[. . . ] DATA SHEET
MITEL
8568 Telephone
Ultimate Technology Professional Productivity
Compatible with the Mitel 5000 Communications Platform (CP), the new Mitel 8568 Telephone is perfect for users who require efficient call processing capabilities. [. . . ] Equipped with both speakerphone capability and a dedicated headset jack, the 8568 Telephone is designed to enhance productivity.
Unified Communications Support
When used with Mitel Unified Communicator® (UC) Express or Mitel Unified Communicator® (UC) Advanced Release 3. 0 applications, the 8568 Telephone becomes a powerful communications tool that helps customers streamline communications between people and organizations. This leads to improved productivity, enhanced customer service, reduced costs, and ultimately, improved business process integration.
Scalable Functionality
The 8568 Telephone integrates with the Mitel Programmable Key Module (PKM) 12 and Mitel Programmable Key Module (PKM) 48 for easy addition of quick access function keys.
8568 Telephone with PKM48
Features
· Six-line x 16-character alphanumeric display with eight, menu-driven, context-sensitive softkeys · 16 programmable multi-function keys with LED indicators · 10 hard function keys: Mute, Speaker, Volume Up / Down, Directory, Feature , Redial, Hold, Transfer, Message · Support for optional 12 and 48 button Programmable Key Modules · Handsfree operation (half-duplex) · Dedicated headset jack · Speed Calling (System / Station) · Intercom Calling · Emergency Calling · Call Hold (Place / Retrieve) · Call Transfer · Conference Calling · Call Waiting · Do Not Disturb · Call Forward (Manual / Automatic) · Voice mail notification large message waiting lamp · Message handling (View / Reply) · Direct page / Group page · Group Listen
· · · · · · ·
Last number redial Reminder Messages Call Logging (up to 20 entries) Store up to 10 station (personal) Speed Dial numbers Hearing Aid Compatible handset Wall mountable Two-position, 35 degree tilting stand for better viewing angle · 12-button Alpha / Numeric Dial Pad · Easily customize Do-Not-Disturb (DND) messages such as "In a meeting until 2:00, " "Leave a message" or "On Vacation Until"
Advanced Features
· Adjust Volume Levels: Provides multiple levels of volume for speaker, ringer, handset and headset · Select a Ring Tone · Enable Background Music · Enable Automatic Call Answer · Change the Display Language · Return Phone to Default Operation · Use Record-A-Call · Enable Paging · Place a Page Announcement · Program Feature Buttons · Program Direct Station Select (DSS) Keys · Program Secondary Extension Keys · Use Accounting Codes · Enter a Remote Access Password · Remote Feature Access
2 MITEL DATA SHEET
DATA SHEET
System Requirements
Mitel 5000 Communications Platform (CP), Release 3. 2
Regulatory Standards
EMC: CANADA: ICES-003 (CLASS B) USA: CFR Title 47, Part 15 (CLASS B) EU: EN55024: 1998 + A1: 2001 + A2:2003 EN55022: 2006 + A1: 2007 (Class B) EN 61000-3-2: 2006 EN 61000-3-3: 1995 + A1: 2001 + A2: 2005 EN 61000-4-2: Level 4 CANADA: CSA C22. 2 No. 60950-1 USA: UL 60950-1-07, Second Edition ANSI / NFPA 70, "National Electrical Code" EU: EN 60950: 2006
Maximum Loop Length
1200 ft (366 meters)
Environmental Conditions
Operational Storage Temperature +4°C to +49°C -40°C to +70°C Humidity 34% at +49°C, 95% at 29°C 15% at +70°C, 95% at 29°C Safety:
Telecom: CANADA: CS03 Part V (Hearing Aid Compatible) USA: FCC part 68 (CFR 47) (Hearing Aid Compatible) US Americans with Disabilities Act (ADA) (HAC & Volume Control)
8568 Telephone Specifications
Powering Phone Line powered from the digital loop interface PKM Output: 24 VDC Input: 110V 50-60Hz 220V 50Hz Consumption 1W Size (LxWxH): 9. 1" x 7. 5" x 3. 5" 23cm x 19cm x 9cm Weight: 1. 65 lbs 0. 75 kg MTBF Rate 10 Years
8568 TELEPHONE 3
Global Headquarters
Tel: +1(613) 592-2122 Fax: +1(613) 592-4784
U. S.
Tel: +1(480) 961-9000 Fax: +1(480) 961-1370
EMEA
Tel: +44(0)1291-430000 Fax: +44(0)1291-430400
CALA
Tel: +1(613) 592-2122 Fax: +1(613) 592-7825
Asia Pacific
Tel: +852 2508 9780 Fax: +852 2508 9232
www. mitel. com
For more information on our worldwide office locations, visit our website at www. mitel. com/offices
THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. The information furnished in this document, believed by Mitel to be accurate as of the date of its publication, is subject to change without notice. Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a result of having made this document available to you or based upon the information it contains. M MITEL (design) is a registered trademark of Mitel Networks Corporation. [. . . ] © Copyright 2010, Mitel Networks Corporation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MITEL 8568 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MITEL 8568 will begin.