User manual MITSUBISHI PC30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MITSUBISHI PC30. We hope that this MITSUBISHI PC30 user guide will be useful to you.

Lastmanuals help download the user guide MITSUBISHI PC30.


Mode d'emploi MITSUBISHI PC30
Download

You may also download the following manuals related to this product:

   MITSUBISHI PC30 MANUAL 2 (880 ko)

Manual abstract: user guide MITSUBISHI PC30

Detailed instructions for use are in the User's Guide.

[. . . ] Air-Conditioners PLH18, 24, 30, 36, 42AK PL12, 18, 24, 30, 36, 42AK PCH24, 30, 36, 42EK PC24, 30, 36, 42EK PKH18, 24, 30, 36FK PK12, 18, 24, 30, 36FK FOR USER OPERATION read this operation manual thoroughly before operating the air-conditioner unit. MANUAL For safe and correct use, please Contents 1. Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · When the angle setting is C in cooling mode, switching the fan speed from HIGH to LOW will cause the angle to revert to B automatically. · The airflow direction can not be set with UP/DOWN while the SWING setting is being used. AIR SWEEP (PCH24, 30, 36, 42EK and PC24, 30, 36, 42EK only) 2 Press the AIR SWEEP button to turn the jumbo swing louver on or off. · Remote control display reading when air sweep is in operation. ON/OFF ­ CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN °F NOT AVAILABLE MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER AIR SWEEP CHECK SET TEMP. REMOTE CONTROLLER TIMER SET TEST RUN · The arrow indicators are alternately displayed when the air sweep is in operation, however they are not displayed when the air sweep is not in operation. · The airflow vane of the PCH series and the guide vane of the PKH and PK series can be changed manually. 12 BA 2. 6. Using the timer 1) Set the current time 1 Press clock/timer button to display the "CLOCK" B. ON/OFF ­ AUTO START AUTO No Display STOP CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN Remote controller display A CLOCK °F NOT AVAILABLE MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER 1 SET TEMP. REMOTE CONTROLLER AIR SWEEP CHECK TIMER SET TEST RUN 2 2 Each time you press TIMER SET button, the time increases in increments of one minute. TIMER SET Each time you press button, the time decreases in increments of one minute. · Press and hold the button to rapidly change the time. · The time changes in increments of one minute ten minutes in units of hour; in this order. · Approximately ten seconds after pressing the button, the display on the remote controller will turn off. A BC 2) Set the time to start the unit as follows 1 Press clock/timer button to display B 2 Press ON/OFF ­ TIMER SET AUTO START . button to set the time that you want the unit to start. The start time is displayed at A. CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN 3) Set the time to stop the unit as follows 1 Press clock/timer button to display C 2 Press TIMER SET AUTO STOP °F NOT AVAILABLE . button to set the time that you want the unit to stop. The stop time is displayed at A. MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER 1 SET TEMP. REMOTE CONTROLLER AIR SWEEP CHECK 4) Changing the set times 2 1 Press clock/timer button to display the time (CURRENT, START, STOP) you want to change. · Do not wash the filters in hot water (above 120°F), as this may warp them. · Make sure that the air filters are always installed. Operating the unit without air filters can cause malfunction. Cleaning the indoor unit · Wipe the outside of the unit with a clean, dry, soft cloth. · Clean off any oil stains or finger marks using a neutral household detergent (such as dishwashing liquid or laundry detergent). Caution: Never use gasoline, benzene, thinner, scouring powder or any type of nonneutral detergent, as these substances may damage the unit's case. ON/OFF ­ CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN °F NOT AVAILABLE 5 3. Care and cleaning Clean the filter When the A "FILTER" indicator blinks on the remote controller to alert you to the necessity of cleaning of the filter. As a guideline for typical office environment, the long-life filter must be cleaned every 2, 500 (PL(H))/100 (PC(H), PK(H)) operating hours. ON/OFF ­ CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN Reset the FILTER indicator 1 Press the FILTER button twice after cleaning. [. . . ] Specifications Item Models PCH24EK 24, 000 27, 000 [33, 800/35, 500] 18, 400 [25, 200/26, 900] 2. 46 2. 42 [4. 42/4. 92] 2. 1 [4. 1/4. 6] 10. 3 7. 1 PCH24EK PCH30EK PCH36EK 30, 000 35, 400 33, 000 [39, 800/41, 500] 38, 000 [45, 900/47, 600] 20, 900 [27, 700/29, 400] 19, 600 [27, 500/29, 200] 3. 06 3. 53 3. 13 [5. 13/5. 63] 3. 4 [5. 7/6. 2] 2. 6 [4. 6/5. 51] 2. 7 [5. 0/5. 5] 10. 0 10. 4 7. 1 7. 4 PCH30EK PCH36EK Munsell 2. 5Y 8/0. 3 & N2 208/230, 1, 60 25 15 PCH42EK 42, 000 45, 000 [52, 900/54, 600] 24, 800 [32, 700/34, 400] 4. 37 4. 3 [6. 6/7. 1] 3. 2 [5. 5/6. 0] 10. 0 7. 3 PCH42EK Cooling *1 BTU/h Capacity Heating *1, *3 BTU/h Heating *2, *3 BTU/h Cooling *1 kW Power Heating *1, *3 kW consumption Heating *2, *3 kW SEER HSPF INDOOR UNIT MODELS External finish Power supply V, Phase, Hz Max. Auxiliary heater A (kW) Airflow Dry CFM Lo-Hi Wet CFM W in Dimensions D in H in Weight lbs OUTDOOR UNIT MODELS External finish Power supply V, Phase, Hz Max. Crankcase heater A (W) Refrigerant control Defrost method W in Dimensions D in H in Weight lbs REMOTE CONTROLLER Control voltage (by built-in transformer) NOTES: 20 12 0. 7 9. 8/10. 8 [2. 0/2. 5] 830-920 670-740 50-7/16 26-13/16 10-1/8 97 PUH24EK PUH30EK Munsell 5Y 7/1 208/230, 1, 60 30 20 0. 75+0. 75 NH41NAD 14. 0 73 0. 16/0. 17 (33/39) Capillary tube Reverse cycle 34-1/4 11-5/8 49-9/16 202 245 With indoor unit 246 38-3/16 13-9/16 NH47NAD 17. 5 87 22 PUH36EK 17 1. 3 10. 8/12. 0 [2. 3/2. 8] 990-1270 860-110 62-1/4 119 PUH42EK 20 16 0. 65+0. 65 NH33NBD 11. 5 54 40 27 0. 8+0. 8 NH569NXA 20 105 268 Indoor unit-remote controller DC12V, Indoor unit- outdoor unit DC12V *1 Rating conditions (cooling) ­ indoor: 80°F DB. 75°F WB (heating) ­ indoor: 70°F DB. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI PC30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI PC30 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag