User manual NAPCO C 200 AP DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO C 200 AP. We hope that this NAPCO C 200 AP user guide will be useful to you.

Lastmanuals help download the user guide NAPCO C 200 AP.


Mode d'emploi NAPCO C 200 AP
Download
Manual abstract: user guide NAPCO C 200 APDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Each time the sensors detect a stimulus stong enough to generate a signal, but insufficient in strength to indicate an alarm, the detector will automatically change sensitivity modes, effectively widening the gap between the detected signal and its alarm threshold. Therefore, environmental disturbances, those that register by the PIR and/or microwave sensor, are better tolerated and the threat of false alarms or nuisance alarms is dramatically reduced, far surpassing the performance of conventional dual technology devices. Napco Adaptive® C200AP also includes P. E. T. [. . . ] The on-board A to D conversion microprocessor (Analog-to-Digital) analyzes all incoming microwave and PIR detected signals against its built in library of waveform signatures of known false alarm sources, like heaters, fans, blowing drapes/ blinds and animals. The product of decades of sensor engineering and expertise, this inherent signal processing intelligence, enables Adaptive® Detectors provides unsurpassed false alarm discrimination the reliability and accuracy will save both time and money. · P. E. T. TM - Profile Enhanced Targeting for revolutionary 100lb. Intelligently distinguishes animals, when present, from intruders; then automatically resensitizes when pets vacate protected areas. · 12 automatically-selected, dynamic Adaptive® detection modes for optimal "intruder catch" and stability. (Modes 1-12: 1 most sensitive, 12 most stable). · Dual technology microwave and PIR signal verification. The detector combines the strengths of both heat- and motion-sensitive detection technologies to dually verify alarm conditions for ideal false alarm discrimination. · "Smarter System" Panel and Sensor Integration Input: Automatically coordinates sensor sensitivity with panel status (armed, disarmed, arming in process, etc. ) · Active, automatic self-testing of all key components and circuits. The unit will internally generate both a PIR signal and a microwave signal, in intervals of 11- 16 hours, which will fully test both channels independently. Any failure or internal trouble will be reported to the system for quick remedy, avoiding any false sense of security or breach thereof. · Superior RFI-/EFI-/lightning shielded protection. Key components and resilient SMD circuitry are electronically-shielded to 30V/m. This protects the unit's proper performance from nuisance interference due to static discharge, power surges, electric spikes, etc. · 2 Vari-Pet field-changeable lenses supplied for application optimized field-of-view. Napco's custom-engineered aspheric fresnel lenses are carefully designed to provide the ideal wide angle lens array and are easily-aimable during installation. [. . . ] This includes properties of its circuitry and fresnel optics, which include integral extra white light protection, a Napco-pioneered innovation. · Compliances: UL, CUL, CE, INCERT, NFA2P, NCP SPECIFICATIONS · 40' x 40' (10. 6m2) Maximum Range (dependent upon Vari-Pet Lens Installed) · Operating Temperature: -10 to +50 degrees C (14 to 122 degrees F) · Mounting: · Output Relay: · Relay Time: · Alarm Relay: · Trouble: · Status Input: · Self-Test Interval: · Power Supply: · Current Drain: · Microwave: · Dimensions: · Shipping Weight: Wall or Corner, 7 to 8' maximum Form A; Normally Closed Approx. 4 seconds 100mA, 24Vdc w/internal 10 ohm current-limiting resistor Open collector current sinking with 39 ohm current limiting resistor, 20mA, max Panel disarmed, >5V armed, <1. 5V 11-16 hours Filtered 12Vdc Idle 33mA; Alarm 35mA 10. 525GHz ± 25MHz 4. 5H x 2. 5W x 2. 3"D (11. 4x6. 4 x 5. 8 cm) 7 oz. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO C 200 AP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO C 200 AP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag