 10. 7 11 + 1 NTU 0. 31 97. 09 0. 5 NTU Max. % Effluent Reduction 1 0. 49 99. 99 95. 42 NSF Test 516458-05 516456-05 Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Cysts* Turbidity Particulate Class I Particle size: > 0. 5 to < 1 um Chlorine taste and odor 5700000 1. 9 At least 10, 000 particles/ml 2. 0 mg/L ± 10% 30583 0. 05 99. 52 97. 3 > 85% > 50% 69000 0. 06 98. 9 96. 84 511079-03 511081-03 * Based on the use of Cryptosporium parvum oocysts Application Guidelines/Water Supply Parameters Water pressure 30- 120 psi (207 - 827 kPa) Water temperature* 33°F - 100°F (0. 6°C - 38°C) Service flow 0. 75 gpm (2. 83 lpm) IMPORTANT: Must be installed and operated in accordance with application guidelines. Flush new cartridge for 3 minutes. CAUTION: To avoid property damage due to water leakage, you MUST read and follow these operating instructions before installation and use of this product. WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. NSF is a registered trademark of NSF International. CUNO is a trademark of 3M Company used under license. All rights reserved. For estimated costs of replacement elements please visit your local appliance dealer or parts distributor. 41 Frequently asked questions With the aid of the following guide minor problems can be corrected without a service call. Repairs should only be carried out by a qualified and trained person in strict accordance with local and national safety regulations. Unauthorized repairs could cause personal injury or machine damage and may void the warranty. Problems with temperature Issue The freezer does not get cold. Possible fault Solution The machine is not turned Check whether the appliance is on. Check that the plug is correctly inserted in the power outlet. See "Selecting the correct temperature". The temperature is Select a warmer too low. temperature. The SuperCool function is SuperCool automatically shuts still on. A large amount of food is being frozen at the same time. The room temperature is lower than the ambient temperature for which the appliance is designed. Check that the door has been closed properly. This makes the compressor run longer, causing the temperature to fall automatically. Operating the appliance in a room that is too cold will cause the cooling system to switch off for too long, causing the freezer section to become too warm. 42 Frequently asked questions General problems Issue Possible fault Solution Water is flowing out of Close the shut-off valve immediately. [. . . ] Be sure your wireless system meets the following requirements ­ A wireless router that supports an IEEE 802. 11b protocol ­ Windows XP® or newer operating system, Mac® OS X 10. 3 or higher ­ Cable or DSL modem ­ Microsoft® Internet Explorer 6 or higher, Safari 2. 0 or higher, Firefox 1. 5 or higher * Please note that each wireless router manufacturer supplies their own device drivers and setup programs. Due to the differences in manufacturers, exact router setup instructions are not included in this manual. Wording and instructions may vary. 80 RemoteVision Accessing the RemoteVision control panel ^ Tap the X button until ; appears in the display. ^ Touch the access button "p" to confirm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE F1471VI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE F1471VI will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag