[. . . ] GB
GAS HOB
MGH 701
Please read this instruction booklet before using the appliance
Important Safety Information
You MUST read hese warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950950
Installation
This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. Remove all packaging before using the hob. Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. [. . . ] 480 mm.
SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V~50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3
TYPE OF GAS
BURNER
RAPID (large) MAX MIN
SEMI-RAPID (medium) MAX MIN
AUXILIARY (small) MAX MIN
TRIPLE CROWN
POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm
MAX
MIN
NATURAL GAS 20 mbar
2. 8
0. 65
2. 0
0. 45
1. 0
0. 33
4. 0
1. 2
0. 266 113
0. 062 Adjust.
0. 190 96
0. 043 Adjust.
0. 095 70
0. 028 Adjust.
0. 381 146
0. 114 Adjust.
VALUE = 49. 92 MJ/Kg
LPG GAS 28-30/37 mbar
2. 8
0. 65
2. 0
0. 45
1. 0
0. 33
4. 0
1. 2
202 86
47 40
144 71
32 32
72 50
24 28
288 98
86 56
Burner Auxiliary Semi-rapid Rapid Triple Crown
Dia. Tap By-pass 1/100 mm 28 32 40 56
APPLIANCE CLASS : 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas (2H) G20 / 20 mbar
Aeration adjustment none
This appliance complies with the following E. E. C. Directives: * 73/23 - 90/683 (Low VoltageDirective); * 93/68 (General Directives); * 89/336 (Electromagnetical Compatibility Directive); * 90/396 (Gas Appliances), and subsequent modifications
6
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE
600 mm
Provision for ventilation
Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.
700 mm 400 mm
55
mm
400 mm
100
mm
50 m
m 50 m m
FO 2369*
FITTING THE GAS HOB WITH A COOKER HOOD ABOVE
600 mm
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.
700 mm
400 mm
55 mm
400 mm
100 mm
50 m
m 50 m m
FO 2231*
7
Installation
IMPORTANT: This hob must be installed by a competent person to the relevant Gas Standards. Any gas installation must be carried out by a competent person. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory. from the side edges, as shown in the diagram, taking care that the seals meet without overlapping; · place the hob in the cut out, taking care that it is centred; · fix the hob with the relevant fixing clamps and screws, as shown in the diagram. When the screws have been tightened, the excess seal can be removed. The edge of the hob forms a double seal which prevents the ingress of liquids.
FO 2753
9
a Electrical connections
Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations. The manufacturer declines any liability should these safety measures not be observed. [. . . ] However a detailed visual inspection should reveal evidence of burning around the fault.
11
Ignition System / Gas Ignition
Ignitor does not spark
YES
Check gas supply at burner
NO
Check plug top fuse and replace if necessary Light burner manually
Check polarity and earth continuity of supply point
Check by pass simmer adjusted
Check earth continuity of appliance
Check position of the electrode
Check continuity from 'N' on the mains connector block and "N" on the ignitor unit
Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit
Check fitting of burners
Check continuity from 'L' on the mains connector block and the taps ignition switches
Check for breaks in the insulation of the HT leads
Check continuity from ignition switches connector to ignitor unit "L"
Change the taps ignition switches
Change the ignitor unit
12
Commissioning
When the hob has been fully installed it will be necessary to check the minimum flame setting. Turn the gas tap to the MAX position and ignite. Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.
Procedure: Re-ignite the burner and set to MIN. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MOFFAT MGH701X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.