[. . . ] Operating Instructions Vented Dryer T 1312 T 1313
To prevent accidents and machine damage, read these instructions before Installation or use.
UV
M. -Nr. 06 610 660
Contents
IMPORTANT SAFETY INSTRUCTIONS . Turn on the dryer and load the laundry . 12 Adding or removing laundry during a program . [. . . ] The bulb cover is located along the upper rim of the drum opening.
, Make sure the bulb cover is
securely closed to prevent a short circuit or penetrating moisture. ^ Restore power.
^ Slide a screwdriver with a wide head underneath the side edge of the bulb cover and twist (see illustration). ^ Flip down the bulb cover.
16
Frequently asked questions
What if the dryer will not run?
Possible fault Fix
The "Start/Stop T" button was not pressed. The circuit breaker tripped or the dryer is unplugged. How do I prevent static cling?
Make sure the dryer is on. Press the "Start/ Stop T" button to begin the drying program. Make sure the dryer is plugged in or reset the circuit breaker. Close the door properly.
Add fabric softener to laundry when washing or select the "Less Dry" setting on the dryer. What if the drum light does not come on?
Possible fault Fix
The bulb may be bad or burned out.
See "Changing the light bulb. "
What if the "Child Lock" indicator flashes after turning the dryer on and a program cannot be started?
Possible fault Fix
The child lock is activated.
Deactivate the child lock. See "Child Lock. "
What if the program stops, the "Anti-crease / End" indicator lights and the buzzer sounds?
Possible fault Fix
The drum is empty.
Load laundry into the dryer. The dryer will not operate when the drum is empty. Single items should be dried with "Sturdy" or a timed program and dry items in the "Fluff" program.
What if the "Filter/Vent" fault indicator is lit?
Possible fault Fix
The lint filter is clogged. The exhaust hose or the connection is clogged with lint. The air supply in the room is insufficient.
Clean the lint filters. Remove lint and check the exhaust system for blockages. Open a window or door to increase airflow.
17
Frequently asked questions
What if the "Filter/Vent" indicator lights after cleaning the exhaust system?
Possible fault Fix
The dryer is not operating efficiently because the duct hose is too long.
Check the exhaust length and diameter (see "How to calculate the effective duct length"). A long exhaust hose will increase program times and energy consumption. If the exhaust hose cannot be shortened, the indicator can be turned off by a service technician.
What if the program runs too long or stops?
Possible fault Fix
The airflow is insufficient in the area of the dryer. The lint filters are clogged.
Open a window or door to increase airflow. Clean the lint filters (see "Dryer care").
The laundry was not spun sufficiently in Select a higher spin speed in the wash the washer. Metal zippers interfere with the dryer's moisture sensors. Select a timed program to avoid overdrying.
An airflow gap of 3/8" (10 mm) must be This gap must not be blocked by a provided between the machine and the toekick or thick piled carpets for sufficient airflow. [. . . ] Necessary materials: a wall or window duct an exhaust hose made of approved non-flammable material Window connection
1 Window connection (installed in a plexiglass pane) 2 Connector for the flexible exhaust hose Wall connection with rigid pipe
^ If the duct length is more than 33 ft (10 m), remove the ring adapter, 1, from the connector, 2. If the duct length is less than 33 ft (10 m), leave the ring adapter in to improve time and energy efficiency. ^ Install the connector, 2, with the exhaust hose or pipe, 3, to the dryer.
1 Wall pipe 2 Connector 3 Rigid pipe
30
Installation
Direct wall connection
Necessary materials: a wall pipe flexible foam gasket Dryer top view Dryer side view
1 Wall pipe 2 Flexible foam gasket
1 Wall pipe 2 Flexible foam gasket
^ Insert the ring adapter, 1, into the wall pipe. Connect the flexible foam gasket, 3, to the wall pipe connector, 2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE T1312
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.