Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MITSUBISHI DIAMOND PRO 900. We hope that this MITSUBISHI DIAMOND PRO 900 user guide will be useful to you.
Lastmanuals help download the user guide MITSUBISHI DIAMOND PRO 900.
Manual abstract: user guide MITSUBISHI DIAMOND PRO 900
Detailed instructions for use are in the User's Guide.
[. . . ] AUTO-SCANNING WITH DIGITAL CONTROL COLOR DISPLAY MONITOR
MITSUBISHI
MODEL NFJ9905SKHUW USER'S GUIDE
For future reference, record the serial number of your display monitor in the space below: SERIAL No. The serial number is located on the rear cover of the monitor.
ENGLISH
CAUTION
The power cord provided with this monitor is designed for safety and must be used with a properly grounded outlet to avoid possible electrical shock. Do not remove the monitor cabinet as this can expose you to very high voltages and other hazards. ANMERKUNG: Dieser Monitor erfüllt die Anforderungen der deutschen Ergonomie-Norm ZH1/ 618/10. 80 bei Verwendung der beiden folgenden Timing: Auflösung Videoeingang 1280x1024 Analog RGB, 0. 7Vs-s fH(kHz) fv(Hz) Interlace/Non-Interlace 91. 1 85. 0 Non-Interlaced
Aus ergonomischen Gründen wird empfohlen, die Grundfarbe Blau nicht auf dunklerem Untergrund zu verwenden (schlechte Erkennbarkeit, Augenbelastung bei zu geringem Zeichenkontrast). [. . . ] HD
VD
(2) IN CASE OF EXTERNAL COMPOSITE SYNC SIGNAL: Connect the R, G and B video signals and the Composite sync signal to BNC receptacles on rear panel, respectively.
D-SUB
BNC R G B
COMP. HD
VD
(3) IN CASE OF SEPARATE HORIZONTAL AND VERTICAL SYNC SIGNALS: Connect the R, G and B video signals and the horizontal and vertical sync signals to the BNC receptacles on the rear panel.
D-SUB
BNC R G B
COMP. HD
VD
- 1-15 -
ENGLISH
3. 3
USB System Basic Application
FRONT
BACK
D-SUB
BNC R G B
COMP. HD
VD
Upstream Ports Downstream Port
A B 1 2
R G D-SUB BNC B COMP. HD VD
Downstream Ports
Scanner
Keyboard
Camera
Computer
NOTE
The computer is required to have Windows 98 installed and USB functions. When connecting one computer, either Upstream port A or B is available. The Upstream port with that the computer is connected is detected automatically.
- 1-16 -
ENGLISH
CAUTION
Use the included ferrite core with the USB cable which is connected to the USB connectors (Downstream) to reduce the possibility of causing interference to radio, television, and other electrical devices.
D-SUB
BNC
A
B
1 2
R
G
B
COMP. HD
VD
USB CONNCTOR (DOWNSTREAM) USB CABLE FERRITE CORE
1 2
HOW TO MOUNT THE FERRITE CORE
Place the included ferrite core under the USB cable at approx. Then, close the plastic case until you have a clock.
USB Cable USB Plug Ferrite Core Approx. (3 cm)
- 1-17 -
ENGLISH
3. 4
1. 2.
Installation of USB Function
Power on the display monitor and computer. Enumerate Mitsubishi USB HUB using the following procedure.
NOTE
During the enumeration of Mitsubishi USB Hub, connect the keyboard and mouse equipped with USB function, to the computer and not to the downstream ports on the display monitor. After the enumeration, the keyboard and mouse can be used by connecting to the downstream ports. (1) Insert the included floppy disk in the computer. (2) Connect the computer and the display monitor with the included USB upstream cable. (3) Install 'INF' file from the included floppy disk. (4) Click "Next" on Figure 8 to get Figure 9. (5) Click "Finish" on Figure 9 to complete the enumeration of Mitsubishi USB HUB. You can confirm that "Mitsubishi USB HUB" is successfully enumerated with the following method. · Open "Device Manager" tab in "System" property under "Control Panel". Confirm that "Mitsubishi USB Hub" or "Generic USB HUB" is listed in "Universal Serial Bus Controller". If you can't confirm it, re-enumerate "Mitsubishi USB HUB" again by following (a) or (b). [. . . ] This sound will be heard each time the monitor is powered up from a cold start and each time the manual degauss button is used.
·
- 1-34 -
6
SPECIFICATIONS
ENGLISH
50cm/19"(46cm/18" Diagonal Viewable Image) Aperture grille In-line 90° Red, Green, Blue EBU (medium short persistence) 0. 25 - 0. 27mm (variable) Anti-glare, Anti-reflection and Anti-static coating Dynamic Beam Forming (DBF) 0. 7 or 1. 0Vp-p analog RGB Sync. or Composite sync 5BNC, DB9-15P 75 (video), 1k (sync. ) Self-powered HUB complying with Universal Serial Bus Specification Rev. 1. 0. USB Monitor Control to adjust the image on USB screen by USB commands from the computer. Interface 3 Downstream ports/12Mbps, 1. 5Mbps, possible to supply 500mA max. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI DIAMOND PRO 900
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI DIAMOND PRO 900 will begin.