Detailed instructions for use are in the User's Guide.
[. . . ] 2D Color Analyzer
CA-2000
CA-2000S CA-2000W CA-2000T CA-2000SW CA-2000ST CA-2000WT CA-2000A
(with standard lens) (with wide lens) (with telephoto lens) (with standard & wide lenses) (with standard & telephoto lenses) (with wide & telephoto lenses) (with all lenses)
Easy evaluation of displays using high-resolution data !!
2D Color Analyzer for quick, accurate measurement of luminance and chromaticity distribution
2D Color Analyzer CA-2000 for quick, accurate measurement of luminance and chromaticity distribution !
The 2D Color Analyzer CA-2000 incorporates XYZ filters and a high-resolution CCD to offer sensitivity closely matching that of the human eye. This allows accurate 2D measurement of the luminance and chromaticity distribution of FPDs, projectors, and backlights with high-resolution data. User-friendly, included software enables PC control of the CA-2000 for quick and efficient measurement, data analysis, and evaluation with easy operation. [. . . ] Accurate m e a s u r e m e n t o f l u m i n a n c e a n d c h r o m a t i c i t y distributioncanbestartedimmediatelyafterpurchase.
I
ndividual lens calibration using multiple focal points
Hood Cap CA-A71
Lens Hood (For standard/telephoto lens) CA-A68
Pan Head CS-A4
AC Adapter AC-A22
e
Telephoto Lens CA-A74 Low-magnification Macro1 High-magnification Macro2 Lens Hood (For macro measurement) CA-A70
Tripod CS-A3
Soft Case CA-A60
sign eight de & lightw anywhere !t C o m pa c a s y s e t u p ables e en
Standard
Components other than those shown in the areas shaded are common for all packages.
* Each lens comes with a lens cap, mount cap, and calibration data DVD.
q 2D Color Analyzer (with standard lens) w 2D Color Analyzer (with wide lens) e 2D Color Analyzer (with telephoto lens) Combination of q and w (with standard and wide lenses) Combination of q and e (with standard and telephoto lenses) Combination of w and e (with wide and telephoto lenses) Combination of q, w and e (with all lenses)
CA-2000S CA-2000W CA-2000T CA-2000SW CA-2000ST CA-2000WT CA-2000A
Model with standard lens
Lens hood for standard/ telephoto lenses
Si z
e
Measurable object size with typical measurement distances
Standard lens Wide lens Telephoto lens
(Width/height of measurement square)
Distance
Low magnification macro ring
High magnification macro ring
Wide
Model with wide lens
(mm) 200 250 300 500 900 1000 1500 2000 3000 4000 5000
Measurement size (mm)
Measurable display size Measurable display size Measurable display size Measurable display size Measurable display size Measurement Measurement Measurement Measurement (inches) (inches) (inches) (inches) (inches) size size size size (mm) (mm) (mm) (mm) 16 9 43 43 16 9 43 16 9 43 16 9 43
16
Wide lens
Lens hood for wide lens
Telephoto
Model with telephotoTelephoto lens
98 121 212 393 439 665 892 1345 1798 2252
4. 4 5. 5 9. 6 18 20 30 40 61 81 102
4. 8 6 10. 4 19 22 33 44 66 89 111
145 190 235 416 779 869 1323 1776 2682 3589 4495
9 6. 5 8. 6 11 19 35 39 60 80 121 162 203
7. 1 9. 3 12 20 38 43 65 87 132 177 221
1. 2 57 116 130 203 275 420 566 711 5. 2 5. 9 9. 2 12 19 26 32 5. 7 6. 4 10 14 21 28 35 2. 5 2. 8
1. 3
Telephoto Macro 2 Macro 1
Macro rings
Dimensions
Lens hood for macro measurement Lens hood for standard/ telephoto lenses Main unit
(Unit: mm)
52. 8 113 47 <Reference position> M5, Depth: 6. 5 211. 3 60 60 Tripod Socket UNC 1/4, Depth: 6. 5 Hole for positioning pin Rubber foot diameter: 15 160 14 95. 2 125. 2 14
When standard lens and lens hood are attached
Reference Position
97
199 223. 5
9. 3
155
Telephoto lens
Main Specifications CA-2000
Model Lightreceptor Lens Measurementpoints(Resolution) Colorindicationmodes Displaymodes Measurementsizes (lengthpersideofsquare)(*1) CA-2000S CA-2000W CA-2000T CCDimagesensor(monochrome);2/3-inch;Effectivenumberofpixels:1, 000x1, 000pixels;EquippedwithXYZfilter(closelymatchesCIE1931colormatchingfunction)andNDfilter InterchangeableStandard, wide, andtelephotolenses;low-magnificationandhigh-magnificationmacrorings(forusewithtelephotolens) 980x980(Availabletoselect490x490or196x196byusingDataManagementSoftwareCA-S20w) XYZ, Lv xy, Lvu'v', T uv, Dominantwavelength, Excitationpurity, Lvcontrast Pseudocolor, RGBimage, Chromaticitydiagram, Spot, 3Dgraph, Histgram, Nonuniformityenhancement, Crosssection, Colordifference, Multi-screen
Standardlens Widelens Telephotolens Withlow-magnificationmacroring Withhigh-magnificationmacroring Approx. 98mmormore Approx. 145mmormore Approx. 115mmormore Approx. 27mm(Fixed) Approx. 57mm(Fixed) (dependingonthedistance) (dependingonthedistance) (dependingonthedistance) 98mm/250mmmmApprox. Measurablesizefortypicalmeasure- 210mm/500mmApprox. mentdistances(size/distance) 850mm/1, 000mmApprox. Measurementluminancerange 0. 1-100, 000cd/m2 0. 1-100, 000cd/m2 0. 5-100, 000cd/m2 0. 5-100, 000cd/m2 1-100, 000cd/m2 (includingNDfilteruse) Single:Approx. 5sec. ormore;4-timeintegration:Approx. 6sec. ormore;16-timeintegration:Approx. 10sec. ormore;64-timeintegration:Approx. 28sec. Measurementtime(*2) ormore;256-timeintegration:Approx. 98sec. ormore Luminance ±3% ±3% ±3% ±3% ±3% Chromaticity ±0. 005 ±0. 005 ±0. 005 ±0. 005 ±0. 005 Temperature/humiditydrift(withintheoperatingtemperature/humidityrange) Accuracy(*3) Luminance:±2%ofchangecomparedtoreferencetemperatureandrelativehumidityof23°Cand40% Chromaticity:±0. 004ofchangecomparedtoreferencetemperatureandrelativehumidityof23°Cand40% Luminance 0. 5% 0. 5% 0. 5% 0. 5% 0. 5% Repeatability(*4) Chromaticity 0. 001 0. 001 0. 001 0. 001 0. 001 Luminance(*6) ±2% ±2% ±2% ±2% ±2% ±0. 002 ±0. 002 ±0. 002 ±0. 002 ±0. 002 Inter-point error Chromaticity(*6) (*5) Luminance(*7) ±3% ±3% ±3% ±3% ±3% Chromaticity(*7) ±0. 003 ±0. 003 ±0. 003 ±0. 003 ±0. 003 Intervalmeasurement, Measurementsync(Synchronizationfrequencyselectable), Integrationfunction, Enhancednonuniformitydisplay, ConversionofenOtherfunctions hancednonuniformityimageintonumericalvalues(statisticalvalues, etc. ), Pixelbinningfunction Interface USB2. 0orhigher Operatingtemperatureandhumidityrange(*8) 10-30°C, Relativehumidity70%orless/Nocondensation Storagetemperatureandhumidityrange(*8) 0-30°C, Relativehumidity70%orless/Nocondensation, 30-35°C, Relativehumidity55%orless/Nocondensation 160(W)×164(H)×199(D)mm(Heightincludinghandle:211mm) 224(D)mm 219(D)mm 224(D)mm 230(D)mm Weight 3. 5kgapprox. (whenstandardlensandlenshoodareattached) Powersource ACadapter100-240V , 1. 2A, 50-60Hz LensHood CA-A68 CA-A69 CA-A68 CA-A70 CA-A71 CA-A75 CA-A71 HoodCap Standard CalibrationdataDVD Includedwitheachlens. accessories Other MountCoverCA-A61, ACAdapterAC-A22, ACcable, USBCableIF-A18, DataManagementSoftwareCA-S20w Optionalaccessories SoftCaseCA-A60, TripodCS-A3, PanHeadCS-A4, Calibrationcertificate Size
*1: Errorinangleofview:7% *2: Measurementtimediffersdependingonbrightnessofmeasurementobject, PCperformance, anddataprocessing contents. ThespecificationsabovewereobtainedunderKonicaMinolta'smeasurementconditionsshownbelow: PC'sCPU : Pentium4, 2. 8GHz Dataprocessing : Pseudocolordisplayofluminancedata Resolution : 490x490 Shutterspeed : Ymeasurement:1/64sec. , XZmeasurement:1/32sec. Forstandardlens:approx. 540MB Forwidelens:approx. 470MB Fortelephotolens:approx. 1. 3GB Alsotosavemeasurementdataonharddisk, additionalfreespaceisrequired. (approx. 11GBminimumfor1000measurementdatainresolutionof980x980) Displaycapableofatleast1280x1024dots/65, 536colors(Highcolor, 16bit). CD-ROMdrive(necessarytoinstallsoftware) DVD-ROMdrive(necessarytoinstallcalibrationdata)
(AcombinationdrivecapableofreadingbothCD-RandDVD-Rmediacanbeusedinplaceoftheabove2drives. )
USBport:USBver. 2. 0;TypeAconnector;Forconnectingmeasuringinstrument Excel®2003(Necessaryforcontinuousmeasurementsusingautomation)
·Windows®, Excel®isaregisteredtrademarkoratrademarkofMicrosoftCorporationintheUnitedStatesandother countries. ·Pentium®isaregisteredtrademarkoratrademarkofIntelCorporationintheUnitedStatesandothercountries. Thespecificationsanddrawingsgivenhereare subjecttochangewithoutpriornotice. [. . . ] If the instrument is left under the following high-temperature conditions for a long period of time, the displayed values may change as follows: Temperature: 30 C; Relative humidity:70 %; Period under these conditions: 720 hours (30 days) Accuracy: Luminance: 0. 4 %; Chromaticity: 0. 003 Inter-point error: Luminance: 0. 2 %; Chromaticity: 0. 0003 Temperature: 35 C; Relative humidity:55 %; Period under these conditions: 336 hours (14 days) Accuracy: Luminance: 1 %; Chromaticity: 0. 006 Inter-point error: Luminance: 0. 5 %; Chromaticity: 0. 001 These differences in display values are due to the instrument materials and/or components being affected by the temperature and humidity conditions of long-term use or storage. In particular, optical filters are easily affected by temperature or humidity. Although measures have been taken to improve resistance to temperature/humidity changes, the accumulated effect of long-term use or storage may affect the displayed values.
Printed in Japan
AHDAPX(2) [. . . ]