User manual MINOLTA CA-100PLUS BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MINOLTA CA-100PLUS. We hope that this MINOLTA CA-100PLUS user guide will be useful to you.

Lastmanuals help download the user guide MINOLTA CA-100PLUS.


Mode d'emploi MINOLTA CA-100PLUS
Download
Manual abstract: user guide MINOLTA CA-100PLUSBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] CRT COLOR ANALYZER CRT CRT COLOR ANALYZER CA-100Plus Application Chromaticity Adjustment, Inspection White-balance Adjustment, Inspection Cut-off Adjustment, Inspection Select the probe among the following four types. Measuring Probe (Cable length: 2 m) Measuring Probe (Cable length: 5 m) High luminance Measuring Probe (Cable length: 2 m) High luminance Measuring Probe (Cable length: 5 m) Up to five probes can be connected to a single main body. [. . . ] CA-100Plus is for those who already have CA-100 and who want to maintain data compatibility, or for those who have established a communication environment including CA-100 and who intend to use the new analyzer. Display Unit POWER ON CA-100Plus x y OFF x y Lv CH01 EXT Fa P1 [EXT D-1. 50] PQRS TUV WXYZ v 7 GHI 8 JKL 9 MNO MENU LOCK ALPHA - SPACE CAL 4 White 5 ABC 6 DEF 0-CAL MODE REMOTE HOLD MR MEMORY CH 1 Red 2 Green 3 Blue Matrix Calibration User's own matrix correction factor is set to the memory channels by measuring three monochrome colors (R, G, B and W) of known values and setting the obtained calibration values (xyLv) and emission characteristic to the instrument. Once this factor is set, the measured values will be displayed after correction by this factor and output each time measurement is taken. Performing matrix calibration enables high-accuracy measurements of displays that provide colors through additive color mixing of three monochrome colors (R, G and B). Since the matrix correction factor obtained from Minolta's calibration standard has been set, measured values calculated based on this factor will be acquired when this instrument is used for the first time since shipment from the factory. 0 . ENTER Pattern Signal Writing gain and cutoff level Data from CA Command to CA-100Plus Pattern Generator Software made with SDK PC Software for Color Analyzer l l CA-SDK (Standard accessory) Sample software (Standard) Standard accessory SDK helps create software easily according to needs. Sample software is bundled; you can start data collection easily. Cal CA-100Plus is corrected in the matrix calibration method using Konica Minolta's spectroradiometer CS-1000A. Color The measurement data of CA-100Plus is acquired into the PC. Drift tests, repeatability test and so on can be performed easyly. The acquired data can be read with EXCEL® or other spreadsheet software. Contrast Multi-point measurement (5, 9, or 25 points) is made for white uniformity measurement. Required system OS Windows® 98, 2000, ME, XP (x64 Edition not supported) PC: COM Port support Display sample Windows® and Excel® are a trademark of Microsoft Corporation in the USA and other countries. System Diagram PC (Commercially available) PC-AT compatible Multi-Probe 4-Probe Expansion Board CA-B04 (Optional) Dimensions (Units : mm) 340 60 45 60 CA-100Plus PC Software for Color Analyzer CA-SDK (Standard) 44 70 110 127 AC Power Cord (Standard) Specifications Receptor Display range Luminance Luminance Chromaticity Measurement range Accuracy (for white)*1 Repeatability *1 Measurement range Accuracy *1 (temperature : 23°C±2°C, relative humidity : (40±10)%) Repeatability *1 CA-100Plus(High luminance Measuring Probe 2 m or 5 m) CA-100Plus(Measuring Probe 2 m or 5 m) Detector : Silicon photo cell 2 0. 01 to 2000 cd/m2 0. 01 to 1000 cd/m Displayed in 4 or 3-digit value (Can be chosen) 0. 05 to 1000 cd/m2 0. 05 to 2000 cd/m2 ±2 %±1 digit of reading (temperature : 23°C±2°C, relative humidity : (40±10)%) 0. 05 to 1000 cd/m2 0. 2 %+1 digit (2 ) 0. 05 to 2000 cd/m2 0. 2 %+1 digit (2 ) 0. 05 to 1000 cd/m2 0. 05 to 0. 19 cd/m2 ±0. 006 (for white) 0. 20 to 0. 49 cd/m2 ±0. 004 (for white) 0. 50 to 1000 cd/m2 ±0. 003 (for white) 40. 00 cd/m2 ±0. 002 (for white), ±0. 004 (for monochrome)*2 0. 05 to 0. 19 cd/m2 0. 006 (2 ) 0. 20 to 0. 49 cd/m2 0. 002 (2 ) 0. 50 to 1000 cd/m2 0. 001 (2 ) 0. 05 to 0. 99 cd/m2 5 measurements/sec. (4. 5 measurements / sec. )*4 1. 00 to 1000 cd/m2 20 measurements/sec. (17 measurements / sec. )*4 0. 05 to 2000 cd/m2 0. 05 to 0. 09 cd/m2 ±0. 008 (for white) 0. 10 to 0. 39 cd/m2 ±0. 006 (for white) 0. 40 to 0. 99 cd/m2 ±0. 004 (for white) 1. 00 to 2000 cd/m2 ±0. 003 (for white) 40. 00 cd/m2 ±0. 002 (for white), ±0. 004 (for monochrome)*2 0. 05 to 0. 09 cd/m2 0. 009 (2 ) 2 0. 10 to 0. 39 cd/m 0. 006 (2 ) 0. 40 to 0. 99 cd/m2 0. 002 (2 ) 1. 00 to 2000 cd/m2 0. 001 (2 ) 0. 05 to 1. 99 cd/m2 5 measurements/sec. (4. 5 measurements / sec. )*4 2. 00 to 2000 cd/m2 20 measurements/sec. [. . . ] Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Certificate No : YKA 0937154 Registration Date : March 3, 1995 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 ©2003 KONICA MINOLTA SENSING, INC. 9242-4885-12 AGMEPK 9 17 Measuring Probe Holder CA-A11 (Standard) Measuring Probe (2 m) CA-P02 Measuring Probe (5 m) CA-P05 High luminance Measuring Probe (2 m) CA-PH02 High luminance Measuring Probe (5 m) CA-PH05 Printed in Japan 47. 4 2m/5m Measuring Probe (2 m) CA-P02 Measuring Probe (5 m) CA-P05 High luminance Measuring Probe (2 m) CA-PH02 High luminance Measuring Probe (5 m) CA-PH05 (Optional) 30. 2 ISO 5 mm screw (depth : 6 mm) 216 142 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CA-100PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CA-100PLUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag