User manual MOFFAT MGH701X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MOFFAT MGH701X. We hope that this MOFFAT MGH701X user guide will be useful to you.

Lastmanuals help download the user guide MOFFAT MGH701X.


Mode d'emploi MOFFAT MGH701X
Download
Manual abstract: user guide MOFFAT MGH701X

Detailed instructions for use are in the User's Guide.

[. . . ] GB GAS HOB MGH 701 Please read this instruction booklet before using the appliance Important Safety Information You MUST read hese warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950950 Installation This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. Remove all packaging before using the hob. Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. [. . . ] 480 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V~50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3 TYPE OF GAS BURNER RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN TRIPLE CROWN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm MAX MIN NATURAL GAS 20 mbar 2. 8 0. 65 2. 0 0. 45 1. 0 0. 33 4. 0 1. 2 0. 266 113 0. 062 Adjust. 0. 190 96 0. 043 Adjust. 0. 095 70 0. 028 Adjust. 0. 381 146 0. 114 Adjust. VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar 2. 8 0. 65 2. 0 0. 45 1. 0 0. 33 4. 0 1. 2 202 86 47 40 144 71 32 32 72 50 24 28 288 98 86 56 Burner Auxiliary Semi-rapid Rapid Triple Crown Dia. Tap By-pass 1/100 mm 28 32 40 56 APPLIANCE CLASS : 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas (2H) G20 / 20 mbar Aeration adjustment none This appliance complies with the following E. E. C. Directives: * 73/23 - 90/683 (Low VoltageDirective); * 93/68 (General Directives); * 89/336 (Electromagnetical Compatibility Directive); * 90/396 (Gas Appliances), and subsequent modifications 6 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE 600 mm Provision for ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. 700 mm 400 mm 55 mm 400 mm 100 mm 50 m m 50 m m FO 2369* FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 600 mm Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. 700 mm 400 mm 55 mm 400 mm 100 mm 50 m m 50 m m FO 2231* 7 Installation IMPORTANT: This hob must be installed by a competent person to the relevant Gas Standards. Any gas installation must be carried out by a competent person. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory. from the side edges, as shown in the diagram, taking care that the seals meet without overlapping; · place the hob in the cut out, taking care that it is centred; · fix the hob with the relevant fixing clamps and screws, as shown in the diagram. When the screws have been tightened, the excess seal can be removed. The edge of the hob forms a double seal which prevents the ingress of liquids. FO 2753 9 a Electrical connections Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations. The manufacturer declines any liability should these safety measures not be observed. [. . . ] However a detailed visual inspection should reveal evidence of burning around the fault. 11 Ignition System / Gas Ignition Ignitor does not spark YES Check gas supply at burner NO Check plug top fuse and replace if necessary Light burner manually Check polarity and earth continuity of supply point Check by pass simmer adjusted Check earth continuity of appliance Check position of the electrode Check continuity from 'N' on the mains connector block and "N" on the ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check fitting of burners Check continuity from 'L' on the mains connector block and the taps ignition switches Check for breaks in the insulation of the HT leads Check continuity from ignition switches connector to ignitor unit "L" Change the taps ignition switches Change the ignitor unit 12 Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. Turn the gas tap to the MAX position and ignite. Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below. Procedure: Re-ignite the burner and set to MIN. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MOFFAT MGH701X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MOFFAT MGH701X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag