User manual MIELE KM 326LP GAS COOKTOP OPERATING MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE KM 326LP GAS COOKTOP. We hope that this MIELE KM 326LP GAS COOKTOP user guide will be useful to you.
Lastmanuals help download the user guide MIELE KM 326LP GAS COOKTOP.
Manual abstract: user guide MIELE KM 326LP GAS COOKTOPOPERATING MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Operating instructions Gas hob KM 326G Conversion kit AH 102 C4U
Instructions pour l'utilisation du dessus de cuisinière au gas KM 326G Kit de conversion AH 102 C4U
a r t . 2 0 / T 9 1 7 0 1 B
english
USA
CDN
page page page page page page
1 - 27 1 - 17 18 - 27 28 - 55 28 - 45 46 - 55
operating instructions gashob KM 326G converting instructions converting kit AH 102 C4U français
CDN
Instructions pour l'utilisation du dessus de cuisinière au gas KM 326G Mode d'emploi du kit de conversion AH 102 C4U
Warning
If the information in this manual is not followed exactly, a fire or explosion may result causing damage to property, personal injury or death. * Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. * What to do if you smell gas Do not try to light any appliance. [. . . ] natural gas propane gas 4 water column 10 water column appliance with conversion kit number AH102 C4U. supply pressure: 1/2 psi 11 water column Natural gas Max. supply pressure: 1/2 psi 5 water column
13
For Canada only The gas connection must be made in accordance with the local codes, or in absence of local codes, with the current CAN/CA B 149. 1 and . 2 Inst. Gas pressures for Canada Manifold pressure: natural gas 4 water column liquid propane gas 10 water column Nominal rating natural gas 4 1)
Burner high setting kW high-speed burner 2. 7 Btu/hr 9200 12000 14000 low setting kW Btu/hr 0. 35 1200 0. 45 1500 0. 17 580
b. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3. 5 kPa). Warning The base of the hob will become hot. The gas connection used must comply with the relevant national and local regulations. Important When the gas hob has been installed, it is essential to check the main cable is not in contact with hot parts of the appliance, otherwise temperature damage to the cable could occur.
super high-speed burner 3. 4 2-zone wok burner 4. 0
Nominal rating LP gas 10 with conversion kit 1)
Burner high setting kW high-speed burner super high-speed burner 2-zone wok burner 2. 0 2. 7 Btu/hr 7000 9200 low setting kW Btu/hr 0. 40 1300 0. 50 2000 0. 18 600
1)
Important
This appliance with the orifices as delivered for natural gas or LP gas by the manufacturer is suitable for use till 2000 feet. By installation above 2000 feet contact your distributor or Miele USA/Canada and ask for a replacement set with orifices suitable for your altitude. Change the orifices as written in the instructions of the manual.
3. 3 11200
Important a. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of this system at test pressures in excess of 1/2 psi (3. 5 kPa).
14
Building-in dimensions
35 7/16" (900 mm)
20 3/16" (515 mm)
3" (75 mm)
min. 1 3/4" (45 mm)
19 5/16" (490 mm)
min. 3" (75 mm)
33 7/8" (860 mm)
Prepare a cut-out in the worktop according to the dimensions given in the diagram above.
There may be a wall at the rear and a wall or tall units at one side. On the other side, however, no unit or divider may stand higher than the hob.
15
Clearance above and around the appliance
min 33 1/4" (845 mm)
min 33 1/14" (845 mm) min 18" (460 mm)
min 10" (254 mm)
min 10" (254 mm)
not allowed
For safety reasons, ensure that the following minimum clearences are provided: between adjacent combustible construction 4" (100 mm). between appliance and rear wall 1 3/8" (30 mm). between appliance and the overhead combustible construction 33 1/4" (845 mm). between appliance and front edge of worktop 2 9/16" (65 mm). depth of overhead cabinets must not exceed 13" (330 mm). between combustible constructions and the extended cooking surface 18" (460 mm). 10" (254 mm)
not advisable
recommended
Building-in
1. Ensure that there is sufficient space allowed at the sides and at the rear. Attach the sealing strip to the underside of the hob and the aeration profile. [. . . ] Use a small screwdriver and replace each screw individually. Connect the wires to the ignition plugs. Put the high-speed and super high-speed burner base plates and burner rings back. Fasten the high-speed and super high-speed venturis using a 20 mm wrench.
Installing appliance
1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE KM 326LP GAS COOKTOP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE KM 326LP GAS COOKTOP will begin.