User manual MINOLTA CM-H2 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MINOLTA CM-H2. We hope that this MINOLTA CM-H2 user guide will be useful to you.

Lastmanuals help download the user guide MINOLTA CM-H2.


Mode d'emploi MINOLTA CM-H2
Download
Manual abstract: user guide MINOLTA CM-H2BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] This improves working efficiency and provides stable measured data since the measurement area does not shift when the mode is switched. And also Relativity Gloss Value can be displayed by using Numerical Gloss Control. Light source for specular component Light source for SCI Relativity Gloss Value The LCD specifications are subject to change without prior notice. Powerful partnership between TM CM-2500d and SpectraMagic NX Color Data Software SpectraMagic NX TM (Optional) · SCI is a method in which measurements are taken with the specular reflection included. For this reason, it minimizes influences of the surface condition of a sample, and is especially suitable for color quality control and Computer Color Matching. · SCE is a method in which measurements are taken excluding the specular reflection. [. . . ] This type of measurement provides results similar to those observed visually. Supports Windows®2000/XP Expanded LCD display (64 x 240 dots) Displays large quantities of information (simultaneous display of SCI and SCE data etc. ) High-accuracy sensor For plastics, paints, resins and consumer products High reliability and long life. Maintenance-free design. The number of moving parts in the instrument is minimized through the introduction of numerical control technology. The CM-2500d can be used with confidence, since it has been developed, manufactured and calibrated to meet ISO 9001 requirements. Measures at 10nm intervals for the full wavelength range. Excellent repeatability Illuminated viewfinder Allows measurement in any position. Compact, lightweight, with an easy-to-operate navigation wheel and large LCD display. The battery-powered small, light body allows the instrument to be placed in any position at the sample surface. The CM-2500d's large LCD display and its reverse display function provide easy reading, irrespective of which hand it is held in. Using your finger, the navigation wheel allows simple, user friendly operation. SpectraMagic NX conforms to FDA 21 CFR Part 11 assuring integrity and reliability of data records. TM TM TM TM · Windows® is a trademark of Microsoft Corporation in the USA and other countries. In various applications For pharmaceuticals, cosmetics, printing, building materials, textiles, food etc. Specifications Illumination/ d/8 (diffuse illumination, 8-degree viewing ), equipped with simultaneous viewing system measurement of SCI (specular component included)/SCE(specular component excluded) Conforms to CIE No. 15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7 and JIS Z8722 Condition C standard. Sphere Size ø52mm Light-receiving element Silicon photodiode array (dual 40 elements) Spectral separation device Diffraction grating Wavelength range 360nm to 740nm Wavelength pitch 10nm Half bandwidth Approx. 10nm Reflectance range 0 to 175%, resolution: 0. 01% Light source 2 pulsed xenon lamps Measurement time Approx. 2 seconds for fluorescent measurement) Minimum interval 3 seconds for SCI/SCE (4 seconds for fluorescent measurement) between measurements Battery perfomance Alkaline manganese:approx. 1000 measurements Measurement/ MAV: ø8mm/ø11mm illumination area Repeatability Spectral Reflectance:Standard deviation within 0. 1% (360 to 380nm within 0. 2%) Colorimetric Value : Standard deviation within E*ab 0. 04(Measurement conditions:White calibration plate measured 30 times at 10-second intervals after white calibration was performed) Inter instrument within E*ab 0. 2 (MAV/SCI) Average for 12BCRA Series II color agreement tiles compared to values measured with master body. Measurement Single measurement/automatic averaging of multiple measurements mode (auto mode: 3, 5, 8 times/manual mode) Interface RS-232C standard Observer 2/10 degrees (CIE 1931/2°, CIE 1964/10°) Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result Color space/ L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, colorimetric data XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE/Ganz), CIE00 Data memory 1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the " defined in COND. " mode. * Total of the sample data for the COND and TASK modes and color difference target data Tolerance Display Tolerance for color difference (both box and eliptical tolerances can be set) Power source 4 AA-size battery or AC adapter Size (WxHxD) 69 x 96 x 193mm Weight Approx. [. . . ] Measurement Single measurement/automatic averaging of multiple measurements mode (auto mode: 3, 5, 8 times/manual mode) Interface RS-232C standard Observer 2/10 degrees (CIE 1931/2°, CIE 1964/10°) Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result Color space/ L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, colorimetric data XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE/Ganz), CIE00 Data memory 1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the " defined in COND. " mode. * Total of the sample data for the COND and TASK modes and color difference target data Tolerance Display Tolerance for color difference (both box and eliptical tolerances can be set) Power source 4 AA-size battery or AC adapter Size (WxHxD) 69 x 96 x 193mm Weight Approx. 670g (without batteries) Operating temperature/ 5 to 40°C, relative humidity 80% or less (at 35°C) with no humidity range (*1) condensation Storage temperature/ 0 to 45°C, relative humidity 80% or less (at 35°C) with no humidity range condensation Standard White calibration plate, Target mask ø8mm, RS-232C cable, accessories AC adapter, AA-size battery (x4) Optional Hard case, Dust cover set, Dust cover, Accessories SpectraMagic NX(software), Zero calibration box TM System Diagram Standard Accessories Optional Accessories Target mask ø8mm CM-A146 AA-size AC Adapter AC-A17 battery (x4) AC Adapter AC-A23 (for Korea) Personal Computer (commercially available) RS232C cable IF-A16 CM-2500d White calibration plate CM-A145 SpectraMagic NX CM-S100w TM Zero calibration box CM-A32 Hard case CM-A148 Dust cover set Vinyl cover Dust cover CM-A149 CM-A152 Dimensions (Units:mm) CM-2500d 69 193 *1 Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation CM-3700d CM-3600d Color control network by spectrophotometer High inter-instrument agreement between the portable CM-2500d spectrophotometer and the desktop CM-3000 series make it easy to build a total color control network. CM-2500d R&D Quality Production R&D R&D CM-2500d Company A Quality control Production Quality Production Company B In-house color control Color control among companies * The specifications and drawings given here are subject to change without prior notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CM-H2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CM-H2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag