User manual MINOLTA CM3610D BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MINOLTA CM3610D. We hope that this MINOLTA CM3610D user guide will be useful to you.

Lastmanuals help download the user guide MINOLTA CM3610D.


Mode d'emploi MINOLTA CM3610D
Download
Manual abstract: user guide MINOLTA CM3610DBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Built for Precision, Priced for Economy Outstanding Performance through Innovative Technology CM-3600d Horizontal Spectrophotometer Highly accurate, reliable and rugged Versatile instrument for most colorimetric applications Simplified operation. CM-3610d Vertical Spectrophotometer for best application support Speeds up textile and paper measurements Ideal for non contact measurements such as powders, pigments Quick sample handling and observation CM-3600d and CM-3610d Spectrophotometer: Highest Quality in Color Measurement in the Laboratory and for Production Enhanced Performance Technology Konica Minolta Innovative Optical System The CM-3600d and CM-3610d are equipped with Konica Minolta Innovative Optical System technology. [. . . ] SCI SCE specular component included specular component excluded Versatility Full wavelength range 360-740nm with 10nm pitch Large (6") sphere; d/8° geometry Reflectance and transmittance sample measurements Changeable measurement areas (ø4mm, ø8mm, or ø25. 4mm) View finder design for easy sample viewing Compact and lightweight Transmittance Measurement-The CM-3600d employs the d/0° geometry (diffused lighting, 0° viewing), which conforms to ISO, DIN, CIE, and ASTM standards. Reflectance Measurement-The CM-3600d employs d/8° geometry (diffused lighting, 8° from normal viewing) which conforms to JlS7 ISO, DIN, CIE and ASTM standards. Reliability High reliability design with fewest moving parts of any benchtop spectrophotometer Konica Minolta Innovative Optical System Technology Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before. CM-3610d Vertical Model Multiple measurement area selection To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25. 4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens. 2. Numerical UV Control To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, which is also part of the CM-3610d: The measured values of two sequentially fired flashes, one with full UV energy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UV-activated fluorescence sample. To avoid triplet effect on FWA treated samples, the CM-3600d and CM-3610d can be set to Soft-Flash mode. Numerical UV Control technology makes faster, more effective and reliable measurements of FWA treated materials such as textiles, papers and detergents. Bright and clear sample viewing system The retro mirror's reflected and illuminated sample viewing screen minimizes fatigue and allows trouble-free sample observation. LAV 25. 4mm MAV 8mm SAV 4mm Compact but yet Powerful Behind the compact and spacesaving design, you'll find the skills of a top-class instrument with 6" large sphere and other functions so far only found in much larger and more expensive instruments. Designed to meet your highest ergonomic expectations The compact and space-saving body as well as all functions of the CM-3600d have been designed to ensure easy and fatigue-free operation in daily use. The bright mirror sample viewing system, the sample holder for up to A4 size samples with full 90° lock down, and the versatile Transmittance chamber for liquid or translucent samples are all just where you expect them to be for easy operation. Maintenance free technology and ruggedness concept The CM-3600d is equipped with maintenance-free technology and solid state components to withstand rugged conditions. The monolith polychromator unit assures highest durability and stability. With one exception (Observing Lens), the CM-3600d does not use any moving parts. Furthermore, each CM-3600d passes a hard endurance test program to comply with KONICA MlNOLTA's highest quality standards in accordance with ISO-9001. UV-adjusted data System Diagram Cell CM-A97 (2mm) Cell CM-A98 (10mm) only CM-3600d Cell Plastic Cell Plastic Cell Plastic Cell CM-A99 CM-A130 CM-A131 CM-A132 (20mm) (2mm; set for 100) (10mm; set for 100) (20mm; set for 100) Personal Computer RS-232C Cable IF-A12 (for IBM PC) RS-232C Cables IF-A13 to IF-A15 Target Mask CM-A107 ( 4mm) Transmittance Specimen Holder CM-A96 Transmittance. Zero Calibration Plate CM-A100 Unit Driver SpectraMagic NX CM-A108 CM-S100w TM Target Mask CM-A106 ( 8mm) Spectrophotometer CM-3600d/CM-3610d AC Adapter AC-A12 AC Adapter AC-A21 (for Korea) Target Mask CM-A105 ( 25. 4mm) (with floppy disk containing calibration data) White Calibration Plate CM-A103 Standard accessories Zero Calibration Box CM-A104 CM-3600d Optional accessories Zero Calibration Box CM-A119 CM-3610d Dust Cover CM-A110 CM-A118 Opacity Jig Accessory Case CM-A134 CM-A109 only CM-3610d Color Tiles Specifications Illumination/ Observation system Reflectance;d/8 (diffused illumination, 8-degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded) Conforms to CIE No. 15, lSO7724/1, ASTME1164, DIN5033 Teil7 and JIS Z8722 condition C standard. Transmittance : d/0 (diffused illumination, 0-degree viewing) Conforms to CIE No. 15, ASTME1164 and DIN5033 Teil7 standard. [. . . ] Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Certificate No : YKA 0937154 Registration Date : March 3, 1995 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 ©2000 KONICA MINOLTA SENSING, INC. 9242-4868-31 AGMDPK 10 Printed in Japan [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CM3610D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CM3610D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag