User manual MINOLTA CM-3700D BROCHURE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MINOLTA CM-3700D. We hope that this MINOLTA CM-3700D user guide will be useful to you.
Lastmanuals help download the user guide MINOLTA CM-3700D.
Manual abstract: user guide MINOLTA CM-3700DBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] CM-3700d
SpectraMagic NX (Optional)
TM
A High-Accuracy Benchtop Spectrophotometer With Konica Minolta's Optical Technology for High Performance and Computer Control for Easy Operation
High-speed, high-accuracy measurements
Measurements at wavelengths from 360 to 740nm at 10nm pitch are taken in approximately 0. 6 seconds. Konica Minolta's optical technology ensures high absolute- value accuracy and repeatability, and extremely strict quality control provides higher inter-instrument agreement and reliability. [. . . ] The amount of UV included in the illumination can be controlled in 1000 steps for measurements of fluorescent materials.
!0Transmittance measurements
The spectral transmittance of liquids or of specimens in sheet or plate form can be measured using di:0°, de:0° (diffuse illumination/0° viewing angle) geometry.
o
!0
SpectraMagic NX
TM
(optional)
Supports Windows®2000/XP/Vista
SpectraMagic NX enables you to perform comprehensive color inspection and analysis of incoming raw materials, in process production, and outbound color critical goods and materials in virtually any industry. With SpectraMagic NX you can insert digital images with measured data. Measure samples in any of 8 universally accepted color spaces. Select from 15 illuminants, and up to 40 indices to determine specific color and appearance properties, such as strength, brightness, haze, yellowness, opacity and strength. You can even configure up to 3 customized color equations. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagic NX comes with predefined templates using skin technology, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's well known and respected "Precise Color Communication". Step by step navigation help.
TM TM TM
Windows® is a trademark of Microsoft Corporation in the USA and other countries.
System Diagram
Cell CM-A97 (2mm) Cell CM-A98 (10mm) Cell CM-A99 (20mm) Plastic Cell Plastic Cell Plastic Cell CM-A130 CM-A131 CM-A132 (2mm: set for 100) (10mm: set for 100) (20mm: set for 100) RS-232C Cable CM-A52 (9-pin, 2m) Personal computer
RS-232C Cables CM-A55 (9-pin, 5m)
Transmittance Specimen Holder CM-A96 Target Mask CM-A91 (3x5mm)
Transmittance Zero Calibration Plate CM-A100
SpectraMagic NX CM-S100w
TM
Target Mask CM-A92 ( 8mm)
AC Adapter Spectrophotometer CM-3700d
Target Mask CM-A93 ( 25. 4mm) White Calibration Plate CM-A90 Accessory Case CM-A66
(standard accessory)
(with floppy disk containing calibration data) Zero Calibration Box
CM-A94
Color Tiles
Standard accessories
Optional accessories
Optional Accessories
Transmittance Specimen Holder CM-A96
Holds specimens in place for transmittance measurements. Maximum specimen thickness: 22. 5mm
Glass Cell CM-A97/CM-A98/CM-A99
Transmittance Zero Calibration Plate CM-A100
For performing zero calibration for transmittance measurements.
Color Tiles
14 color tiles are available: White, Pale grey, Middle grey, Difference grey, Deep grey, Deep pink, Red, Orange, Bright yellow, Green, Difference green, Cyan, Deep blue, Black. Original materials of these tiles are supplied by BCRA.
Hold liquid specimens for transmittance measurements. Optical path lengths: 2mm (CM-A97), 10mm (CM-A98), and 20mm (CM-A99)
Plastic Cells CM-A130(2mm), CM-A131(10mm), CM-A132(20mm) are also available.
Reflectance: di:8 , de:8 (diffuse illumination/8 viewing angle); SCI (specular component included )/SCE(specular component excluded) switchable; meets CIE, ISO, ASTM, and DIN standards. Transmittance: di:0 , de:0 (diffuse illumination/0 viewing angle) Detector Silicon photodiode array with flat holographic grating Wavelength range 360 to 740nm Wavelength pitch 10nm Half bandwidth Approx. 14nm average Photometric range 0 to 200%; Resolution: 0. 001% Light source Pulsed xenon arc lamp Measurement time 0. 6 to 0. 8 sec. [. . . ] Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
©2003 KONICA MINOLTA SENSING, INC.
9242-4851-31
AILLPK 18
Printed in Japan [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CM-3700D Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CM-3700D will begin.