Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MITSUBISHI MFZ-KA35VA. We hope that this MITSUBISHI MFZ-KA35VA user guide will be useful to you.
Lastmanuals help download the user guide MITSUBISHI MFZ-KA35VA.
Manual abstract: user guide MITSUBISHI MFZ-KA35VASERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS
No. OB409
SERVICE MANUAL
Wireless type Models
MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA -
E1
E1
E1
CONTENTS
1. PART NAMES AND FUNCTIONS······················2 2. SPECIFICATION·················································4 MFZ-KA25VA - E1 3. [. . . ] A-1.
Indoor fan motor (Lower) (MF2) Damper lock motor Right (ML1)
Check 9-6. Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C) Color of the lead wire BRN-other one Normal 235" ~ 255" Abnormal Open or short-circuit
Damper lock motor Left (ML2)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C) Color of the lead wire BRN-other one Normal 235" ~ 255" Abnormal Open or short-circuit
RED ROTOR YLW BRN ORN GRN
Horizontal vane motor(MV1)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C) Color of the lead wire BRN-other one Normal 235" ~ 255" Abnormal Open or short-circuit
Horizontal vane motor(MV2)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C) Color of the lead wire BRN-other one Normal 282" ~ 306" Abnormal Open or short-circuit
26
9-6. Troubleshooting flow
When the left lamp of OPERATION INDICATOR lamp flashes 3 times and the right lamp of OPERATION INDICATOR lamp is not lighted. Check of indoor fan motor (upper)
The indoor fan motor error has occurred, and the indoor fan doesn't operate.
Turn OFF the power supply.
Pay careful attention to the high voltage on the fan motor connector CN211. Turn ON the power supply, wait 5 seconds or more, and then press EMERGENCY OPERATION switch. Measure the supply voltage as follows within 12 seconds after EMERGENCY OPERATION switch is pressed. If more than 12 seconds passes by, turn OFF the power supply and turn ON it again, then measure the voltage. w 1) Measure the voltage between CN211 1(+) and 3(-). 2) Measure the voltage between CN211 5(+) and 3(-). wIf more than 12 seconds passes after EMERGENCY OPERATION switch is pressed, the voltage mentioned in above 2) goes 0V DC although the indoor electronic control P. C. board is normal.
Is there anything that interferes the rotation of the line flow fan?
No
Yes Remove the object and adjust the line flow fan.
Is there 311V DC between CN211 1 (+) and 3 (-), and does the voltage between CN211 5(+) and 3(-) rise to the range between 3 and 6V DC within 12 seconds after EMERGENCY OPERATION switch is pressed?No
Yes
Indoor electronic control P. C. Board
Replace the indoor fan motor. Fuse (F11)
JR05 JR06
VARISTOR (NR11)
IC101
CN1X1 CN1Y1
R111 Replace the indoor electronic control P. C. board.
C111T11
CN151 CN152 CN211 CN212
The indoor fan motor error has occurred, and the indoor fan repeats "12-second ON and 30-second OFF" 3 times, and then stops. No (Changed) Replace the indoor electronic control P. C. board.
Measure the voltage between CN211 6(+) and 3(-) while the fan motor is rotating.
Is 0V DC or 15V DC held unchanged?Yes (Unchanged) Replace the indoor fan motor.
27
When the left lamp of OPERATION INDICATOR lamp flashes 3 times and the right lamp of OPERATION INDICATOR lamp flashes ON and OFF every 0. 5-second. Check of indoor fan motor (lower)
The indoor fan motor error has occurred, and the indoor fan doesn't operate.
Turn OFF the power supply.
Pay careful attention to the high voltage on the fan motor connector CN212. [. . . ] (Refer to 1. ) (2) Remove the nozzle assembly (lower) and the drain hose. (Refer to 6. ) (3) Remove the screw of the ground wire of the indoor fan motor (lower), and then the ground wire. (See Photo 13. ) (4) Remove the screw of the motor band, and then the motor band. (See Photo 13. ) (5) Remove the line flow fan and the indoor fan motor (lower) from the box. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI MFZ-KA35VA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI MFZ-KA35VA will begin.